Triaxial Micro Force Plate Array for Measuring Ground Reaction Force in Ant Locomotion
- 11 August 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (18) , 34480-34490
Abstract
Terrestrial insects, such as ants, are known for their agile locomotion on six legs. However, the ground reaction force (GRF) of each leg has not been well characterized due to its difficulty in measurement. In this report, a micro force plate array is presented that uses the sampling Moiré (SM) method, a prism, and a single camera to simultaneously measure the triaxial GRFs of multiple legs of an ant during its locomotion. The SM method is a high-resolution measurement method that measures the amount of displacement based on the shift of a captured grid pattern. The proposed micro force plate array consists of a $3 \times 3$ array of $2900 \times 2900 \times 70 \; \mu $ m plate bases with a gap of $100 \; \mu $ m as the contact surface of the ant legs. The plate base is supported by a spring structure with a grid pattern. By capturing this grid pattern from the backside via a prism, a camera can capture images from two different directions, allowing the triaxial displacement to be measured. By dividing the plate surface into nine sections and evaluating the error based on the position of the force application in the z-direction force, a maximum measurement error of 6% was found. The average force resolution in the x-, y-, and z-directions for the nine plates was 3.34, 2.47, and $1.20 \; \mu $ N, respectively. With the developed force plate array, it was possible to measure the GRF of each leg simultaneously while the ant was walking.
Keywords
Funding Information
- Keio Leading-Edge Laboratory of Science and Technology (KLL) Specified Research Projects
- Shotoku Science Foundation
- Keio University Doctorate Student Grant-in-Aid Program from Ushioda Memorial Fund 2024 (Y01JI24117)
- Japan Science and Technology Agency (JST) Support for Pioneering Research Initiated by the Next Generation (SPRING), Japan (JPMJSP2123)
- Grant-in-Aid for Scientific Research (25H00721)
- Grant-in-Aid for JSPS Fellows (25KJ2082)
This publication has 35 references indexed in Scilit:
- MEMS highly sensitive and large-area force plate for total ground reaction force measurement of running antJournal of Micromechanics and Microengineering, 2024
- Characterizing the measurement resolution and measurement bias of Sampling MoiréOptics and Lasers in Engineering, 2024
- Measuring Ground Reaction Force and Quantifying Variability in Jumping and Bobbing ActionsJournal of Structural Engineering, 2017
- MEMS two-axis force plate array used to measure the ground reaction forces during the running motion of an antJournal of Micromechanics and Microengineering, 2014
- Simultaneous detection of particles and airflow with a MEMS piezoresistive cantileverMeasurement Science and Technology, 2013
- Accuracy of the Sampling Moiré Method and its Application to Deflection Measurements of Large-Scale StructuresExperimental Mechanics, 2011
- Comparing inclined locomotion in a ground-living and a climbing ant species: sagittal plane kinematicsJournal of Comparative Physiology A, 2009
- Sampling Moiré Method for Accurate Small Deformation Distribution MeasurementExperimental Mechanics, 2009
- Mechanical models for insect locomotion: dynamics and stability in the horizontal plane I. TheoryBiological Cybernetics, 2000
- Similarity in multilegged locomotion: Bouncing like a monopodeJournal of Comparative Physiology A, 1993