Minifragment Screw Fixation of Oblique Metacarpal Fractures: A Biomechanical Analysis of Screw Types and Techniques
- 29 August 2008
- journal article
- research article
- Published by SAGE Publications in HAND
- Vol. 3 (4) , 311-315
Abstract
The lag screw technique has historically been a successful and accepted way to treat oblique metacarpal fractures. However, it does take additional time and involve multiple steps that can increase the risk of fracture propagation or comminution in the small hand bones of the hand. An alternate fixation technique uses bicortical interfragmentary screws. Other studies support the clinical effectiveness and ease of this technique. The purpose of this study is to biomechanically assess the strength of the bicortical interfragmentary screw versus that of the traditional lag screw. Using 48 cadaver metacarpals, oblique osteotomies were created and stabilized using one of four methods: 1.5 mm bicortical interfragmentary (IF) screw, 1.5 mm lag technique screw, 2.0 mm bicortical IF screw, or 2.0 mm lag technique screw. Biomechanical testing was performed to measure post cyclic displacement and load to failure. Data was analyzed using one-way analysis of variance (ANOVA). There was no significant difference among the fixation techniques with regard to both displacement and ultimate failure strength. There was a slight trend for a higher load to failure with the 2.0 mm IF screw and 2.0 mm lag screw compared to the 1.5 mm IF and 1.5 mm lag screws, but this was not significant. Our results support previously established clinical data that bicortical interfragmentary screw fixation is an effective treatment option for oblique metacarpal fractures. This technique has clinical importance because it is an option to appropriately stabilize the often small and difficult to control fracture fragments encountered in metacarpal fractures.Keywords
This publication has 15 references indexed in Scilit:
- Fixation of hand fractures with bicortical screwsThe Journal of Hand Surgery, 2005
- Low-severity metacarpal and phalangeal fractures treated with miniature plates and screwsArchives of orthopaedic and trauma surgery, 2004
- Complications of Plate Fixation in Metacarpal Fractures2002
- Management of fractures of the hand over the last 25 yearsThe Journal of Hand Surgery, 2000
- Complications and range of motion following plate fixation of metacarpal and phalangeal fracturesThe Journal of Hand Surgery, 1998
- Internal Fixation of Oblique Metacarpal FracturesClinical Orthopaedics and Related Research, 1996
- Mini and micro plating of phalangeal and metacarpal fractures: A biomechanical studyThe Journal of Hand Surgery, 1995
- Comparative fatigue strengths and stabilities of metacarpal internal fixation techniquesThe Journal of Hand Surgery, 1993
- Internal fixation of metacarpal and phalangeal fractures with AO minifragment screws and plates: a prospective studyInjury, 1993
- Fractures of the metacarpals: Treatment by A. O. screw and plate fixationJournal of Hand Surgery (European Volume), 1987