Comparison of Inversion (“flipping”) Rates Among Different Port Designs: A Single-Center Experience
- 21 December 2016
- journal article
- research article
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 40 (4) , 553-559
Abstract
To compare incidence of port inversion among different types of implantable venous access devices. Records of patients who underwent imaging-guided subcutaneous port placement without port fixation between July 2001 and April 2015 were reviewed with use of a quality assurance database. 1930 patients with complete follow-up (death or explant) were included in the study. Collected data included date and indication for port placement, port type, venous access site, immediate and long-term complications, indication for removal, and total number of catheter days. BMI of patients with inverted ports was also calculated. Port inversion within the pocket was observed in 18 patients (0.9%) including 7/82 (9%) of Dignity ports, 4/126 (3%) of Vaxcel plastic arm ports, 3/142 (2%) of Smartports, 2/100 (2%) of Powerports, 1/14 (7%) of Vaccess ports, and 1/1421 (0.07%) of Vortex LP ports. Among these designs, the inversion rate was significantly lower in Vortex LP ports (0.1%) (P < 0.05). There was a trend toward higher inversion rate of Dignity ports, which have a rectangular design with a relatively narrow base. Mean dwell in inverted ports was 114 days (7–580). The incidence of port inversion without suture fixation of the port base to the pocket is extremely low. The present study shows differences in inversion incidence based on port design. Level of Evidence: Case Series, Level IV.Keywords
This publication has 13 references indexed in Scilit:
- Totally implantable venous access devices: retrospective analysis of different insertion techniques and predictors of complications in 796 devices implanted in a single institutionBMC Surgery, 2014
- Principles of Subcutaneous Port PlacementTechniques in Vascular and Interventional Radiology, 2011
- Venous Access Ports: Indications, Implantation Technique, Follow-Up, and ComplicationsCardioVascular and Interventional Radiology, 2011
- Implantable Subcutaneous Venous Access Devices: Is Port Fixation Necessary? A Review of 534 CasesCardioVascular and Interventional Radiology, 2009
- Relationship between Chest Port Catheter Tip Position and Port Malfunction after Interventional Radiologic PlacementJournal of Vascular and Interventional Radiology, 2004
- Society of Interventional Radiology Clinical Practice GuidelinesJournal of Vascular and Interventional Radiology, 2003
- Complications Associated With Implantable Vascular Access Devices in the Patient With CancerJournal of Infusion Nursing, 2003
- Risk of Deep Venous Thrombosis Associated with Chest versus Arm Central Venous Subcutaneous Port Catheters: A 5-Year Single-Institution Retrospective StudyJournal of Vascular and Interventional Radiology, 2002
- A Practical Approach for Repositioning Flipped Venous Access PortsJournal of Vascular and Interventional Radiology, 2000
- Peripheral Access OptionsSurgical Oncology Clinics of North America, 1995