Microrough Cobalt–Chromium Alloy Surfaces for Paclitaxel Delivery: Preparation, Characterization, andIn VitroDrug Release Studies
- 26 July 2012
- journal article
- research article
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 28 (31) , 11511-11526
Abstract
Cobalt–chromium (Co–Cr) alloys have extensive biomedical applications including drug-eluting stents (DES). This study investigates the use of eight different microrough Co–Cr alloy surfaces for delivering paclitaxel (PAT) for potential use in DES. The eight different surfaces include four bare microrough and four self-assembled monolayer (SAM) coated microrough surfaces. The bare microrough surfaces were prepared by grit blasting Co–Cr with glass beads (50 and 100 μm in size) and Al2O3 (50 and 110 μm). The SAM coated surfaces were prepared by depositing a −COOH terminated phosphonic acid monolayer on the different microrough surfaces. PAT was then deposited on all the bare and SAM coated microrough surfaces. The surfaces were characterized using scanning electron microscopy (SEM), 3D optical profilometry, and Fourier transform infrared spectroscopy (FTIR). SEM showed the different morphologies of microrough surfaces without and with PAT coating. An optical profiler showed the 3D topography of the different surfaces and the changes in surface roughness and surface area after SAM and PAT deposition. FTIR showed ordered SAMs were formed on glass bead grit blasted surfaces, while the molecules were disordered on Al2O3 grit blasted surfaces. Also, FTIR showed the successful deposition of PAT on these surfaces. The PAT release was investigated for up to two weeks using high performance liquid chromatography. Al2O3 grit blasted bare microrough surfaces showed sustained release profiles, while the glass bead grit blasted surfaces showed burst release profiles. All SAM coated surfaces showed biphasic drug release profiles, which is an initial burst release followed by a slow and sustained release. SAM coated Al2O3 grit blasted surfaces prolonged the sustained release of PAT in a significant amount during the second week of drug elution studies, while this behavior was not observed for any other surfaces used in this study. Thus, this study demonstrates the use of different microrough Co–Cr alloy surfaces for delivering PAT for potential applications in DES and other medical devices.Keywords
This publication has 68 references indexed in Scilit:
- Paclitaxel coating of the luminal surface of hemodialysis grafts with effective suppression of neointimal hyperplasiaJournal of Vascular Surgery, 2012
- Nanoparticle Size and Surface Charge Determine Effects of PAMAM Dendrimers on Human Platelets in VitroMolecular Pharmaceutics, 2011
- Paclitaxel-Eluting Biodegradable Synthetic Vascular ProsthesesCirculation, 2009
- 1-Year Results of the Hydroxyapatite Polymer-Free Sirolimus-Eluting Stent for the Treatment of Single De Novo Coronary LesionsJACC: Cardiovascular Interventions, 2009
- Coating irregularities of durable polymer-based drug-eluting stents as assessed by scanning electron microscopyEuroIntervention, 2009
- Characterization and Biological Evaluation of Paclitaxel-Loaded Poly(l-lactic acid) Microparticles Prepared by Supercritical CO2Langmuir, 2008
- Evaluation of a Novel Slow-Release Paclitaxel-Eluting Stent With a Bioabsorbable Polymeric Surface CoatingJACC: Cardiovascular Interventions, 2008
- Physical and chemical stability of paclitaxel infusions in different container typesJournal of Oncology Pharmacy Practice, 2006
- The Taxus™ drug-eluting stent: A new paradigm in controlled drug deliveryAdvanced Drug Delivery Reviews, 2006
- Influence of Surface Topography on Alkanethiol SAMs Assembled from Solution and by Microcontact PrintingLangmuir, 2001