Gopinath Mani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gopinath Mani has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Sujan Lamichhane
Biomedical Engineering, The University of South Dakota, 4800 North Career Avenue, Sioux Falls, SD 57107, USA
5 shared publicationsPatrick Kelly
Sanford Health, 1305 West 18th Street, Sioux Falls, SD 57105, USA
3 shared publicationsTyler Remund
Sanford Research, 2301 East 60th Street North, Sioux Falls, SD 57104, USA
3 shared publicationsAnnemarie Gallo
The University of South Dakota
2 shared publicationsJordan A. Anderson
Biomedical Engineering, The University of South Dakota, 4800 North Career Avenue, Sioux Falls, SD 57107, USA
2 shared publicationsSusan Lancaster
Biomedical Engineering Program, The University of South Dakota, 4800 North Career Avenue, Sioux Falls, South Dakota 57107, United States
2 shared publications
Latest Publications
- 12 June 2016
- Published by Springer Nature
- p. 159-166
Chapter 1b Metallic Biomaterials: Cobalt-Chromium Alloys
- 12 June 2016
- Published by Springer Nature
- p. 159-166
Chapter 1b Metallic Biomaterials: Cobalt-Chromium Alloys
- Open Access
- 1 January 2016
- Published by Elsevier in Acta Biomaterialia
- Vol. 29, 333-351
Preparation, characterization, in vitro drug release, and cellular interactions of tailored paclitaxel releasing polyethylene oxide films for drug-coated balloons
- 1 January 2016
- Published by Elsevier in Acta Biomaterialia
- Vol. 29, 333-351
Open AccessPreparation, characterization, in vitro drug release, and cellular interactions of tailored paclitaxel releasing polyethylene oxide films for drug-coated balloons
- 29 October 2015
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 105 (2) , 376-390
In vitro and in vivo evaluation of effect of excipients in local delivery of paclitaxel using microporous infusion balloon catheters
Drug‐infusion balloons are one of the currently used local drug delivery devices for preventing restenosis after endovascular treatments. An antiproliferative drug (paclitaxel, PAT) is infused through the balloon using a cremophor‐based formulation to control restenosis. However, the major limitations of this approach are poor in vivo drug uptake and a limit in the amount of PAT delivered because of cremophor toxicity. In this study, we have investigated the use of different excipients for effectively infusing PAT out of the balloon for improved drug uptake in the tissue. The excipients include nanoparticle albumin‐bound PAT (nab‐PAT, a nanobiomaterial used in cancer therapy), urea (a hydrophilic agent used for faster drug transfer), iodixanol (a contrast agent used for coronary angiography), and cremophor‐PAT (the most commonly used PAT formulation). An in vitro drug release, smooth muscle cell (SMC) response, endothelial cell (EC) response, and in vivo drug uptake were investigated for all the different excipients of PAT infused through the balloon. The nab‐PAT was as effective as cremophor in infusing out of the balloon and inhibiting SMC growth. Also, nab‐PAT showed a significantly greater amount of in vivo PAT uptake than that of cremophor‐PAT. Urea and iodixanol were not effective in delivering a clinically relevant dose of PAT due to the poor solubility of PAT in these excipients. Urea eradicated all the SMCs and ECs, suggesting a toxic effect, which impedes its use in balloon‐based therapy. Thus, this study demonstrated that nab‐PAT is an effective formulation to locally deliver PAT through infusion balloons. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 376–390, 2017.
- 29 October 2015
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 105 (2) , 376-390
In vitro and in vivo evaluation of effect of excipients in local delivery of paclitaxel using microporous infusion balloon catheters
Drug‐infusion balloons are one of the currently used local drug delivery devices for preventing restenosis after endovascular treatments. An antiproliferative drug (paclitaxel, PAT) is infused through the balloon using a cremophor‐based formulation to control restenosis. However, the major limitations of this approach are poor in vivo drug uptake and a limit in the amount of PAT delivered because of cremophor toxicity. In this study, we have investigated the use of different excipients for effectively infusing PAT out of the balloon for improved drug uptake in the tissue. The excipients include nanoparticle albumin‐bound PAT (nab‐PAT, a nanobiomaterial used in cancer therapy), urea (a hydrophilic agent used for faster drug transfer), iodixanol (a contrast agent used for coronary angiography), and cremophor‐PAT (the most commonly used PAT formulation). An in vitro drug release, smooth muscle cell (SMC) response, endothelial cell (EC) response, and in vivo drug uptake were investigated for all the different excipients of PAT infused through the balloon. The nab‐PAT was as effective as cremophor in infusing out of the balloon and inhibiting SMC growth. Also, nab‐PAT showed a significantly greater amount of in vivo PAT uptake than that of cremophor‐PAT. Urea and iodixanol were not effective in delivering a clinically relevant dose of PAT due to the poor solubility of PAT in these excipients. Urea eradicated all the SMCs and ECs, suggesting a toxic effect, which impedes its use in balloon‐based therapy. Thus, this study demonstrated that nab‐PAT is an effective formulation to locally deliver PAT through infusion balloons. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 376–390, 2017.
- Open Access
- 31 July 2015
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 104 (7) , 1416-1430
Dextran sulfate as a drug delivery platform for drug‐coated balloons: Preparation, characterization, in vitro drug elution, and smooth muscle cell response
Drug‐coated balloons (DCBs) have now emerged as a promising approach to treat peripheral artery disease. However, a significant amount of drug from the balloon surface is lost during balloon tracking and results in delivering only a subtherapeutic dose of drug at the diseased site. Hence, in this study, the use of dextran sulfate (DS) polymer was investigated as a platform to control the drug release from balloons. An antiproliferative drug, paclitaxel (PAT), was incorporated into DS films (PAT‐DS). The characterizations using SEM, FT‐IR, and DSC showed that the films prepared were smooth and homogenous with PAT molecularly dispersed in the bulk of DS matrix in amorphous form. An investigation on the interaction of smooth muscle cells (SMCs) with control‐DS and PAT‐DS films showed that both films inhibited SMC growth, with a superior inhibitory effect observed for PAT‐DS films. PAT‐DS coatings were then produced on balloon catheters. The integrity of coatings was well‐maintained when the balloons were either deflated or inflated. In this study, up to 2.2 µg/mm2 of PAT was loaded on the balloons using the DS platform. Drug elution studies showed that only 10 to 20% of the total PAT loaded was released from the PAT‐DS coated balloons during the typical time period of balloon tracking (1 min) and then ∼80% of the total PAT loaded was released during the typical time period of balloon inflation and treatment (from 1 min to 4 min). Thus, this study demonstrated the use of DS as a platform to control drug delivery from balloons. © 2015 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1416–1430, 2016.
- 31 July 2015
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 104 (7) , 1416-1430
Open AccessDextran sulfate as a drug delivery platform for drug‐coated balloons: Preparation, characterization, in vitro drug elution, and smooth muscle cell response
Drug‐coated balloons (DCBs) have now emerged as a promising approach to treat peripheral artery disease. However, a significant amount of drug from the balloon surface is lost during balloon tracking and results in delivering only a subtherapeutic dose of drug at the diseased site. Hence, in this study, the use of dextran sulfate (DS) polymer was investigated as a platform to control the drug release from balloons. An antiproliferative drug, paclitaxel (PAT), was incorporated into DS films (PAT‐DS). The characterizations using SEM, FT‐IR, and DSC showed that the films prepared were smooth and homogenous with PAT molecularly dispersed in the bulk of DS matrix in amorphous form. An investigation on the interaction of smooth muscle cells (SMCs) with control‐DS and PAT‐DS films showed that both films inhibited SMC growth, with a superior inhibitory effect observed for PAT‐DS films. PAT‐DS coatings were then produced on balloon catheters. The integrity of coatings was well‐maintained when the balloons were either deflated or inflated. In this study, up to 2.2 µg/mm2 of PAT was loaded on the balloons using the DS platform. Drug elution studies showed that only 10 to 20% of the total PAT loaded was released from the PAT‐DS coated balloons during the typical time period of balloon tracking (1 min) and then ∼80% of the total PAT loaded was released during the typical time period of balloon inflation and treatment (from 1 min to 4 min). Thus, this study demonstrated the use of DS as a platform to control drug delivery from balloons. © 2015 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1416–1430, 2016.
- 5 April 2014
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 42 (6) , 1170-1184
A Polymer-Free Paclitaxel Eluting Coronary Stent: Effects of Solvents, Drug Concentrations and Coating Methods
Some polymer coatings used in drug-eluting stents (DES) cause adverse reactions. Hence, the use of self-assembled monolayers (SAMs) as a polymer-free platform to deliver an anti-proliferative drug (paclitaxel—PAT) from 2D metal substrates was previously demonstrated. In this study, we optimized the PAT coating on SAMs coated 3D coronary stents. For the optimization process, we investigated the effects of solvents (ethanol, DMSO, and their mixtures), drug concentrations (2, 3, 4, 8, and 12 mg/mL) in the coating solution, and coating methods (dip and spray) on PAT deposition. A solvent mixture of 75:25 v/v Et-OH:DMSO was determined to be the best for obtaining smooth and homogenous PAT coating. PAT coated stents prepared using 8 mg/mL and 3 mg/mL concentrations of PAT by dip and spray coating methods, respectively, were optimal in terms of carrying adequate drug doses (0.35 µg/mm2 for dipping and 0.76 µg/mm2 for spraying) as well as negligible defects observed in the coating. PAT was successfully released from SAMs coated stents in a biphasic manner with an initial burst followed by a sustained release for up to 10 weeks. Thus, this study sheds light on the effects of solvents, drug concentrations, and coating methods on preparing a polymer-free DES.
- 5 April 2014
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 42 (6) , 1170-1184
A Polymer-Free Paclitaxel Eluting Coronary Stent: Effects of Solvents, Drug Concentrations and Coating Methods
Some polymer coatings used in drug-eluting stents (DES) cause adverse reactions. Hence, the use of self-assembled monolayers (SAMs) as a polymer-free platform to deliver an anti-proliferative drug (paclitaxel—PAT) from 2D metal substrates was previously demonstrated. In this study, we optimized the PAT coating on SAMs coated 3D coronary stents. For the optimization process, we investigated the effects of solvents (ethanol, DMSO, and their mixtures), drug concentrations (2, 3, 4, 8, and 12 mg/mL) in the coating solution, and coating methods (dip and spray) on PAT deposition. A solvent mixture of 75:25 v/v Et-OH:DMSO was determined to be the best for obtaining smooth and homogenous PAT coating. PAT coated stents prepared using 8 mg/mL and 3 mg/mL concentrations of PAT by dip and spray coating methods, respectively, were optimal in terms of carrying adequate drug doses (0.35 µg/mm2 for dipping and 0.76 µg/mm2 for spraying) as well as negligible defects observed in the coating. PAT was successfully released from SAMs coated stents in a biphasic manner with an initial burst followed by a sustained release for up to 10 weeks. Thus, this study sheds light on the effects of solvents, drug concentrations, and coating methods on preparing a polymer-free DES.
- 6 November 2013
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 29 (46) , 14254-14264
Interaction of Endothelial and Smooth Muscle Cells with Cobalt–Chromium Alloy Surfaces Coated with Paclitaxel Deposited Self-Assembled Monolayers
The use of self-assembled monolayers (SAMs) as a polymer-free platform to deliver an antiproliferative drug, paclitaxel (PAT), from a stent material cobalt–chromium (CoCr) alloy has been previously demonstrated. In this study, the interaction of human aortic endothelial cells (ECs) and human aortic smooth muscle cells (SMCs) with CoCr alloy surfaces coated with SAMs- (SAMs-CoCr) and PAT-deposited SAMs (PAT-SAMs-CoCr) was investigated. A polished CoCr with no coatings was used as a control. The viability, proliferation, morphology, and phenotype of ECs and SMCs were investigated on these samples. SAMs-CoCr significantly enhanced the growth of ECs. Also, the ECs were well spreading with its typical morphological features and showed stronger PECAM-1 expression on SAMs-CoCr. This showed that the SAMs-CoCr surface is conducive to endothelialization. For PAT-SAMs-CoCr, although the adhesion of ECs was lower, the cells continued to proliferate with some degree of spreading and limited PECAM-1 expression. For SMCs, a significant decrease in the cell proliferation was observed on SAMs-CoCr when compared with that of Control-CoCr. PAT-SAMs-CoCr showed maximum inhibitory effect on the proliferation of SMCs. Also, the SMCs on PAT-SAMs-CoCr displayed a poorly spread discoid morphology with disarranged α-actin filaments. This showed that the PAT released from the SAMs platform successfully inhibited the growth of SMCs. Thus, this study showed the interaction of ECs and SMCs with SAMs-CoCr and PAT-SAMs-CoCr for potential uses in stents and other cardiovascular medical devices.
- 6 November 2013
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 29 (46) , 14254-14264
Interaction of Endothelial and Smooth Muscle Cells with Cobalt–Chromium Alloy Surfaces Coated with Paclitaxel Deposited Self-Assembled Monolayers
The use of self-assembled monolayers (SAMs) as a polymer-free platform to deliver an antiproliferative drug, paclitaxel (PAT), from a stent material cobalt–chromium (CoCr) alloy has been previously demonstrated. In this study, the interaction of human aortic endothelial cells (ECs) and human aortic smooth muscle cells (SMCs) with CoCr alloy surfaces coated with SAMs- (SAMs-CoCr) and PAT-deposited SAMs (PAT-SAMs-CoCr) was investigated. A polished CoCr with no coatings was used as a control. The viability, proliferation, morphology, and phenotype of ECs and SMCs were investigated on these samples. SAMs-CoCr significantly enhanced the growth of ECs. Also, the ECs were well spreading with its typical morphological features and showed stronger PECAM-1 expression on SAMs-CoCr. This showed that the SAMs-CoCr surface is conducive to endothelialization. For PAT-SAMs-CoCr, although the adhesion of ECs was lower, the cells continued to proliferate with some degree of spreading and limited PECAM-1 expression. For SMCs, a significant decrease in the cell proliferation was observed on SAMs-CoCr when compared with that of Control-CoCr. PAT-SAMs-CoCr showed maximum inhibitory effect on the proliferation of SMCs. Also, the SMCs on PAT-SAMs-CoCr displayed a poorly spread discoid morphology with disarranged α-actin filaments. This showed that the PAT released from the SAMs platform successfully inhibited the growth of SMCs. Thus, this study showed the interaction of ECs and SMCs with SAMs-CoCr and PAT-SAMs-CoCr for potential uses in stents and other cardiovascular medical devices.
- 1 September 2013
- Published by Future Science Ltd in Therapeutic Delivery
- Vol. 4 (9) , 1079-1082
Stent-based drug-delivery systems: current challenges and future trends
- 1 September 2013
- Published by Future Science Ltd in Therapeutic Delivery
- Vol. 4 (9) , 1079-1082
Stent-based drug-delivery systems: current challenges and future trends
- 26 July 2012
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 28 (31) , 11511-11526
Microrough Cobalt–Chromium Alloy Surfaces for Paclitaxel Delivery: Preparation, Characterization, andIn VitroDrug Release Studies
Cobalt–chromium (Co–Cr) alloys have extensive biomedical applications including drug-eluting stents (DES). This study investigates the use of eight different microrough Co–Cr alloy surfaces for delivering paclitaxel (PAT) for potential use in DES. The eight different surfaces include four bare microrough and four self-assembled monolayer (SAM) coated microrough surfaces. The bare microrough surfaces were prepared by grit blasting Co–Cr with glass beads (50 and 100 μm in size) and Al2O3 (50 and 110 μm). The SAM coated surfaces were prepared by depositing a −COOH terminated phosphonic acid monolayer on the different microrough surfaces. PAT was then deposited on all the bare and SAM coated microrough surfaces. The surfaces were characterized using scanning electron microscopy (SEM), 3D optical profilometry, and Fourier transform infrared spectroscopy (FTIR). SEM showed the different morphologies of microrough surfaces without and with PAT coating. An optical profiler showed the 3D topography of the different surfaces and the changes in surface roughness and surface area after SAM and PAT deposition. FTIR showed ordered SAMs were formed on glass bead grit blasted surfaces, while the molecules were disordered on Al2O3 grit blasted surfaces. Also, FTIR showed the successful deposition of PAT on these surfaces. The PAT release was investigated for up to two weeks using high performance liquid chromatography. Al2O3 grit blasted bare microrough surfaces showed sustained release profiles, while the glass bead grit blasted surfaces showed burst release profiles. All SAM coated surfaces showed biphasic drug release profiles, which is an initial burst release followed by a slow and sustained release. SAM coated Al2O3 grit blasted surfaces prolonged the sustained release of PAT in a significant amount during the second week of drug elution studies, while this behavior was not observed for any other surfaces used in this study. Thus, this study demonstrates the use of different microrough Co–Cr alloy surfaces for delivering PAT for potential applications in DES and other medical devices.
- 26 July 2012
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 28 (31) , 11511-11526
Microrough Cobalt–Chromium Alloy Surfaces for Paclitaxel Delivery: Preparation, Characterization, andIn VitroDrug Release Studies
Cobalt–chromium (Co–Cr) alloys have extensive biomedical applications including drug-eluting stents (DES). This study investigates the use of eight different microrough Co–Cr alloy surfaces for delivering paclitaxel (PAT) for potential use in DES. The eight different surfaces include four bare microrough and four self-assembled monolayer (SAM) coated microrough surfaces. The bare microrough surfaces were prepared by grit blasting Co–Cr with glass beads (50 and 100 μm in size) and Al2O3 (50 and 110 μm). The SAM coated surfaces were prepared by depositing a −COOH terminated phosphonic acid monolayer on the different microrough surfaces. PAT was then deposited on all the bare and SAM coated microrough surfaces. The surfaces were characterized using scanning electron microscopy (SEM), 3D optical profilometry, and Fourier transform infrared spectroscopy (FTIR). SEM showed the different morphologies of microrough surfaces without and with PAT coating. An optical profiler showed the 3D topography of the different surfaces and the changes in surface roughness and surface area after SAM and PAT deposition. FTIR showed ordered SAMs were formed on glass bead grit blasted surfaces, while the molecules were disordered on Al2O3 grit blasted surfaces. Also, FTIR showed the successful deposition of PAT on these surfaces. The PAT release was investigated for up to two weeks using high performance liquid chromatography. Al2O3 grit blasted bare microrough surfaces showed sustained release profiles, while the glass bead grit blasted surfaces showed burst release profiles. All SAM coated surfaces showed biphasic drug release profiles, which is an initial burst release followed by a slow and sustained release. SAM coated Al2O3 grit blasted surfaces prolonged the sustained release of PAT in a significant amount during the second week of drug elution studies, while this behavior was not observed for any other surfaces used in this study. Thus, this study demonstrates the use of different microrough Co–Cr alloy surfaces for delivering PAT for potential applications in DES and other medical devices.
- 1 April 2012
- Published by Elsevier in Applied Surface Science
- Vol. 258 (12) , 5061-5072
Effect of processing methods on drug release profiles of anti-restenotic self-assembled monolayers
- 1 April 2012
- Published by Elsevier in Applied Surface Science
- Vol. 258 (12) , 5061-5072
Effect of processing methods on drug release profiles of anti-restenotic self-assembled monolayers