TOTakashi Okajima

Takashi Okajima

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Takashi Okajima has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Septal–Inferior Vena Cava Angle and Accurate Septal Implantation of Leadless Pacemakers: Computed Tomography‐Based Study

    by Takashi Okajima, Shinji Ishikawa, Yusuke Uemura, Yuta Ozaki, Shogo Yamaguchi, Takayuki Mitsuda, Kenji Takemoto, Yasuya Inden, Masato Watarai

    Background: The Micra leadless pacemaker (LPM) should ideally be implanted in the septal location to enhance safety. However, the probability of accurate septal implantation and its predictive factors have not been fully elucidated. Methods: Eighty‐three consecutive patients who underwent computed tomography (CT) following LPM implantation were included. The ventricular septum was targeted using a standard fluoroscopic‐guided transfemoral approach. The LPM implantation site was classified as septal or non‐septal based on CT findings. The septal–inferior vena cava (IVC) angle was evaluated as a patient‐specific anatomical parameter representing the relationship between IVC inflow and the ventricular septum. Results: Accurate septal implantation was achieved in 44 patients (53.0%). The septal–IVC angle was significantly larger in the septal group than in the non‐septal group (13.1 ± 11.6° vs. 2.7 ± 10.6°, p < 0.001). Multivariate logistic regression analysis indicated that the septal–IVC angle (odds ratio, 1.09; 95% confidence interval, 1.03–1.14; p = 0.002) was independently associated with the incidence of septal implantation. The optimal cutoff value for the septal–IVC angle was 6°, with a sensitivity of 77.3% and a specificity of 66.7% for predicting septal implantation. There were no cases of cardiac tamponade or pericardial effusion. No significant differences in long‐term outcomes, including all‐cause mortality, cardiac mortality, and heart failure hospitalization, were observed between the two groups. Conclusions: Accurate septal implantation was observed in 53.0% of patients who had undergone LPM implantation with the standard femoral approach. A larger septal–IVC angle was associated with accurate septal implantation.

  • Open Access

    Mapping Atrial Tachycardia Post‐Pulmonary Vein Isolation Using the PulseSelect Catheter and Ensite NavX

    by Takayuki Okamoto, Takashi Okajima, Shinji Ishikawa, Yusuke Uemura

    The nine 3-mm electrodes, 3.75-mm fixed interelectrode space, and soft and slightly tilted shape of the PulseSelect catheter enables creating high-quality 3D electroanatomical mapping. Combined with an Ensite NavX 3D mapping system, it may be a superior option for managing atrial tachycardia after pulmonary vein isolation with pulsed field ablation.


  • Efficacy of sodium-glucose cotransporter 2 inhibitors on preventing atrial arrhythmia recurrences after atrial fibrillation ablation in patients with heart failure

    by Takashi Okajima, Shinji Ishikawa, Yusuke Uemura, Yuta Ozaki, Shogo Yamaguchi, Takayuki Mitsuda, Kenji Takemoto, Yasuya Inden, Toyoaki Murohara, Masato Watarai


  • Synthesized V7 QRS Amplitude and Oversensing Episodes in Patients With Subcutaneous Implantable Cardioverter‐Defibrillators

    by Takashi Okajima, Shinji Ishikawa, Satoshi Yanagisawa, Takayuki Okamoto, Yusuke Uemura, Kenji Takemoto, Yasuya Inden, Toyoaki Murohara, Masato Watarai

    Background: Patients with subcutaneous implantable cardioverter‐defibrillators (S‐ICDs) experience an oversensing episode (OS) more frequently than those with transvenous ICDs. However, no established electrocardiography (ECG) parameters can accurately detect an OS. This study aimed to evaluate the incidence of an OS in real‐world clinical practice and the association of synthesized 18‐lead ECG (syn18‐ECG) parameters with an OS.Methods: We retrospectively included 21 consecutive patients who underwent S‐ICD implantation and collected syn18‐ECG parameters. We placed the generator in a deep posterior position and defined an OS as an inappropriate charging episode caused by cardiac or noncardiac signals. A SMART pass filter and two tachyarrhythmia zones were programed.Results: The most frequent underlying heart disease was Brugada/J wave syndrome (n = 7). During a median follow‐up period of 1188 days, an OS was observed in six patients (28.6%). The QRS amplitude in synthesized V7 lead (synV7) was significantly lower in the OS group than in the non‐OS group (0.59 ± 0.17 vs. 0.91 ± 0.35 mV, p = 0.019). The optimal cutoff value of synV7 QRS amplitude was 0.61 mV, with a sensitivity of 80.0% and a specificity of 83.7% for predicting an OS. Univariate logistic analysis showed that a synV7 QRS amplitude of p = 0.018).Conclusions: In patients with S‐ICDs, an OS was not a rare complication during long‐term follow‐up. A low synV7 QRS amplitude was associated with a high OS incidence.

  • Open Access

    Two‐step changes in paced QRS morphology suggest capturing at different levels of posterior fascicle fibers during left bundle branch area pacing: A case report

    by Takashi Okajima, Shinji Ishikawa, Yusuke Uemura, Kenji Takemoto, Masato Watarai

    Two‐step changes in paced QRS morphology during the left bundle branch area pacing threshold test. It suggests that capturing occurs at multiple sites of the left bundle branch‐Purkinje system.