Nonaqueous CE using contactless conductivity detection and ionic liquids as BGEs in ACN
- 17 October 2007
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 28 (20) , 3600-3605
Abstract
N,N′‐Alkylmethylimidazolium cations have been separated in NACE when one of the N,N′‐dialkylimidazolium salts (ionic liquids (ILs)) was used as an electrolyte additive to the organic solvent separation medium. The separated species were 1‐methyl‐, 1‐ethyl‐, 1‐butyl‐, 1‐octyl‐, 1‐decyl‐3‐methylimidazolium and N‐butyl‐3‐methylpyridinium cations and BGE composed of 1‐ethyl‐3‐methylimidazolium ethylsulfate or 1‐butyl‐3‐methylimidazolium trifluoroacetate [BMIm][FAcO] (A6; B2) diluted in ACN. It was demonstrated that contactless conductivity detection (CCD) may be applied to monitoring the separation process in nonaqueous separation media, allowing to use the UV light‐absorbing imidazolium‐based electrolyte additives. There could be marked three concentration regions of added ILs; at first ionic strength of BGE below 1–2 mM, and then the actual electrophoretic mobility of analytes rises from 0. At concentrations above 1–2 mM, the added IL facilitated separation. In concentration region of 1–20 mM, the actual electrophoretic mobility of analyzed imidazolium cations was increasing with decrease in separation medium ionic strength. At higher concentrations of BGE (above 30 mM), the conductivity of the separation media became too high for this detector. Some organic dyes were also successfully separated and detected by contactless conductivity detector in a 20 mM A6 separation electrolyte in ACN.Keywords
This publication has 25 references indexed in Scilit:
- Rapid electrophoretic separations in short capillaries using contactless conductivity detection and a sequential injection analysis manifold for hydrodynamic sample loadingThe Analyst, 2006
- Conductivity detection for conventional and miniaturised capillary electrophoresis systemsElectrophoresis, 2004
- Miniaturized movable contactless conductivity detection cell for capillary electrophoresisElectrophoresis, 2003
- The principles of migration and dispersion in capillary zone electrophoresis in nonaqueous solventsElectrophoresis, 2003
- Dynamically coating the capillary with 1-alkyl-3-methylimidazolium-based ionic liquids for separation of basic proteins by capillary electrophoresisAnalytica Chimica Acta, 2003
- Effect of Ionic Liquids as Mobile Phase Additives on Retention of Catecholamines in Reversed-Phase High-Performance Liquid ChromatographyAnalytical Letters, 2003
- Recent advances in nonaqueous capillary electrophoresisElectrophoresis, 2002
- Ionic liquids as electrolytes for nonaqueous capillary electrophoresisElectrophoresis, 2002
- Non-aqueous capillary electrophoresis in acetonitrile using lonic-liquid buffer electrolytesChromatographia, 2001
- Contactless Conductivity Detection for Capillary ElectrophoresisAnalytical Chemistry, 1998