Abstract
This article reports a recent study on the application of a two-phase closed thermosyphon (TPCT) in a thermosyphon for economizer (TPEC). The TPEC had three sections of equal size; the evaporator, the adiabatic section, and the condenser, of 250 mm × 250 mm × 250 mm (W × L × H). The TPCT was a steel tube of 12.7-mm ID. The filling ratios chosen to study were 30, 50, and 80% with respect to the evaporator length. The volumetric flow rates for the coolant (in the condenser) were 1, 2.5, and 5 l/min. Five working fluids investigated were: water, water-based silver nanofluid with silver concentration 0.5 w/v%, and the nanofluid (NF) mixed with 0.5, 1, and 1.5 w/v% of oleic acid (OA). The operating temperatures were 60, 70, and 80°C. Experimental data showed that the TPEC gave the highest heat flux of about 25 kW/m2 and the highest effectiveness of about 0.3 at a filling ratio of 50%, with the nanofluid containing 1 w/v% of OA. It was further found that the effectiveness of nanofluid and the OA containing nanofluids were superior in effectiveness over water in all experimental conditions came under this study. Moreover, the presence of OA had clearly contributed to raise the effectiveness of the nanofluid.Keywords
This publication has 21 references indexed in Scilit:
- Thermosyphon installation for energy thrift in a smoked fish sausage oven (TISO)Energy, 2010
- Heat transfer characteristics of a two-phase closed thermosyphon using de ionized water mixed with silver nanoHeat and Mass Transfer, 2009
- Investigation on the effect of filling ratio on the steady-state heat transfer performance of a vertical two-phase closed thermosyphonApplied Thermal Engineering, 2008
- Thermal diffusivity measurements of metastable austenite during continuous coolingInternational Journal of Thermal Sciences, 2008
- Thermal characteristics of a thermosyphon heated enclosureInternational Journal of Thermal Sciences, 2006
- Heat transfer characteristics of a two-phase closed thermosyphonApplied Thermal Engineering, 2005
- Performance of a two-phase closed thermosyphon solar collector with a shell and tube heat exchangerApplied Thermal Engineering, 2004
- Thermal applicability of two-phase thermosyphons in cooking chambers––experimental and theoretical analysisApplied Thermal Engineering, 2004
- Correlations to predict heat transfer characteristics of an inclined closed two-phase thermosyphon at normal operating conditionsApplied Thermal Engineering, 2000
- Design, construction and testing of a thermosyphon heat exchanger for medium temperature heat recovery in bakeriesHeat Recovery Systems and CHP, 1995