Septal–Inferior Vena Cava Angle and Accurate Septal Implantation of Leadless Pacemakers: Computed Tomography‐Based Study
- 6 August 2026
- journal article
- devices
- Published by Wiley in Pacing and Clinical Electrophysiology
Abstract
Background: The Micra leadless pacemaker (LPM) should ideally be implanted in the septal location to enhance safety. However, the probability of accurate septal implantation and its predictive factors have not been fully elucidated. Methods: Eighty‐three consecutive patients who underwent computed tomography (CT) following LPM implantation were included. The ventricular septum was targeted using a standard fluoroscopic‐guided transfemoral approach. The LPM implantation site was classified as septal or non‐septal based on CT findings. The septal–inferior vena cava (IVC) angle was evaluated as a patient‐specific anatomical parameter representing the relationship between IVC inflow and the ventricular septum. Results: Accurate septal implantation was achieved in 44 patients (53.0%). The septal–IVC angle was significantly larger in the septal group than in the non‐septal group (13.1 ± 11.6° vs. 2.7 ± 10.6°, p < 0.001). Multivariate logistic regression analysis indicated that the septal–IVC angle (odds ratio, 1.09; 95% confidence interval, 1.03–1.14; p = 0.002) was independently associated with the incidence of septal implantation. The optimal cutoff value for the septal–IVC angle was 6°, with a sensitivity of 77.3% and a specificity of 66.7% for predicting septal implantation. There were no cases of cardiac tamponade or pericardial effusion. No significant differences in long‐term outcomes, including all‐cause mortality, cardiac mortality, and heart failure hospitalization, were observed between the two groups. Conclusions: Accurate septal implantation was observed in 53.0% of patients who had undergone LPM implantation with the standard femoral approach. A larger septal–IVC angle was associated with accurate septal implantation.Keywords
This publication has 22 references indexed in Scilit:
- Computed Tomography‐Verified Pacing Location of Micra Leadless Pacemakers and Characteristics of Paced Electrocardiograms in Bradycardia PatientsClinical Cardiology, 2025
- Leadless pacemaker implantation via the internal jugular veinEP Europace, 2024
- Recurrent Pericardial Effusion Resulting From Right Ventricular Free Wall Injury Caused by Leadless Pacemaker TinesJACC: Case Reports, 2024
- Usefulness of delivery catheter on accurate right ventricular septal pacing: Mt FUJI trialEP Europace, 2023
- Influence of the right ventricular septum/free-wall boundary (hinge) on differentiation of the ventricular lead implantation siteJournal of Cardiology, 2022
- Development and validation of a risk score for predicting pericardial effusion in patients undergoing leadless pacemaker implantation: experience with the Micra transcatheter pacemakerEP Europace, 2022
- Prognostic impact of lead tip position confirmed via computed tomography in patients with right ventricular septal pacingHeart Rhythm, 2019
- Safety and feasibility of a midseptal implantation technique of a leadless pacemakerHeart Rhythm, 2019
- Long-term performance of a transcatheter pacing system: 12-Month results from the Micra Transcatheter Pacing StudyHeart Rhythm, 2017
- A Leadless Intracardiac Transcatheter Pacing SystemNew England Journal of Medicine, 2016