Long-term multicentre studies are subject to numerous factors that may affect the integrity of their conclusions. Quality control and standardization of data collection are crucial to minimise the biases induced by these factors. Nevertheless, tools implemented to manage biases are rarely described in publications about population-based cohorts. This report aims to describe the processes implemented to control biases in the Constances cohort taking lung function results as an example. Constances is a general-purpose population-based cohort of 200,000 participants. Volunteers attend physical examinations at baseline and then every 5 years at selected study sites. Medical device specifications and measurement methods have to comply with Standard Operating Procedures developed by experts. Protocol deviations are assessed by on-site inspections and database controls. In February 2016, more than 94,000 participants yielding around 30 million readings from physical exams, had been covered by our quality program. Participating centres accepted to revise their practices in accordance with the study research specifications. Distributors of medical devices were asked to comply with international guidelines and Constances requirements. Close monitoring enhanced the quality of measurements and recordings of the physical exams. Regarding lung function testing, spirometry acceptability rates per operator doubled in some sites within a few months and global repeatability reached 96.7 % for 29,772 acceptable maneuvers. Despite Constances volunteers being followed in multiple sites with heterogeneous materials, the investment of significant resources to set up and maintain a continuous quality management process has proved effective in preventing drifts and improving accuracy of collected data.Keywords
Funding Information
- Agence Nationale de la Recherche (ANR-11-INBS-0002)
- CNAMTS
- Ministère des Affaires Sociales et de la Santé
- Conseil Régional, Île-de-France
- Iresp-ISP INSERM
- Ministère de l'Enseignement Supérieur et de la Recherche
- Inserm
- Institut National Du Cancer
- Caisse nationale de solidarité pour l'autonomie
This publication has 14 references indexed in Scilit:
- Impact of whole-body MRI in a general population studyEuropean Journal of Epidemiology, 2015
- The French CONSTANCES population-based cohort: design, inclusion and follow-upEuropean Journal of Epidemiology, 2015
- Detection of Outliers Due to Participants’ Non-Adherence to Protocol in a Longitudinal Study of Cognitive DeclinePLOS ONE, 2015
- Quality Assurance of Spirometry in a Population-Based Study –Predictors of Good Outcome in Spirometry TestingCOPD: Journal of Chronic Obstructive Pulmonary Disease, 2014
- Evaluation of Data Entry Errors and Data Changes to an Electronic Data Capture Clinical Trial DatabaseDrug Information Journal, 2011
- Technical and Functional Assessment of 10 Office SpirometersChest, 2006
- Standardisation of spirometryEuropean Respiratory Journal, 2005
- Repeatability of Spirometry in 18,000 Adult PatientsAmerican Journal of Respiratory and Critical Care Medicine, 2004
- Interviewer variability in anthropometric measurements and estimates of body compositionInternational Journal of Epidemiology, 1997
- Lung volumes and forced ventilatory flowsEuropean Respiratory Journal, 1993