Six Sigma-based assessment of critical cardiac biomarkers in the emergency laboratory
- 1 November 2026
- journal article
- Published by Bayrakol Medical Publishing in Journal of Clinical and Analytical Medicine
- Vol. 17 (11) , 1177-1181
Abstract
Aim Emergency laboratories require rapid, reliable test results to ensure patient safety, particularly for critical cardiac parameters. Six Sigma methodology offers an objective approach to assessing analytical performance by integrating precision, bias, and total allowable error. This study aimed to evaluate the analytical performance of high-sensitivity troponin T (Hs-TnT), creatine kinase-MB (CK-MB), and N-terminal pro–B-type natriuretic peptide (NT-proBNP) utilizing sigma metrics on two automated analyzers. Methods This study was conducted in the Clinical Biochemistry Laboratory of Ankara Etlik City Hospital using internal quality control (IQC) and external quality control (EQC) data collected between July and December 2024. Sigma metrics were calculated for Hs-TnT, CK-MB, and NT-proBNP on two Roche Cobas 8000 e801 analyzers. CV%, bias%, and TEa values (Clinical Laboratory Improvement Amendments [CLIA] 2025) were used to compute sigma. Quality goal index (QGI) was used to further explore sources of analytical error when sigma values were below 3. Results Hs-TnT demonstrated excellent performance (σ ≥ 6) on both analyzers at Level 2, while NT-proBNP showed excellent performance on Analyzer A at Level 1. No analyte exhibited poor performance (σ < 3) on either analyzer. CK-MB displayed adequate to good performance depending on the analyzer and control level. QGI results supported that none of the biomarkers showed error patterns indicative of critical analytical problems. Conclusion Hs-TnT, NT-proBNP, and CK-MB demonstrated acceptable-to-excellent analytical performance according to Sigma metrics, confirming their reliability in emergency laboratory settings. Sigma methodology is a fundamental approach for evaluating analytical performance, especially for critical tests. Ongoing assessment and verification ensure analytical quality and reliable results for clinical decision-making.Keywords
This publication has 21 references indexed in Scilit:
- Beyond the basics: Sigma scores in laboratory medicine with variable total allowable errors (TEa)Clinica Chimica Acta, 2024
- A Novel Approach for Routinely Assessing Laboratory Sigma Metrics for a Broad Range of Automated AssaysThe Journal of Applied Laboratory Medicine, 2024
- Comprehensive improvements in the emergency laboratory test process based on information technologyBMC Medical Informatics and Decision Making, 2023
- 2023 Focused Update of the 2021 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failureEuropean Heart Journal, 2023
- 2023 ESC Guidelines for the management of acute coronary syndromesEuropean Heart Journal, 2023
- Evaluation of Sigma value and quality goal index for brain natriuretic peptide testInternational Journal of Medical Biochemistry, 2020
- Sigma Metrics Across the Total Testing ProcessClinics In Laboratory Medicine, 2017
- Frequency that Laboratory Tests Influence Medical DecisionsThe Journal of Applied Laboratory Medicine, 2017
- The Effect of Laboratory Testing on Emergency Department Length of Stay: A Multihospital Longitudinal Study Applying a Cross‐classified Random‐effect Modeling ApproachAcademic Emergency Medicine, 2015
- Prioritizing Risk Analysis Quality Control Plans Based on Sigma-metricsClinics In Laboratory Medicine, 2013