Omar Al-Jaghbeer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Omar Al-Jaghbeer has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Tareq Hussein
Institute for Atmospheric and Earth System Research (INAR/Physics), Faculty of Science, University of Helsinki, FI-00014 Helsinki, Finland
2 shared publications - Bashar Lahlouh
Department of Physics, The University of Jordan, Amman 11942, Jordan
1 shared publication - Bilal Zidan
Department of Physics, School of Science, The University of Jordan, Amman 11942, Jordan
1 shared publication - Nizar Bqour
Department of Physics, School of Science, The University of Jordan, Amman 11942, Jordan
1 shared publication - Omar M. M. Nofal
Environmental and Atmospheric Research Laboratory (EARL), Department of Physics, School of Science, The University of Jordan, Amman 11942, Jordan
1 shared publication - Zaid Bakri
Michigan Technol Univ, Dept Phys, Atmospher Sci Program, Houghton, MI 49931 USA
1 shared publication
Latest Publications
- Open Access
- 27 July 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (8) , 1190
A Simple Parameterization to Enhance the Computational Time in the Three Layer Dry Deposition Model for Smooth Surfaces
Optimization of dry deposition velocity calculation has been of great interest. Every time, determining the value of the concentration boundary layer (CBL) thickness led to a waste of numerical calculation time, which appears as a huge time in large-scale climate models. The goal of this study is to optimize the numerical calculation time in the three-layer deposition model for smooth surfaces through the development of a MATLAB code that can parameterize the appropriate concentration boundary layer height (y+cbl) and internal integral calculation intervals for each particle diameter Dp (0.01–100 µm) and friction velocity u* (0.01–100 m/s). The particle concentration, as a solution to the particle flux equation, is obtained and modeled numerically by performing the left Riemann sum using MATLAB software. On the other hand, the number of subdivisions N of the Riemann sum was also parameterized for each Dp and in order to lessen the numerical calculation time. From a numerical point of view, the new parameterizations were tested by several computers; about 78% on the average of the computation time was saved when compared with the original algorithm. In other words, on average, about 1.2 s/calculation was gained, which is valuable in climate models simulations when millions of dry deposition calculations are needed.- 27 July 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (8) , 1190
Open AccessA Simple Parameterization to Enhance the Computational Time in the Three Layer Dry Deposition Model for Smooth Surfaces
Optimization of dry deposition velocity calculation has been of great interest. Every time, determining the value of the concentration boundary layer (CBL) thickness led to a waste of numerical calculation time, which appears as a huge time in large-scale climate models. The goal of this study is to optimize the numerical calculation time in the three-layer deposition model for smooth surfaces through the development of a MATLAB code that can parameterize the appropriate concentration boundary layer height (y+cbl) and internal integral calculation intervals for each particle diameter Dp (0.01–100 µm) and friction velocity u* (0.01–100 m/s). The particle concentration, as a solution to the particle flux equation, is obtained and modeled numerically by performing the left Riemann sum using MATLAB software. On the other hand, the number of subdivisions N of the Riemann sum was also parameterized for each Dp and in order to lessen the numerical calculation time. From a numerical point of view, the new parameterizations were tested by several computers; about 78% on the average of the computation time was saved when compared with the original algorithm. In other words, on average, about 1.2 s/calculation was gained, which is valuable in climate models simulations when millions of dry deposition calculations are needed. - Open Access
- 25 May 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (6) , 870
Exposure to Aerosols Emitted from Common Heating Combustion Sources Indoors—The Jordanian Case as an Example for Eastern Mediterranean Conditions
In Jordan, ~61% of total residential energy consumption is consumed by heating spaces using portable kerosene (K) and liquified petroleum gas (LPG) heaters. Here, we evaluated the indoor air quality (IAQ) versus the use of K and LPG heaters inside a test room reflecting the typical conditions of Jordanian dwellings during the winter season. The experimental setup included particle size distribution (diameter 0.01–25 µm) measurements, and we utilized a simple sectional indoor aerosol model (SIAM) to estimate the emission rate and lifetime of the combustion products in the test room. The particle number (PN) concentration during the LPG operation was 6 × 104–5.9 × 105 cm−3, depending on the setting at minimum, medium, or maximum. The K heater operation increased with the PN concentrations to a range of 4 × 105–8 × 105 cm−3. On average, the particle losses were 0.7–1.6 h−1 for micron particles (1–10 µm) and 0.8–0.9 h−1 for ultrafine particles (10–2.8 × 1010 particles/s (6.6 × 106–8.0 × 106 particles/J), and that for the K heater was about 4.4 × 1010 particles/s (1.9 × 107 particles/J). The results call for the immediate need to apply interventions to improve the IAQ by turning to cleaner heating processes indoors.
- 25 May 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (6) , 870
Open AccessExposure to Aerosols Emitted from Common Heating Combustion Sources Indoors—The Jordanian Case as an Example for Eastern Mediterranean Conditions
In Jordan, ~61% of total residential energy consumption is consumed by heating spaces using portable kerosene (K) and liquified petroleum gas (LPG) heaters. Here, we evaluated the indoor air quality (IAQ) versus the use of K and LPG heaters inside a test room reflecting the typical conditions of Jordanian dwellings during the winter season. The experimental setup included particle size distribution (diameter 0.01–25 µm) measurements, and we utilized a simple sectional indoor aerosol model (SIAM) to estimate the emission rate and lifetime of the combustion products in the test room. The particle number (PN) concentration during the LPG operation was 6 × 104–5.9 × 105 cm−3, depending on the setting at minimum, medium, or maximum. The K heater operation increased with the PN concentrations to a range of 4 × 105–8 × 105 cm−3. On average, the particle losses were 0.7–1.6 h−1 for micron particles (1–10 µm) and 0.8–0.9 h−1 for ultrafine particles (10–2.8 × 1010 particles/s (6.6 × 106–8.0 × 106 particles/J), and that for the K heater was about 4.4 × 1010 particles/s (1.9 × 107 particles/J). The results call for the immediate need to apply interventions to improve the IAQ by turning to cleaner heating processes indoors.