Abstract
The mechanism of overvoltage formation in the breaking process of a dry-type air-core shunt reactor (DTACSR) is studied in this paper. In addition, the effect of the overvoltage on the interturn insulation characteristics of the DTACSR is also discussed. Based on the actual working condition of a 66 kV DTACSR used in the Chinese power system, a three-phase simulation model and an equivalent circuit are proposed. The maximum chopping overvoltage and reignition overvoltage are obtained through the combination of theoretical analysis, a simulation and data fitting. An overvoltage accumulation test of the interturn insulation specimens is carried out with our established test platform, and the characteristic parameters of the interturn insulation specimens of the DTACSR in different stages of aging are measured. The results show that the combined method is very effective in evaluating the switching overvoltage of the DTACSR. Compared with the traditional single-phase circuit model, the proposed three-phase circuit model obtains a more accurate overvoltage equation. During the breaking process of a DTACSR, a chopping overvoltage with an amplitude greater than 5 p.u. and a reignition overvoltage with an amplitude greater than 8 p.u. may form. The cumulative effect of the overvoltage causes aging of the interturn insulation, and the degree of aging becomes more serious as the amplitude of the overvoltage increases.Keywords
Funding Information
- National Basic Research Program of China (2017YFB0902705)
- State Grid Corporation of China
This publication has 13 references indexed in Scilit:
- Aging characteristics of epoxy resin discharged by very fast transient overvoltage in SF6IEEE Transactions on Dielectrics and Electrical Insulation, 2017
- A Novel Hybrid Differential Algorithm for Turn to Turn Fault Detection in Shunt ReactorsIEEE Transactions on Power Delivery, 2017
- Damaging Open-Phase Overvoltage Disturbance on a Shunt-Compensated 500-kV Line Initiated by Unintended TripIEEE Transactions on Power Delivery, 2014
- Phenomena and Mechanism Analysis on Overvoltages Caused by 40.5-kV Vacuum Circuit Breakers Switching Off Shunt ReactorsIEEE Transactions on Power Delivery, 2011
- Modeling ${\rm SF}_{6}$ Circuit Breaker for Characterizing Shunt Reactor Switching TransientsIEEE Transactions on Power Delivery, 2007
- Electrical aging and life models: the role of space chargeIEEE Transactions on Dielectrics and Electrical Insulation, 2005
- An investigation of transient overvoltage generation when switching high voltage shunt reactors by SF/sub 6/ circuit breakerIEEE Transactions on Power Delivery, 1998
- A new IEEE Application Guide for Shunt Reactor SwitchingIEEE Transactions on Power Delivery, 1996
- Investigations of multiple reignition phenomena and protection scheme of shunt reactor current interruption in GIS substationsIEEE Transactions on Power Delivery, 1993
- A complete model of a single layer air-cored reactor for impulse voltage distributionIEEE Transactions on Power Delivery, 1988