Artifact‐free partial volume correction for 177 Lu‐PSMA SPECT
Authors:
Open Access
- 22 December 2025
- journal article
- Published by Wiley in Medical Physics
- Vol. 53 (1) , e70218
Abstract
Background: Partial volume effect degrades the quantification accuracy of SPECT across the field‐of‐view at varying extent. However, traditional partial volume corrections (PVCs) usually apply a spatially invariant point spread function and deconvolution‐based PVC may cause Gibbs ringing artifacts. Purpose: We aim to develop a spatially variant PSF (svPSF) enhanced PVC without Gibbs ringing artifact and noise amplification for 177 Lu‐PSMA SPECT. Methods: The svPSFs were generated through linear interpolations of Monte Carlo simulated 177 Lu point sources across the field‐of‐view. Reblurred Van Cittert (RVC) and iterative Yang (IY) were enhanced by applying svPSFs voxel by voxel. In RVC, the non‐negativity constraint (NC) was further implemented by scaling the negative values in the intermediate images with an empirical coefficient. All PVC methods were validated via simulated SPECT data using a digital geometrical cylindrical phantom with five spheres and 20 XCAT phantoms, as well as real sequential 177 Lu‐PSMA‐617 SPECT data of 10 clinical patients. Coefficient of variation (CoV) was measured on a uniform background on the geometrical phantom. Recovery coefficients (RC) of spheres and mean absolute activity errors (MAE) of the kidneys, parotid glands, and tumors in XCAT phantoms were evaluated, while the activity difference was evaluated in clinical data before and after PVC. Results: For the cylindrical phantom, the central sphere suffered from a more severe partial volume effect (RC of 0.50) than one of the peripheral spheres on the edge of the phantom (RC of 0.63). Their RCs were improved to 1.02 and 1.22 after IY, 1.03 and 0.98 after svPSF‐IY, 1.02 and 1.15 after RVC, 0.99 and 1.12 after NC‐RVC, and 0.98 and 1.01 after svPSF+NC‐RVC, respectively. The background CoV was 0.048 for non‐PVC, 0.090 for RVC, 0.078 for NC‐RVC, and 0.082 for svPSF+NC‐RVC. The MAEs of kidneys, parotid glands, and tumors before PVC were 20.4% ± 1.1%, 51.2% ± 6.1%, and 51.8% ± 8.1% respectively, and were best reduced to 4.7% ± 2.4%, 6.2% ± 4.5%, and 8.8% ± 6.4% after svPSF‐IY. The Gibbs ringing artifacts and noise in RVC were reduced when NC was implemented. The activity differences of clinical data showed a similar trend with those of XCAT simulations. Conclusions: The proposed svPSF enhanced PVC methods improve quantification accuracy in 177 Lu‐PSMA‐617 SPECT. NC suppresses the Gibbs ringing artifacts and reduces noise in standard RVC images.Keywords
Funding Information
- National Natural Science Foundation of China (82572278)
This publication has 15 references indexed in Scilit:
- Deep-Learning-Based Partial Volume Correction in 99m Tc-TRODAT-1 SPECT for Parkinson’s Disease: A Preliminary Study on Clinical TranslationIEEE Journal of Biomedical and Health Informatics, 2025
- Metastatic Castration-Resistant Prostate Cancer: Insights on Current Therapy and Promising Experimental DrugsResearch and Reports in Urology, 2023
- Partial volume effect in SPECT & PET imaging and impact on radionuclide dosimetry estimates.2023
- Radiation Dosimetry, Artificial Intelligence and Digital Twins: Old Dog, New TricksSeminars in Nuclear Medicine, 2022
- The effects of mismatch between SPECT and CT images on quantitative activity estimation – A simulation studyZeitschrift für Medizinische Physik, 2022
- Effects of voxel size and iterative reconstruction parameters on the spatial resolution of SPECT/CTJournal of Applied Clinical Medical Physics, 2011
- 4D XCAT phantom for multimodality imaging researchMedical Physics, 2010
- elastix: A Toolbox for Intensity-Based Medical Image RegistrationIEEE Transactions on Medical Imaging, 2009
- Investigation of Respiratory Gating in Quantitative Myocardial SPECTIEEE Transactions on Nuclear Science, 2009
- Metastatic patterns of prostate cancer: An autopsy study of 1,589 patientsHuman Pathology, 2000