The Control of Tokamak Configuration Variable Plasmas
- 1 November 1997
- journal article
- research article
- Published by Taylor & Francis in Fusion Technology
- Vol. 32 (3) , 321-373
Abstract
The general control of tokamak plasmas has evolved considerably over the past few years with an increase in the plasma pulse length, an increase in the control of additional heating and fueling, and an increase in the degree to which the shape of the plasma can be varied. The Tokamak Configuration Variable (TCV) is specifically designed to explore the operational benefits of plasma shaping over a wide variety of plasma shapes. Consequently, considerable attention has been given to the control of the poloidal field coil currents that impose the desired shape. All aspects of the control of TCV plasmas, from the diagnostic measurements to the power supplies, via particular control algorithms and overall supervision are discussed.Keywords
This publication has 10 references indexed in Scilit:
- On locating the poloidal field coils for tokamak vertical position controlNuclear Fusion, 1996
- ELM control during double-null ohmic H modes in TCVNuclear Fusion, 1995
- Calculations of Axisymmetric Stability of Tokamak Plasmas with Active and Passive FeedbackJournal of Computational Physics, 1993
- Fast non-linear extraction of plasma equilibrium parameters using a neural network mappingNuclear Fusion, 1991
- Experimental study of the vertical stability of high decay index plasmas in the DIII-D tokamakNuclear Fusion, 1990
- Plasma shape and position control in highly elongated tokamaksNuclear Fusion, 1990
- Control of the vertical instability in tokamaksNuclear Fusion, 1990
- Tokamak equilibrium reconstruction using Faraday rotation measurementsNuclear Fusion, 1988
- Fast identification of plasma boundary and X-points in elongated tokamaksNuclear Fusion, 1988
- FBT - a free-boundary tokamak equilibrium code for highly elongated and shaped plasmasComputer Physics Communications, 1988