Abstract
Current measurement scaling error (CMSE) is a common problem in permanent magnet synchronous machine (PMSM) drive systems. It can be categorized into current measurement scaling difference error (CMSDE) and current measurement scaling average error (CMSAE). This research aims to analyze and eliminate the effects of the CMSE on rotating high-frequency voltage injection (HFVI)-based sensorless control. Firstly, a detailed analysis of the CMSE-induced position estimation error is presented, revealing the relationship between the position estimation error and the CMSE. It indicates that the CMSE introduces both a DC offset and a 2nd harmonic into the position estimation. Secondly, an effective sequential elimination strategy is proposed to address the CMSDE as its first step, and then the CMSAE as the second step. A moving average filter (MAF) is designed to extract the error signal, followed by a sliding mode controller (SMC) to eliminate the CMSDE and CMSAE. Finally, the theoretical analysis and the elimination methods of the CMSE have been validated by the experimental results.
Funding Information
  • National Natural Science Foundation of China (52207038)
  • Research and Demonstration of Key Technologies for Smart Water Supply and Green Operation in Lingang New Area

This publication has 23 references indexed in Scilit: