Three-dimensional drift correction of localised non-raster scanning on atomic force microscopy
- 12 August 2024
- journal article
- research article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (11) , 117003
Abstract
Non-raster scanning can increase the scanning frame rate and measurement speed of atomic force microscopes (AFMs). It is also possible to correct the 3D drift during the non-raster scanning. However, the algorithm for the drift correction depends upon the properties of each scan pattern. While localised non-raster scanning using a rosette scan may be faster than the frequently used Lissajous scanning patterns, the drift correction is more challenging because the scan has crossing points only in local neighbouring segments where there are short temporal and spatial separations of the crossing paths. This design note presents a novel solution that successfully overcomes this problem and extends a drift correction method previously developed for Lissajous scans to the 3D drift correction of localised non-raster scanning using a rosette scan trajectory. The drift in the X, Y and Z axes can be determined using the crossing points and locally repeated scans of the same features. The general procedure is presented together with experiments using rosette scans of a two-dimensional lateral calibration standard. Experimental results have demonstrated that the method can effectively correct both the drift in the three axes and sample tilt, leading to significantly improved images. The method requires only localised crossing points in the scan and does not need additional scans to determine the three-dimensional drift based on cross-correlation and least squares techniques, and it can be used with any AFMs capable of rosette scanning.Keywords
This publication has 12 references indexed in Scilit:
- Three-dimensional drift correction of scan data from atomic force microscopy using Lissajous scanning pathsMeasurement Science and Technology, 2021
- A reference-scan-based method for correcting the nonlinear drift of atomic force microscopy at sub-nanometer precisionMeasurement Science and Technology, 2020
- Rosette-scan video-rate atomic force microscopy: Trajectory patterning and control designReview of Scientific Instruments, 2019
- Gwyscan: a library to support non-equidistant scanning probe microscope measurementsMeasurement Science and Technology, 2017
- Height drift correction in non-raster atomic force microscopyUltramicroscopy, 2014
- Three-axis correction of distortion due to positional drift in scanning probe microscopyReview of Scientific Instruments, 2012
- Vertical and lateral drift corrections of scanning probe microscopy imagesJournal of Vacuum Science & Technology B, 2010
- Correction of distortion due to thermal drift in scanning probe microscopyUltramicroscopy, 2010
- Automatic drift elimination in probe microscope images based on techniques of counter-scanning and topography feature recognitionMeasurement Science and Technology, 2007
- An Updated Edlén Equation for the Refractive Index of AirMetrologia, 1993