Online Measurement of Wet Gas Mass Flowrate Based on Averaging Pitot Tube-Vortex Integrated Sensor
- 18 March 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Abstract
Wet gas flow is prevalent in various industries. Accurate online measurement of wet gas mass flowrate holds significant importance for energy conservation and economic efficiency. This study presents a novel online measurement scheme for wet gas mass flowrate based on an averaged Pitot tube-vortex integrated sensor. By employing this self-designed dual mode detection integrated sensor, two different types of signals, differential pressure (DP) and vortex frequency, were obtained in the same region as the wet gas flows through. Given the challenges posed by the poor vortex street signal in two-phase flow, we proposed a fusion algorithm rooted in empirical wavelet transform (EWT) and robust local mean decomposition (RLMD) to extract the characteristic frequency. The positive deviation factor F pd , characterized as the ratio of apparent mass flowrate to actual mass flowrate, was introduced to establish a correlation with the Lockhart-Martinelli parameter, X LM . This correlation rectifies the phenomenon where the predicted mass flowrate exceeds the true value. Additionally, a dimensionless measurement parameter R , defined as the ratio of the DP of the averaging Pitot tube to the DP of the pipe wall, was used to get the initial value of F pd , in order to start the iterative correction process. This method enhances the practicability of the F pd - X LM correlation and enables online non-separation measurement. Based on the experimental results, the measurement solution achieved relative error (RE) bands of ± 5% for 95% of the samples, with a mean absolute percentage error (MAPE) of 3.36%. The data show that the online wet gas measurement solution proposed in this study is viable and cost-effective.Keywords
Funding Information
- Post-graduate’s Innovation Fund Project of Hebei Province (CXZZBS2023026)
- Science and Technology Project of Hebei Education Department (QN2023077)
- National Natural Science Foundation of China (62173122)
- key Project of Natural Science Foundation of Hebei Province (F2021201031)
- Langfang Technology Plan Project (2021011062)
- Scientific Research Project of Langfang Normal University (XKF202201)
This publication has 36 references indexed in Scilit:
- Study on double differential pressure measurement method of gas-liquid two-phase flow in high gas content wellsFlow Measurement and Instrumentation, 2023
- Study of the factors influencing the over-reading characteristics of the precession VenturiFlow Measurement and Instrumentation, 2022
- A new correlation to determine the Lockhart-Martinelli parameter from vertical differential pressure for horizontal venturi tube over-reading correctionFlow Measurement and Instrumentation, 2022
- A modified model for wet gas flowrate measurement considering entrainment downstream of a cone meterFlow Measurement and Instrumentation, 2021
- Wet gas over-reading correction for ultrasonic flow metersExperiments in Fluids, 2019
- An expert recommendation algorithm based on Pearson correlation coefficient and FP-growthCluster Computing, 2018
- Comparison of the two-phase mass flow coefficient and the over-reading for wet gas flow metering with DP metersExperimental Thermal and Fluid Science, 2018
- Online measurement of gas and liquid flow rate in wet gas through one V-Cone throttle deviceExperimental Thermal and Fluid Science, 2016
- Experimental investigation of wet gas over reading in VenturiExperimental Thermal and Fluid Science, 2015
- Wet gas metering technique based on slotted orifice and swirlmeter in seriesFlow Measurement and Instrumentation, 2013