Observation of activity prior to dielectric breakdown in liquid xenon with the XeBrA experiment
Authors:
- J. WatsonJWJ. Watson
- E. E. DeckEDE. E. Deck
Preprint
Abstract
Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding one meter, requires a large negative voltage applied to their cathode. Delivering such high voltage is associated with an elevated risk of electrostatic discharge and electroluminescence, which would be detrimental to the performance of the TPC. The Xenon Breakdown Apparatus (XeBrA) is a five-liter high-voltage test chamber built to investigate the factors contributing to high voltage breakdown in noble liquids. Area scaling and surface finish were observed to be the dominant factors affecting breakdown. In addition, small electrical activity was frequently observed during high voltage ramps prior to electrostatic discharge. The position of breakdowns was reconstructed with a system of high-speed cameras and good agreement with electric field simulations was found. Based on the results presented in this work, we recommend that the next generation of TPCs should not withstand fields larger than 20 kV/cm on the electrode surfaces.Keywords
All Related Versions
This publication has 33 references indexed in Scilit:
- A study of DC electrical breakdown in liquid helium through analysis of the empirical breakdown field distributionsJournal of Applied Physics, 2021
- Influence of the experimental set-up and voltage ramp on the dielectric breakdown strength and breakdown site in borosilicate glassJournal of the European Ceramic Society, 2021
- Study and mitigation of spurious electron emission from cathodic wires in noble liquid time projection chambersAstroparticle Physics, 2018
- Formation mechanism of streamer discharges in liquids: a reviewHigh Voltage, 2016
- A simple high-sensitivity technique for purity analysis of xenon gasNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- Gap size effect on liquid helium breakdownCryogenics, 1994
- Examination of the statistics of dielectric breakdownJournal of Physics C: Solid State Physics, 1983
- Effect of an electric field on electron attachment to sulfur hexafluoride, nitrous oxide, and molecular oxygen in liquid argon and xenonThe Journal of Physical Chemistry, 1976
- Electrode area effect on the electric breakdown of liquid nitrogenCryogenics, 1974
- Die elektrische Festigkeit am Rande des PlattenkondensatorsElectrical Engineering, 1923