Veronika Ludwig
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Veronika Ludwig has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Gisela Anton
Erlangen Centre for Astroparticle Physics, Friedrich-Alexander-Universität Erlangen-Nürnberg, D-91058 Erlangen, Germany
27 shared publications - Thilo Michel
Friedrich Alexander Univ Erlangen Nurnberg, Erlangen Ctr Astroparticle Phys Ecap, Nikolaus Fiebiger Str 2, D-91058 Erlangen, Germany
11 shared publications - Florian Horn
Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Erlangen Centre for Astroparticle Physics, 91058, Erlangen, Germany
9 shared publications Georg Pelzer
Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Erlangen Centre for Astroparticle Physics, 91058, Erlangen, Germany
9 shared publications- Stephan Funk
Friedrich-Alexander Universität Erlangen-Nürnberg
9 shared publications - Bernhard Akstaller
Friedrich Alexander Univ Erlangen Nurnberg, Erlangen Ctr Astroparticle Phys Ecap, Nikolaus Fiebiger Str 2, D-91058 Erlangen, Germany
8 shared publications
Latest Publications
- Open Access
- 12 June 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (6) , 065413
Enhanced grating characterization method for absorbing x-ray gratings by bidirectional angular x-ray transmission
High-quality x-ray absorption gratings are essential for grating-based x-ray phase-contrast imaging. Bidirectional angular x-ray transmission (AXT) measurements, as proposed in this work, allow for large-area and nondestructive characterization of these gratings. A custom setup consisting of two rotational axes is used to measure the transmission of x-ray absorption gratings under rotation. From the transmission values and rotation angles, pixelwise transmission profiles are reconstructed. From these transmission profiles, parameter maps that carry information about the microstructure of the grating are retrieved via a fitting procedure. Compared to unidirectional AXT measurements, more detailed and complementary parameter maps are obtained, revealing more defects and parameter variations. Apart from duty cycle, absorber height, and absorber inclination, the bidirectional measurements also provide access to grating lamella rotation on the substrate and to auxiliary structures introduced to increase grating stability. Furthermore, a novel correction technique is introduced to address projective distortions in individual radiographs caused by the rotations. This method relies on calibration phantom measurements to track the movement of registration points under the same rotations as the gratings. Based on the movement of the registration points, the distortions are reconstructed, and appropriate deformation vector fields are calculated and applied to measurement data, achieving a correction with a precision of about two pixels.
- 12 June 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (6) , 065413
Open AccessEnhanced grating characterization method for absorbing x-ray gratings by bidirectional angular x-ray transmission
High-quality x-ray absorption gratings are essential for grating-based x-ray phase-contrast imaging. Bidirectional angular x-ray transmission (AXT) measurements, as proposed in this work, allow for large-area and nondestructive characterization of these gratings. A custom setup consisting of two rotational axes is used to measure the transmission of x-ray absorption gratings under rotation. From the transmission values and rotation angles, pixelwise transmission profiles are reconstructed. From these transmission profiles, parameter maps that carry information about the microstructure of the grating are retrieved via a fitting procedure. Compared to unidirectional AXT measurements, more detailed and complementary parameter maps are obtained, revealing more defects and parameter variations. Apart from duty cycle, absorber height, and absorber inclination, the bidirectional measurements also provide access to grating lamella rotation on the substrate and to auxiliary structures introduced to increase grating stability. Furthermore, a novel correction technique is introduced to address projective distortions in individual radiographs caused by the rotations. This method relies on calibration phantom measurements to track the movement of registration points under the same rotations as the gratings. Based on the movement of the registration points, the distortions are reconstructed, and appropriate deformation vector fields are calculated and applied to measurement data, achieving a correction with a precision of about two pixels.
- Open Access
- 20 June 2024
- Published by AIP Publishing in Matter and Radiation at Extremes
- Vol. 9 (4)
Demonstrating grating-based phase-contrast imaging of laser-driven shock waves
Single-shot X-ray phase-contrast imaging is used to take high-resolution images of laser-driven strong shock waves. Employing a two-grating Talbot interferometer, we successfully acquire standard absorption, differential phase-contrast, and dark-field images of the shocked target. Good agreement is demonstrated between experimental data and the results of two-dimensional radiation hydrodynamics simulations of the laser–plasma interaction. The main sources of image noise are identified through a thorough assessment of the interferometer’s performance. The acquired images demonstrate that grating-based phase-contrast imaging is a powerful diagnostic tool for high-energy-density science. In addition, we make a novel attempt at using the dark-field image as a signal modality of Talbot interferometry to identify the microstructure of a foam target.
- 20 June 2024
- Published by AIP Publishing in Matter and Radiation at Extremes
- Vol. 9 (4)
Open AccessDemonstrating grating-based phase-contrast imaging of laser-driven shock waves
Single-shot X-ray phase-contrast imaging is used to take high-resolution images of laser-driven strong shock waves. Employing a two-grating Talbot interferometer, we successfully acquire standard absorption, differential phase-contrast, and dark-field images of the shocked target. Good agreement is demonstrated between experimental data and the results of two-dimensional radiation hydrodynamics simulations of the laser–plasma interaction. The main sources of image noise are identified through a thorough assessment of the interferometer’s performance. The acquired images demonstrate that grating-based phase-contrast imaging is a powerful diagnostic tool for high-energy-density science. In addition, we make a novel attempt at using the dark-field image as a signal modality of Talbot interferometry to identify the microstructure of a foam target.
- Open Access
- 1 June 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (06) , E06004
ERRATUM: Design of a Talbot phase-contrast microscopy imaging system with a digital detector for laser-driven X-ray backlighter sources
- 1 June 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (06) , E06004
Open AccessERRATUM: Design of a Talbot phase-contrast microscopy imaging system with a digital detector for laser-driven X-ray backlighter sources
- Open Access
- 1 May 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (05) , P05004
Design of a Talbot phase-contrast microscopy imaging system with a digital detector for laser-driven X-ray backlighter sources
Laser-driven shock waves in matter propagate with multiple kilometers per second and therefore require sources like a laser-driven backlighter, which emit the X-rays within picoseconds, to be able to capture sharp images. The small spatial extent of shocks in low-density materials pose challenges on the imaging setup. In this work, we present a design process for a single-shot X-ray phase-contrast imaging system geared towards these objects, consisting of a two-grating Talbot interferometer and a digital X-ray detector. This imaging system is optimized with respect to the detectable refraction angle of the X-rays induced by an object, which implies a high phase sensitivity. Therefore, an optimization parameter is defined that considers experimental constraints such as the limited number of photons, the required magnification, the size and spectrum of the X-ray source, and the visibility of the moiré fringes. In this way, a large parameter space is sampled and a suitable imaging system is chosen. During a campaign at the PHELIX high-power laser facility a static test sample was imaged which is used to benchmark the optimization process and the imaging system under real conditions. The results show good agreement with the predicted performance, which demonstrates the reliability of the presented design process. Likewise, the process can be adapted to other types of laser experiments or X-ray sources and is not limited to the application presented here.
- 1 May 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (05) , P05004
Open AccessDesign of a Talbot phase-contrast microscopy imaging system with a digital detector for laser-driven X-ray backlighter sources
Laser-driven shock waves in matter propagate with multiple kilometers per second and therefore require sources like a laser-driven backlighter, which emit the X-rays within picoseconds, to be able to capture sharp images. The small spatial extent of shocks in low-density materials pose challenges on the imaging setup. In this work, we present a design process for a single-shot X-ray phase-contrast imaging system geared towards these objects, consisting of a two-grating Talbot interferometer and a digital X-ray detector. This imaging system is optimized with respect to the detectable refraction angle of the X-rays induced by an object, which implies a high phase sensitivity. Therefore, an optimization parameter is defined that considers experimental constraints such as the limited number of photons, the required magnification, the size and spectrum of the X-ray source, and the visibility of the moiré fringes. In this way, a large parameter space is sampled and a suitable imaging system is chosen. During a campaign at the PHELIX high-power laser facility a static test sample was imaged which is used to benchmark the optimization process and the imaging system under real conditions. The results show good agreement with the predicted performance, which demonstrates the reliability of the presented design process. Likewise, the process can be adapted to other types of laser experiments or X-ray sources and is not limited to the application presented here.
- Open Access
- 24 August 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8 (9) , 226
X-ray Dark-Field Imaging for Improved Contrast in Historical Handwritten Literature
If ancient documents are too fragile to be opened, X-ray imaging can be used to recover the content non-destructively. As an extension to conventional attenuation imaging, dark-field imaging provides access to microscopic structural object information, which can be especially advantageous for materials with weak attenuation contrast, such as certain metal-free inks in paper. With cotton paper and different self-made inks based on authentic recipes, we produced test samples for attenuation and dark-field imaging at a metal-jet X-ray source. The resulting images show letters written in metal-free ink that were recovered via grating-based dark-field imaging. Without the need for synchrotron-like beam quality, these results set the ground for a mobile dark-field imaging setup that could be brought to a library for document scanning, avoiding long transport routes for valuable historic documents.
- 24 August 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8 (9) , 226
Open AccessX-ray Dark-Field Imaging for Improved Contrast in Historical Handwritten Literature
If ancient documents are too fragile to be opened, X-ray imaging can be used to recover the content non-destructively. As an extension to conventional attenuation imaging, dark-field imaging provides access to microscopic structural object information, which can be especially advantageous for materials with weak attenuation contrast, such as certain metal-free inks in paper. With cotton paper and different self-made inks based on authentic recipes, we produced test samples for attenuation and dark-field imaging at a metal-jet X-ray source. The resulting images show letters written in metal-free ink that were recovered via grating-based dark-field imaging. Without the need for synchrotron-like beam quality, these results set the ground for a mobile dark-field imaging setup that could be brought to a library for document scanning, avoiding long transport routes for valuable historic documents.
- Open Access
- 15 March 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (3) , 794-806
Single-exposure X-ray phase imaging microscopy with a grating interferometer
The advent of hard X-ray free-electron lasers enables nanoscopic X-ray imaging with sub-picosecond temporal resolution. X-ray grating interferometry offers a phase-sensitive full-field imaging technique where the phase retrieval can be carried out from a single exposure alone. Thus, the method is attractive for imaging applications at X-ray free-electron lasers where intrinsic pulse-to-pulse fluctuations pose a major challenge. In this work, the single-exposure phase imaging capabilities of grating interferometry are characterized by an implementation at the I13-1 beamline of Diamond Light Source (Oxfordshire, UK). For comparison purposes, propagation-based phase contrast imaging was also performed at the same instrument. The characterization is carried out in terms of the quantitativeness and the contrast-to-noise ratio of the phase reconstructions as well as via the achievable spatial resolution. By using a statistical image reconstruction scheme, previous limitations of grating interferometry regarding the spatial resolution can be mitigated as well as the experimental applicability of the technique.
- 15 March 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (3) , 794-806
Open AccessSingle-exposure X-ray phase imaging microscopy with a grating interferometer
The advent of hard X-ray free-electron lasers enables nanoscopic X-ray imaging with sub-picosecond temporal resolution. X-ray grating interferometry offers a phase-sensitive full-field imaging technique where the phase retrieval can be carried out from a single exposure alone. Thus, the method is attractive for imaging applications at X-ray free-electron lasers where intrinsic pulse-to-pulse fluctuations pose a major challenge. In this work, the single-exposure phase imaging capabilities of grating interferometry are characterized by an implementation at the I13-1 beamline of Diamond Light Source (Oxfordshire, UK). For comparison purposes, propagation-based phase contrast imaging was also performed at the same instrument. The characterization is carried out in terms of the quantitativeness and the contrast-to-noise ratio of the phase reconstructions as well as via the achievable spatial resolution. By using a statistical image reconstruction scheme, previous limitations of grating interferometry regarding the spatial resolution can be mitigated as well as the experimental applicability of the technique.
- Open Access
- 5 September 2021
- Published by MDPI AG in Journal of Imaging
- Vol. 7 (9) , 178
Noise Reduction for Single-Shot Grating-Based Phase-Contrast Imaging at an X-ray Backlighter
X-ray backlighters allow the capture of sharp images of fast dynamic processes due to extremely short exposure times. Moiré imaging enables simultaneously measuring the absorption and differential phase-contrast (DPC) of these processes. Acquiring images with one single shot limits the X-ray photon flux, which can result in noisy images. Increasing the photon statistics by repeating the experiment to gain the same image is not possible if the investigated processes are dynamic and chaotic. Furthermore, to reconstruct the DPC and transmission image, an additional measurement captured in absence of the object is required. For these reference measurements, shot-to-shot fluctuations in X-ray spectra and a source position complicate the averaging of several reference images for noise reduction. Here, two approaches of processing multiple reference images in combination with one single object image are evaluated regarding the image quality. We found that with only five reference images, the contrast-to-noise ratio can be improved by approximately 13% in the DPC image. This promises improvements for short-exposure single-shot acquisitions of rapid processes, such as laser-produced plasma shock-waves in high-energy density experiments at backlighter X-ray sources such as the PHELIX high-power laser facility.
- 5 September 2021
- Published by MDPI AG in Journal of Imaging
- Vol. 7 (9) , 178
Open AccessNoise Reduction for Single-Shot Grating-Based Phase-Contrast Imaging at an X-ray Backlighter
X-ray backlighters allow the capture of sharp images of fast dynamic processes due to extremely short exposure times. Moiré imaging enables simultaneously measuring the absorption and differential phase-contrast (DPC) of these processes. Acquiring images with one single shot limits the X-ray photon flux, which can result in noisy images. Increasing the photon statistics by repeating the experiment to gain the same image is not possible if the investigated processes are dynamic and chaotic. Furthermore, to reconstruct the DPC and transmission image, an additional measurement captured in absence of the object is required. For these reference measurements, shot-to-shot fluctuations in X-ray spectra and a source position complicate the averaging of several reference images for noise reduction. Here, two approaches of processing multiple reference images in combination with one single object image are evaluated regarding the image quality. We found that with only five reference images, the contrast-to-noise ratio can be improved by approximately 13% in the DPC image. This promises improvements for short-exposure single-shot acquisitions of rapid processes, such as laser-produced plasma shock-waves in high-energy density experiments at backlighter X-ray sources such as the PHELIX high-power laser facility.
- Open Access
- 3 July 2020
- Published by MDPI AG in Journal of Imaging
- Vol. 6 (7) , 63
Evaluation of the Weighted Mean X-ray Energy for an Imaging System Via Propagation-Based Phase-Contrast Imaging
For imaging events of extremely short duration, like shock waves or explosions, it is necessary to be able to image the object with a single-shot exposure. A suitable setup is given by a laser-induced X-ray source such as the one that can be found at GSI (Helmholtzzentrum für Schwerionenforschung GmbH) in Darmstadt (Society for Heavy Ion Research), Germany. There, it is possible to direct a pulse from the high-energy laser Petawatt High Energy Laser for Heavy Ion eXperiments (PHELIX) on a tungsten wire to generate a picosecond polychromatic X-ray pulse, called backlighter. For grating-based single-shot phase-contrast imaging of shock waves or exploding wires, it is important to know the weighted mean energy of the X-ray spectrum for choosing a suitable setup. In propagation-based phase-contrast imaging the knowledge of the weighted mean energy is necessary to be able to reconstruct quantitative phase images of unknown objects. Hence, we developed a method to evaluate the weighted mean energy of the X-ray backlighter spectrum using propagation-based phase-contrast images. In a first step wave-field simulations are performed to verify the results. Furthermore, our evaluation is cross-checked with monochromatic synchrotron measurements with known energy at Diamond Light Source (DLS, Didcot, UK) for proof of concepts.
- 3 July 2020
- Published by MDPI AG in Journal of Imaging
- Vol. 6 (7) , 63
Open AccessEvaluation of the Weighted Mean X-ray Energy for an Imaging System Via Propagation-Based Phase-Contrast Imaging
For imaging events of extremely short duration, like shock waves or explosions, it is necessary to be able to image the object with a single-shot exposure. A suitable setup is given by a laser-induced X-ray source such as the one that can be found at GSI (Helmholtzzentrum für Schwerionenforschung GmbH) in Darmstadt (Society for Heavy Ion Research), Germany. There, it is possible to direct a pulse from the high-energy laser Petawatt High Energy Laser for Heavy Ion eXperiments (PHELIX) on a tungsten wire to generate a picosecond polychromatic X-ray pulse, called backlighter. For grating-based single-shot phase-contrast imaging of shock waves or exploding wires, it is important to know the weighted mean energy of the X-ray spectrum for choosing a suitable setup. In propagation-based phase-contrast imaging the knowledge of the weighted mean energy is necessary to be able to reconstruct quantitative phase images of unknown objects. Hence, we developed a method to evaluate the weighted mean energy of the X-ray backlighter spectrum using propagation-based phase-contrast images. In a first step wave-field simulations are performed to verify the results. Furthermore, our evaluation is cross-checked with monochromatic synchrotron measurements with known energy at Diamond Light Source (DLS, Didcot, UK) for proof of concepts.
- 21 April 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (9) , 13553-13568
Maximum likelihood reconstruction for grating-based X-ray microscopy
The combination of grating-based phase-contrast imaging with X-ray microscopy can result in a complicated image formation. Generally, transverse shifts of the interference fringes are nonlinearly dependent on phase differences of the measured wave front. We present an iterative reconstruction scheme based on a regularized maximum likelihood cost function that fully takes this dependency into account. The scheme is validated by numerical simulations. It is particularly advantageous at low photon numbers and when the premises for deconvolution-based reconstructions are not met. Our reconstruction scheme hence enables a broader applicability of X-ray grating interferometry in imaging and wave front sensing.
- 21 April 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (9) , 13553-13568
Maximum likelihood reconstruction for grating-based X-ray microscopy
The combination of grating-based phase-contrast imaging with X-ray microscopy can result in a complicated image formation. Generally, transverse shifts of the interference fringes are nonlinearly dependent on phase differences of the measured wave front. We present an iterative reconstruction scheme based on a regularized maximum likelihood cost function that fully takes this dependency into account. The scheme is validated by numerical simulations. It is particularly advantageous at low photon numbers and when the premises for deconvolution-based reconstructions are not met. Our reconstruction scheme hence enables a broader applicability of X-ray grating interferometry in imaging and wave front sensing.
- 1 January 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (1) , P01010
A phase-sampling method for an X-ray Talbot-Lau scanner with continuous grating movement
A Talbot-Lau scanner enables fast grating-based X-ray phase-contrast and dark-field imaging of large samples. We present a fast and robust scanning method based on continuous phase-sampling during the usual scan process. For that purpose the source grating is moved back and forth during the whole image acquisition procedure. The scanning method needs no specific detuning of the interferometer. The acquired images are compared to the results of a standard phase-stepping procedure. We show that high quality images are obtained by this continuous phase-sampling scanning method. One main advantage of the method is its independence of the occurring moire pattern shape, thus enabling an optimal alignment of the interferometer. Furthermore, the method works with a priori unknown phase-step positions. To our knowledge, this is the first time a grating is moved continuously back and forth while also the sample is in linear motion during a continuous image acquisition in Talbot-Lau imaging.
- 1 January 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (1) , P01010
A phase-sampling method for an X-ray Talbot-Lau scanner with continuous grating movement
A Talbot-Lau scanner enables fast grating-based X-ray phase-contrast and dark-field imaging of large samples. We present a fast and robust scanning method based on continuous phase-sampling during the usual scan process. For that purpose the source grating is moved back and forth during the whole image acquisition procedure. The scanning method needs no specific detuning of the interferometer. The acquired images are compared to the results of a standard phase-stepping procedure. We show that high quality images are obtained by this continuous phase-sampling scanning method. One main advantage of the method is its independence of the occurring moire pattern shape, thus enabling an optimal alignment of the interferometer. Furthermore, the method works with a priori unknown phase-step positions. To our knowledge, this is the first time a grating is moved continuously back and forth while also the sample is in linear motion during a continuous image acquisition in Talbot-Lau imaging.