Continuously moving table MRI with golden angle radial sampling
- 2 December 2014
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 74 (6) , 1690-1697
Abstract
Purpose Continuously moving table (CMT) MRI is a high throughput technique that has multiple applications in whole‐body imaging. In this work, CMT MRI based on golden angle (GA, 111.246° azimuthal step) radial sampling is developed at 3 Tesla (T), with the goal of increased flexibility in image reconstruction using arbitrary profile groupings. Theory and Methods CMT MRI with GA and linear angle (LA) schemes were developed for whole‐body imaging at 3T with a table speed of 20 mm/s. Imaging was performed in phantoms and a human volunteer with extended z fields of view of up to 1.8 meters. Four separate LA and a single GA scan were performed to enable slice reconstructions at four different thicknesses. Results GA CMT MRI produced high image quality in phantoms and humans and allowed complete flexibility in reconstruction of slices with arbitrary slice thickness and position from a single data set. LA CMT MRI was constrained by predetermined parameters, required multiple scans and suffered from stair step artifacts that were not present in GA images. Conclusion GA sampling provides a robust flexible approach to CMT whole‐body MRI with the ability to reconstruct slices at arbitrary positions and thicknesses from a single scan. Magn Reson Med 74:1690–1697, 2015.Keywords
Funding Information
- NCATS/NIH (UL1 RR024975)
- NIDDK/NIH (R21DK096282)
- NCI/NIH (R25CA092043)
This publication has 43 references indexed in Scilit:
- An Optimal Radial Profile Order Based on the Golden Ratio for Time-Resolved MRIIEEE Transactions on Medical Imaging, 2006
- Emerging techniques: Whole‐body screening and staging with MRIJournal of Magnetic Resonance Imaging, 2006
- Continuously moving table 3D MRI with lateral frequency‐encoding directionMagnetic Resonance in Medicine, 2006
- Interactive continuously moving table (iCMT) large field‐of‐view real‐time MRIMagnetic Resonance in Medicine, 2006
- Multicontrast sequences with continuous table motion: A novel acquisition technique for extended field of view imagingMagnetic Resonance in Medicine, 2006
- Numerical equilibration of signal intensity and spatial resolution in time‐resolved continuously moving table imagingMagnetic Resonance in Medicine, 2006
- 2D axial moving table acquisitions with dynamic slice adaptationMagnetic Resonance in Medicine, 2006
- High-Resolution Whole-Body Magnetic Resonance Image Tumor Staging With the Use of Parallel Imaging Versus Dual-Modality Positron Emission Tomography–Computed TomographyInvestigative Radiology, 2005
- Continuously moving table MRI with SENSE: Application in peripheral contrast enhanced MR angiographyMagnetic Resonance in Medicine, 2005
- Recovery of phase inconsistencies in continuously moving table extended field of view magnetic resonance imaging acquisitionsMagnetic Resonance in Medicine, 2005