Aziz Sener
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Aziz Sener has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Abdullah Uner
Department of Clinical Biochemistry, Ordu University Training and Research Hospital, T?rkiye
1 shared publicationArzu Kosem
Department of Clinical Biochemistry, Ankara Etlik City Hospital, T?rkiye
1 shared publication- Arzu Kösem
Department of Medical Biochemistry, Ankara Etlik City Hospital, Türkiye
1 shared publication Canan Topcuoglu
1 shared publication- Canan Topcuoglu
Department of Medical Biochemistry, Ankara Etlik City Hospital, 06170 Ankara, Turkey
1 shared publication - Elif Bengu Gungor Ay
Department of Medical Biochemistry, University of Health Sciences, Ankara Etlik City Hospital, Ankara, Türkiye
1 shared publication
Latest Publications
- 1 November 2026
- Published by Bayrakol Medical Publishing in Journal of Clinical and Analytical Medicine
- Vol. 17 (11) , 1177-1181
Six Sigma-based assessment of critical cardiac biomarkers in the emergency laboratory
Aim Emergency laboratories require rapid, reliable test results to ensure patient safety, particularly for critical cardiac parameters. Six Sigma methodology offers an objective approach to assessing analytical performance by integrating precision, bias, and total allowable error. This study aimed to evaluate the analytical performance of high-sensitivity troponin T (Hs-TnT), creatine kinase-MB (CK-MB), and N-terminal pro–B-type natriuretic peptide (NT-proBNP) utilizing sigma metrics on two automated analyzers. Methods This study was conducted in the Clinical Biochemistry Laboratory of Ankara Etlik City Hospital using internal quality control (IQC) and external quality control (EQC) data collected between July and December 2024. Sigma metrics were calculated for Hs-TnT, CK-MB, and NT-proBNP on two Roche Cobas 8000 e801 analyzers. CV%, bias%, and TEa values (Clinical Laboratory Improvement Amendments [CLIA] 2025) were used to compute sigma. Quality goal index (QGI) was used to further explore sources of analytical error when sigma values were below 3. Results Hs-TnT demonstrated excellent performance (σ ≥ 6) on both analyzers at Level 2, while NT-proBNP showed excellent performance on Analyzer A at Level 1. No analyte exhibited poor performance (σ < 3) on either analyzer. CK-MB displayed adequate to good performance depending on the analyzer and control level. QGI results supported that none of the biomarkers showed error patterns indicative of critical analytical problems. Conclusion Hs-TnT, NT-proBNP, and CK-MB demonstrated acceptable-to-excellent analytical performance according to Sigma metrics, confirming their reliability in emergency laboratory settings. Sigma methodology is a fundamental approach for evaluating analytical performance, especially for critical tests. Ongoing assessment and verification ensure analytical quality and reliable results for clinical decision-making.
- 1 November 2026
- Published by Bayrakol Medical Publishing in Journal of Clinical and Analytical Medicine
- Vol. 17 (11) , 1177-1181
Six Sigma-based assessment of critical cardiac biomarkers in the emergency laboratory
Aim Emergency laboratories require rapid, reliable test results to ensure patient safety, particularly for critical cardiac parameters. Six Sigma methodology offers an objective approach to assessing analytical performance by integrating precision, bias, and total allowable error. This study aimed to evaluate the analytical performance of high-sensitivity troponin T (Hs-TnT), creatine kinase-MB (CK-MB), and N-terminal pro–B-type natriuretic peptide (NT-proBNP) utilizing sigma metrics on two automated analyzers. Methods This study was conducted in the Clinical Biochemistry Laboratory of Ankara Etlik City Hospital using internal quality control (IQC) and external quality control (EQC) data collected between July and December 2024. Sigma metrics were calculated for Hs-TnT, CK-MB, and NT-proBNP on two Roche Cobas 8000 e801 analyzers. CV%, bias%, and TEa values (Clinical Laboratory Improvement Amendments [CLIA] 2025) were used to compute sigma. Quality goal index (QGI) was used to further explore sources of analytical error when sigma values were below 3. Results Hs-TnT demonstrated excellent performance (σ ≥ 6) on both analyzers at Level 2, while NT-proBNP showed excellent performance on Analyzer A at Level 1. No analyte exhibited poor performance (σ < 3) on either analyzer. CK-MB displayed adequate to good performance depending on the analyzer and control level. QGI results supported that none of the biomarkers showed error patterns indicative of critical analytical problems. Conclusion Hs-TnT, NT-proBNP, and CK-MB demonstrated acceptable-to-excellent analytical performance according to Sigma metrics, confirming their reliability in emergency laboratory settings. Sigma methodology is a fundamental approach for evaluating analytical performance, especially for critical tests. Ongoing assessment and verification ensure analytical quality and reliable results for clinical decision-making.
- Open Access
- 28 December 2025
- Published by MediHealth Academy in Academic Journal of Health
- Vol. 3 (3) , 94-97
Comparative Evaluation of Blood Gas and Biochemistry Analyzers in Lactate Measurement in Pediatric Patient Groups
Objective: Lactate plays an important role in clinical decision-making processes as an early biochemical marker of tissue hypoxia and hypoperfusion. The aim of this study is to compare lactate measurements obtained from blood gas and biochemistry analyzers in pediatric patients and to evaluate the clinical concordance between the methods. Methods: Pediatric cases with lactate measurements performed simultaneously on blood gas and biochemistry analyzers at the Ankara Etlik City Hospital Biochemistry Laboratory between January 2023 and August 2025 were retrospectively reviewed. A total of 914 paired lactate measurements were included in the analysis. Measurements were evaluated using Pearson correlation, Bland–Altman analysis, Passing–Bablok regression, and Cohen's kappa coefficient. A total allowable error (TEa) of ±0.20 mmol/L was considered the clinical acceptance criterion. Results: A very strong positive correlation was found between blood gas and biochemistry measurements (r = 0.95, p < 0.0001). In the Bland–Altman analysis, the mean bias was −0.13 mmol/L (95% CI: −0.18 to −0.08), the lower limit of agreement (LoA) was −1.56 mmol/L, and the upper LoA was 1.31 mmol/L; 95.1% of the results fell within these limits. The Passing–Bablok regression equation was y = 0.211 + 0.975·x (intercept 0.211, 95% CI: 0.168–0.251; slope 0.975, 95% CI: 0.954–0.996), and no deviation from linearity was observed (CUSUM p = 0.97). In the categorical analysis, the fit was good, with Cohen's kappa found to be 0.73 (95% CI: 0.70–0.76), and the misclassification rate remained below 10%. Conclusion: This study demonstrated that blood gas and biochemistry analyzers showed a high degree of agreement in lactate measurements in the pediatric patient group. The advantage of blood gas devices in providing rapid results is an important support element for clinicians, particularly in intensive care and emergency departments. Although minor differences were observed between the methods at low and high concentrations, it was determined that these differences were not significant enough to influence clinical decisions.
- 28 December 2025
- Published by MediHealth Academy in Academic Journal of Health
- Vol. 3 (3) , 94-97
Open AccessComparative Evaluation of Blood Gas and Biochemistry Analyzers in Lactate Measurement in Pediatric Patient Groups
Objective: Lactate plays an important role in clinical decision-making processes as an early biochemical marker of tissue hypoxia and hypoperfusion. The aim of this study is to compare lactate measurements obtained from blood gas and biochemistry analyzers in pediatric patients and to evaluate the clinical concordance between the methods. Methods: Pediatric cases with lactate measurements performed simultaneously on blood gas and biochemistry analyzers at the Ankara Etlik City Hospital Biochemistry Laboratory between January 2023 and August 2025 were retrospectively reviewed. A total of 914 paired lactate measurements were included in the analysis. Measurements were evaluated using Pearson correlation, Bland–Altman analysis, Passing–Bablok regression, and Cohen's kappa coefficient. A total allowable error (TEa) of ±0.20 mmol/L was considered the clinical acceptance criterion. Results: A very strong positive correlation was found between blood gas and biochemistry measurements (r = 0.95, p < 0.0001). In the Bland–Altman analysis, the mean bias was −0.13 mmol/L (95% CI: −0.18 to −0.08), the lower limit of agreement (LoA) was −1.56 mmol/L, and the upper LoA was 1.31 mmol/L; 95.1% of the results fell within these limits. The Passing–Bablok regression equation was y = 0.211 + 0.975·x (intercept 0.211, 95% CI: 0.168–0.251; slope 0.975, 95% CI: 0.954–0.996), and no deviation from linearity was observed (CUSUM p = 0.97). In the categorical analysis, the fit was good, with Cohen's kappa found to be 0.73 (95% CI: 0.70–0.76), and the misclassification rate remained below 10%. Conclusion: This study demonstrated that blood gas and biochemistry analyzers showed a high degree of agreement in lactate measurements in the pediatric patient group. The advantage of blood gas devices in providing rapid results is an important support element for clinicians, particularly in intensive care and emergency departments. Although minor differences were observed between the methods at low and high concentrations, it was determined that these differences were not significant enough to influence clinical decisions.
- Open Access
- 28 August 2024
- Published by Archives of Endocrinology and Metabolism in Archives of Endocrinology and Metabolism
- Vol. 68, e240004
Monocyte-to-HDL cholesterol ratio and uric acid-to-HDL cholesterol ratio as predictors of vitamin D deficiency in healthy young adults: a cross-sectional study
Objective This study aimed to assess vitamin D deficiency in a cohort of healthy young adults using the novel inflammatory parameters neutrophil-to-lymphocyte ratio (NLR), platelet-to-lymphocyte ratio (PLR), monocyte-to-lymphocyte ratio (MLR), monocyte-to-high-density lipoprotein (HDL) cholesterol ratio (MHR), and uric acid-to-HDL cholesterol ratio (UHR). Subjects and methods The study included 1,190 participants, with demographic and laboratory data retrieved retrospectively from our institution’s database. The inclusion criteria were ages 22-35 years; absence of acute, subacute, or chronic diseases; no regular medication use; [...] ABSTRACT Objective This study aimed to assess vitamin D deficiency in a cohort of healthy young adults using the novel inflammatory parameters neutrophil-to-lymphocyte ratio (NLR), platelet-to-lymphocyte ratio (PLR), monocyte-to-lymphocyte ratio (MLR), monocyte-to-high-density lipoprotein (HDL) cholesterol ratio (MHR), and uric acid-to-HDL cholesterol ratio (UHR). Subjects and methods The study included 1,190 participants, with demographic and laboratory data retrieved retrospectively from our institution’s database. The inclusion criteria were ages 22-35 years; absence of acute, subacute, or chronic diseases; no regular medication use;
- 28 August 2024
- Published by Archives of Endocrinology and Metabolism in Archives of Endocrinology and Metabolism
- Vol. 68, e240004
Open AccessMonocyte-to-HDL cholesterol ratio and uric acid-to-HDL cholesterol ratio as predictors of vitamin D deficiency in healthy young adults: a cross-sectional study
Objective This study aimed to assess vitamin D deficiency in a cohort of healthy young adults using the novel inflammatory parameters neutrophil-to-lymphocyte ratio (NLR), platelet-to-lymphocyte ratio (PLR), monocyte-to-lymphocyte ratio (MLR), monocyte-to-high-density lipoprotein (HDL) cholesterol ratio (MHR), and uric acid-to-HDL cholesterol ratio (UHR). Subjects and methods The study included 1,190 participants, with demographic and laboratory data retrieved retrospectively from our institution’s database. The inclusion criteria were ages 22-35 years; absence of acute, subacute, or chronic diseases; no regular medication use; [...] ABSTRACT Objective This study aimed to assess vitamin D deficiency in a cohort of healthy young adults using the novel inflammatory parameters neutrophil-to-lymphocyte ratio (NLR), platelet-to-lymphocyte ratio (PLR), monocyte-to-lymphocyte ratio (MLR), monocyte-to-high-density lipoprotein (HDL) cholesterol ratio (MHR), and uric acid-to-HDL cholesterol ratio (UHR). Subjects and methods The study included 1,190 participants, with demographic and laboratory data retrieved retrospectively from our institution’s database. The inclusion criteria were ages 22-35 years; absence of acute, subacute, or chronic diseases; no regular medication use;
- 1 January 2024
- Published by Kare Publishing in Eurasian Journal of Medical Advances
- Vol. 8 (2) , 199-206
The Effect of Vitamin D Deficiency on Platelet Indices in Various Anemia Groups
- 1 January 2024
- Published by Kare Publishing in Eurasian Journal of Medical Advances
- Vol. 8 (2) , 199-206
The Effect of Vitamin D Deficiency on Platelet Indices in Various Anemia Groups
- 20 November 2023
- Published by China Scientific Research Publishing Pte. Ltd. in JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS
- Vol. 37 (11) , 6005-6013
Association of New Inflammatory Markers with Diabetes Control and Albuminuria Levels in Type 2 Diabetes Mellitus Patients
Background: Recently, new inflammatory parameters obtained from complete blood count and biochemical measurements have gained importance. They are easy and inexpensive to perform. These parameters have been shown to have relationships with glycemic control and complications in diabetic patients in various studies. We aimed to compare new inflammatory markers [neutrophil to lymphocyte ratio (NLR), red cell distribution width (RDW), monocyte to lymphocyte ratio (MLR), monocyte to high-density lipoprotein ratio (MHR), platelet to lymphocyte ratio (PLR), and mean platelet volume (MPV)] among well-controlled and poorly controlled diabetic patient groups and also between albuminuria groups in Type 2 Diabetes Mellitus (T2DM) patients. Methods: We included 415 T2DM patients and analyzed them retrospectively. We divided the patients into well-controlled diabetics (hemoglobin A1C (HbA1c) ≤7%) and poorly-controlled diabetics (HbA1c >7%) to evaluate diabetic control. We also grouped patients in order to evaluate albuminuria as follows: A1: urine albumin-creatinine ratio (UACR) 300 mg/g. We compared the groups we formed based on diabetic control and albuminuria levels regarding new inflammatory markers and determined the correlation between these markers and HbA1c and UACR levels. Results: MHR showed a more remarkable and noticeable difference than other parameters when comparing A2 and A1 albuminuria group patients. Our study found that MLR was positively correlated with UACR measurements but not superior to other parameters that were positively correlated with UACR (p < 0.01). NLR and PLR differed significantly between the albuminuria groups and were positively correlated with UACR measurements (p < 0.01). RDW, on the other hand, did not show statistical differences between the albuminuria groups but was positively correlated with UACR measurements (p > 0.05, p < 0.01 respectively). MPV, neither statistically differed between the albuminuria groups nor showed correlation with UACR measurements (p > 0.05 for each). There was no difference in the results of new inflammatory markers between diabetes control groups, and there was no correlation with HbA1c measurements (p > 0.05 for each). Conclusions: These parameters are useful in assessing albuminuria in patients with T2DM, but not in assessing glycemic control.
- 20 November 2023
- Published by China Scientific Research Publishing Pte. Ltd. in JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS
- Vol. 37 (11) , 6005-6013
Association of New Inflammatory Markers with Diabetes Control and Albuminuria Levels in Type 2 Diabetes Mellitus Patients
Background: Recently, new inflammatory parameters obtained from complete blood count and biochemical measurements have gained importance. They are easy and inexpensive to perform. These parameters have been shown to have relationships with glycemic control and complications in diabetic patients in various studies. We aimed to compare new inflammatory markers [neutrophil to lymphocyte ratio (NLR), red cell distribution width (RDW), monocyte to lymphocyte ratio (MLR), monocyte to high-density lipoprotein ratio (MHR), platelet to lymphocyte ratio (PLR), and mean platelet volume (MPV)] among well-controlled and poorly controlled diabetic patient groups and also between albuminuria groups in Type 2 Diabetes Mellitus (T2DM) patients. Methods: We included 415 T2DM patients and analyzed them retrospectively. We divided the patients into well-controlled diabetics (hemoglobin A1C (HbA1c) ≤7%) and poorly-controlled diabetics (HbA1c >7%) to evaluate diabetic control. We also grouped patients in order to evaluate albuminuria as follows: A1: urine albumin-creatinine ratio (UACR) 300 mg/g. We compared the groups we formed based on diabetic control and albuminuria levels regarding new inflammatory markers and determined the correlation between these markers and HbA1c and UACR levels. Results: MHR showed a more remarkable and noticeable difference than other parameters when comparing A2 and A1 albuminuria group patients. Our study found that MLR was positively correlated with UACR measurements but not superior to other parameters that were positively correlated with UACR (p < 0.01). NLR and PLR differed significantly between the albuminuria groups and were positively correlated with UACR measurements (p < 0.01). RDW, on the other hand, did not show statistical differences between the albuminuria groups but was positively correlated with UACR measurements (p > 0.05, p < 0.01 respectively). MPV, neither statistically differed between the albuminuria groups nor showed correlation with UACR measurements (p > 0.05 for each). There was no difference in the results of new inflammatory markers between diabetes control groups, and there was no correlation with HbA1c measurements (p > 0.05 for each). Conclusions: These parameters are useful in assessing albuminuria in patients with T2DM, but not in assessing glycemic control.
- 1 August 2001
- Published by Spandidos Publications in International Journal of Molecular Medicine
- Vol. 8 (2) , 177-180
Assessment by D-[3H]mannoheptulose uptake of B-cell density in isolated pancreatic islets from Goto-Kakizaki rats
The uptake of D-[3H]mannoheptulose by isolated pancreatic islets was recently proposed as a tool to assess the relative contribution of insulin-producing cells to the total mass of the islets. In the present study, the uptake of the tritiated heptose over 60 min incubation at 37 degrees C was about 21% lower in islets from hereditarily diabetic rats (GK rats) than in islets from control animals, this decrease being virtually identical to that documented previously by morphometric analysis of islets from the same type of rats. The intracellular 3HOH space and extracellular [U-14C]sucrose space were not significantly different in control and diabetic rats, at least when the comparison was restricted to animals of the same sex. There was a trend, however, towards a somewhat lower D-[5-3H]-glucose intracellular distribution space in islets from GK rats, as compared to control animals. These findings provide further support to the validity of D-[3H]mannoheptulose uptake as a tool to assess the density of insulin-producing cells in isolated islets.
- 1 August 2001
- Published by Spandidos Publications in International Journal of Molecular Medicine
- Vol. 8 (2) , 177-180
Assessment by D-[3H]mannoheptulose uptake of B-cell density in isolated pancreatic islets from Goto-Kakizaki rats
The uptake of D-[3H]mannoheptulose by isolated pancreatic islets was recently proposed as a tool to assess the relative contribution of insulin-producing cells to the total mass of the islets. In the present study, the uptake of the tritiated heptose over 60 min incubation at 37 degrees C was about 21% lower in islets from hereditarily diabetic rats (GK rats) than in islets from control animals, this decrease being virtually identical to that documented previously by morphometric analysis of islets from the same type of rats. The intracellular 3HOH space and extracellular [U-14C]sucrose space were not significantly different in control and diabetic rats, at least when the comparison was restricted to animals of the same sex. There was a trend, however, towards a somewhat lower D-[5-3H]-glucose intracellular distribution space in islets from GK rats, as compared to control animals. These findings provide further support to the validity of D-[3H]mannoheptulose uptake as a tool to assess the density of insulin-producing cells in isolated islets.