Single-shot Talbot–Lau x-ray dark-field imaging of a porcine lung applying the moiré imaging approach
- 1 September 2018
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (18) , 185010
Abstract
Talbot–Lau x-ray imaging provides additionally to the conventional attenuation image, two further images: the differential phase-contrast image which is especially sensitive to differences in refractive properties and the dark-field image which is showing the x-ray scattering properties of the object. Thus, in the dark-field image sub-pixeled object information can be observed. As it has been shown in recent studies, this is of special interest for lung imaging. Changes in the alveoli structure, which are in the size of one detector pixel, can be seen in the dark-field images. A fast acquisition process is crucial to avoid motion artifacts due to heartbeat and breathing of the patient. Using moiré imaging the images can be acquired with a single-shot exposure. Nevertheless, the spatial resolution is reduced compared to the phase-stepping acquisition. We evaluate the results of both imaging techniques towards their feasibility in clinical routine. Furthermore, we analyse the influence of artificial linear object movement on the image quality, in order to simulate the heartbeat of a patient.Keywords
This publication has 44 references indexed in Scilit:
- Laboratory-based X-ray phase-imaging scanner using Talbot-Lau interferometer for non-destructive testingScientific Reports, 2017
- In-vivo dark-field and phase-contrast x-ray imagingScientific Reports, 2013
- Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase steppingMedical Physics, 2011
- A grating‐based single‐shot x‐ray phase contrast and diffraction method for in vivo imagingMedical Physics, 2010
- The Theory of the Moiré Phenomenon2009
- Artificial Thorax for MR Imaging Studies in Porcine Heart-Lung PreparationsRadiology, 2003
- Quantification of pneumothorax size on chest radiographs using interpleural distances: regression analysis based on volume measurements from helical CT.American Journal of Roentgenology, 1995
- New theoretical and experimental results in fresnel optics with applications to matter-wave and X-ray interferometryApplied Physics B, 1992
- Human Orcadian Rhythms in Resting and Exercise Pulse RatesErgonomics, 1977
- BEHAVIOR OF STROKE VOLUME AT REST AND DURING EXERCISE IN HUMAN BEINGS *Journal of Clinical Investigation, 1960