Abstract
In Jordan, ~61% of total residential energy consumption is consumed by heating spaces using portable kerosene (K) and liquified petroleum gas (LPG) heaters. Here, we evaluated the indoor air quality (IAQ) versus the use of K and LPG heaters inside a test room reflecting the typical conditions of Jordanian dwellings during the winter season. The experimental setup included particle size distribution (diameter 0.01–25 µm) measurements, and we utilized a simple sectional indoor aerosol model (SIAM) to estimate the emission rate and lifetime of the combustion products in the test room. The particle number (PN) concentration during the LPG operation was 6 × 104–5.9 × 105 cm−3, depending on the setting at minimum, medium, or maximum. The K heater operation increased with the PN concentrations to a range of 4 × 105–8 × 105 cm−3. On average, the particle losses were 0.7–1.6 h−1 for micron particles (1–10 µm) and 0.8–0.9 h−1 for ultrafine particles (10–2.8 × 1010 particles/s (6.6 × 106–8.0 × 106 particles/J), and that for the K heater was about 4.4 × 1010 particles/s (1.9 × 107 particles/J). The results call for the immediate need to apply interventions to improve the IAQ by turning to cleaner heating processes indoors.
Funding Information
  • Deanship of Scientific Research at the University of Jordan (#2379, #WE-2-2-2017)
  • Scientific Research Support Fund at the Jordanian Ministry of Higher Education (#2379, #WE-2-2-2017)

This publication has 61 references indexed in Scilit: