Matthew McDonnell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Matthew McDonnell has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Nikhil A. Thakur
Rhode Island Hospital, Providence, RI, US
3 shared publications - Alan H. Daniels
Department of Orthopaedics, Warren Alpert Medical School of Brown University, Providence, Rhode Island
2 shared publications - Mark Palumbo
Warren Alpert School of Medicine at Brown University, Providence, RI, US
2 shared publications Sarath Koruprolu
University of Toledo, Toledo, OH, US
2 shared publicationsAaron K Schachter
1 shared publicationAlan Daniels
Warren Alpert Medical School of BU/RI Hospital, Providence, RI, US
1 shared publication
Latest Publications
- 1 January 2016
- Published by Jaypee Brothers Medical Publishing
- p. 133
Anticoagulation, Venous Thromboembolism, and Prophylaxis in Spine Surgery
- 1 January 2016
- Published by Jaypee Brothers Medical Publishing
- p. 133
Anticoagulation, Venous Thromboembolism, and Prophylaxis in Spine Surgery
- 1 September 2015
- Published by Wolters Kluwer Health in Contemporary Spine Surgery
- Vol. 16 (9) , 1-7
Value and Cost Effectiveness of Common Spinal Surgical Procedures
- 1 September 2015
- Published by Wolters Kluwer Health in Contemporary Spine Surgery
- Vol. 16 (9) , 1-7
Value and Cost Effectiveness of Common Spinal Surgical Procedures
- 1 July 2014
- Published by Elsevier in The Spine Journal
- Vol. 14 (7) , 1235-6
Commentary on: "Sagittal alignment as a predictor of clinical adjacent segment pathology requiring surgery after anterior cervical arthrodesis".
- 1 July 2014
- Published by Elsevier in The Spine Journal
- Vol. 14 (7) , 1235-6
Commentary on: "Sagittal alignment as a predictor of clinical adjacent segment pathology requiring surgery after anterior cervical arthrodesis".
- 30 September 2013
- Published by Elsevier in The Spine Journal
- Vol. 13 (9) , S126-S127
Biomechanical Analysis of Pedicle Screw Fixation Constructs for Stabilization of Thoracolumbar Burst Fractures
- 30 September 2013
- Published by Elsevier in The Spine Journal
- Vol. 13 (9) , S126-S127
Biomechanical Analysis of Pedicle Screw Fixation Constructs for Stabilization of Thoracolumbar Burst Fractures
- 1 August 2013
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 95 (15) , e108-1
Critical Analysis of a Trauma Fellowship-Modeled, Six-Year Orthopaedic Surgery Training Program
Y was to determine the prevalence and types of injuries sustained at the workplace during the career of an orthopaedic surgeon as well as the impact of such injuries on practicing surgeons. Methods: A survey was developed to assess occupational injury among orthopaedic surgeons. Electronic surveys were distributed via e-mail to all orthopaedic surgeons in Tennessee. Data were analyzed to determine statistical associations of demographic and workplace factors with the rate of injury. Results: One hundred and forty (28%) of 495 surveys were returned, with representation from all orthopaedic subspecialties. Sixty-one (44%) of the respondents reported sustaining one or more injuries at the workplace during their career. A significant association was found between years performing surgery and prevalence of injury (p = 0.03), with surgeons working between twenty-one and thirty years reporting the most injuries. Twenty-five percent of respondents reported sustaining an injury to the hand; 19%, to the lower back; 10%, to the neck; 7%, to the shoulder; and 6%, to another area. Fourteen (10%) of all surgeons reported missing work as a result of a workplace injury, with five (4%) missing at least three weeks. Twenty-three surgeons (38% of injured respondents) reported that no institutional resources were available to support their recovery from the injury. Conclusions: Our study is the first of its kind, to our knowledge, to demonstrate that many orthopaedic surgeons sustain occupational injuries during their careers. The volume of work missed suggests that occupational injury has economic implications for the health-care system and providers. Given the number of injured respondents reporting no institutional support for occupational injuries, more attention should be focused on this issue....
- 1 August 2013
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 95 (15) , e108-1
Critical Analysis of a Trauma Fellowship-Modeled, Six-Year Orthopaedic Surgery Training Program
Y was to determine the prevalence and types of injuries sustained at the workplace during the career of an orthopaedic surgeon as well as the impact of such injuries on practicing surgeons. Methods: A survey was developed to assess occupational injury among orthopaedic surgeons. Electronic surveys were distributed via e-mail to all orthopaedic surgeons in Tennessee. Data were analyzed to determine statistical associations of demographic and workplace factors with the rate of injury. Results: One hundred and forty (28%) of 495 surveys were returned, with representation from all orthopaedic subspecialties. Sixty-one (44%) of the respondents reported sustaining one or more injuries at the workplace during their career. A significant association was found between years performing surgery and prevalence of injury (p = 0.03), with surgeons working between twenty-one and thirty years reporting the most injuries. Twenty-five percent of respondents reported sustaining an injury to the hand; 19%, to the lower back; 10%, to the neck; 7%, to the shoulder; and 6%, to another area. Fourteen (10%) of all surgeons reported missing work as a result of a workplace injury, with five (4%) missing at least three weeks. Twenty-three surgeons (38% of injured respondents) reported that no institutional resources were available to support their recovery from the injury. Conclusions: Our study is the first of its kind, to our knowledge, to demonstrate that many orthopaedic surgeons sustain occupational injuries during their careers. The volume of work missed suggests that occupational injury has economic implications for the health-care system and providers. Given the number of injured respondents reporting no institutional support for occupational injuries, more attention should be focused on this issue....
- 1 June 2013
- Vol. 42 (6) , E35-7
Wound hematoma after anterior cervical spine surgery: in vitro study of the pathophysiology of airway obstruction.
Airway obstruction by wound hematoma is a serious adverse event associated with anterior cervical spine surgery. Although intrinsic airway edema is the most plausible pathophysiologic mechanism of obstruction, we hypothesized that extrinsic compression of the trachea by a hematoma can result in airway occlusion at an angle to the sagittal plane. A silicone indenter and a servohydraulic test frame were used to apply pressure to the ventral neck of 7 human cadaveric specimens. Increasing pressure was applied in the anteroposterior (AP) and oblique planes until the trachea collapsed, as visualized with fluoroscopy. A paired t test was used to determine any statistically significant differences in maximum pressure or indenter displacement at tracheal occlusion between the 2 test modes. Mean (SD) pressure required to cause complete tracheal collapse was 227.9 (54.8) mm Hg in the AP test mode and 135.6 (73.4) mm Hg in the oblique test mode. The difference was statistically significant (P = .004). Indenter displacement was significantly higher in the AP mode than in the oblique mode (P = .031). The trachea can collapse from external force within a physiologic pressure range when pressure is applied in an oblique orientation. The mass effect of a wound hematoma appears to be a viable mechanism of airway occlusion.
- 1 June 2013
- Vol. 42 (6) , E35-7
Wound hematoma after anterior cervical spine surgery: in vitro study of the pathophysiology of airway obstruction.
Airway obstruction by wound hematoma is a serious adverse event associated with anterior cervical spine surgery. Although intrinsic airway edema is the most plausible pathophysiologic mechanism of obstruction, we hypothesized that extrinsic compression of the trachea by a hematoma can result in airway occlusion at an angle to the sagittal plane. A silicone indenter and a servohydraulic test frame were used to apply pressure to the ventral neck of 7 human cadaveric specimens. Increasing pressure was applied in the anteroposterior (AP) and oblique planes until the trachea collapsed, as visualized with fluoroscopy. A paired t test was used to determine any statistically significant differences in maximum pressure or indenter displacement at tracheal occlusion between the 2 test modes. Mean (SD) pressure required to cause complete tracheal collapse was 227.9 (54.8) mm Hg in the AP test mode and 135.6 (73.4) mm Hg in the oblique test mode. The difference was statistically significant (P = .004). Indenter displacement was significantly higher in the AP mode than in the oblique mode (P = .031). The trachea can collapse from external force within a physiologic pressure range when pressure is applied in an oblique orientation. The mass effect of a wound hematoma appears to be a viable mechanism of airway occlusion.
- 1 November 2012
- Published by Wolters Kluwer Health in Spine
- Vol. 37 (23) , E1438-E1443
Dynamic Biomechanical Examination of the Lumbar Spine With Implanted Total Disc Replacement Using a Pendulum Testing System
Study Design. Biomechanical cadaver investigation. Objective. To examine dynamic bending stiffness and energy absorption of the lumbar spine with and without implanted total disc replacement (TDR) under simulated physiological motion. Summary of Background Data. The pendulum testing system is capable of applying physiological compressive loads without constraining motion of functional spinal units (FSUs). The number of cycles to equilibrium observed under pendulum testing is a measure of the energy absorbed by the FSU. Methods. Five unembalmed, frozen human lumbar FSUs were tested on the pendulum system with axial compressive loads of 181 N, 282 N, 385 N, and 488 N before and after Synthes ProDisc-L TDR implantation. Testing in flexion, extension, and lateral bending began by rotating the pendulum to 5º resulting in unconstrained oscillatory motion. The number of rotations to equilibrium was recorded and bending stiffness (N·m/º) was calculated and compared for each testing mode. Results. In flexion/extension, the TDR constructs reached equilibrium with significantly (P < 0.05) fewer cycles than the intact FSU with compressive loads of 282 N, 385 N, and 488 N. Mean dynamic bending stiffness in flexion, extension, and lateral bending increased significantly with increasing load for both the intact FSU and TDR constructs (P < 0.001). In flexion, with increasing compressive loading from 181 N to 488 N, the bending stiffness of the intact FSUs increased from 4.0 N·m/º to 5.5 N·m/º, compared with 2.1 N·m/º to 3.6 N·m/º after TDR implantation. At each compressive load, the intact FSU was significantly stiffer than the TDR (P < 0.05). Conclusion. Lumbar FSUs with implanted TDR were found to be less stiff, but absorbed more energy during cyclic loading with an unconstrained pendulum system. Although the effects on clinical performance of motion-preserving devices are not fully known, these results provide further insight into the biomechanical behavior of these devices under approximated physiological loading conditions.
- 1 November 2012
- Published by Wolters Kluwer Health in Spine
- Vol. 37 (23) , E1438-E1443
Dynamic Biomechanical Examination of the Lumbar Spine With Implanted Total Disc Replacement Using a Pendulum Testing System
Study Design. Biomechanical cadaver investigation. Objective. To examine dynamic bending stiffness and energy absorption of the lumbar spine with and without implanted total disc replacement (TDR) under simulated physiological motion. Summary of Background Data. The pendulum testing system is capable of applying physiological compressive loads without constraining motion of functional spinal units (FSUs). The number of cycles to equilibrium observed under pendulum testing is a measure of the energy absorbed by the FSU. Methods. Five unembalmed, frozen human lumbar FSUs were tested on the pendulum system with axial compressive loads of 181 N, 282 N, 385 N, and 488 N before and after Synthes ProDisc-L TDR implantation. Testing in flexion, extension, and lateral bending began by rotating the pendulum to 5º resulting in unconstrained oscillatory motion. The number of rotations to equilibrium was recorded and bending stiffness (N·m/º) was calculated and compared for each testing mode. Results. In flexion/extension, the TDR constructs reached equilibrium with significantly (P < 0.05) fewer cycles than the intact FSU with compressive loads of 282 N, 385 N, and 488 N. Mean dynamic bending stiffness in flexion, extension, and lateral bending increased significantly with increasing load for both the intact FSU and TDR constructs (P < 0.001). In flexion, with increasing compressive loading from 181 N to 488 N, the bending stiffness of the intact FSUs increased from 4.0 N·m/º to 5.5 N·m/º, compared with 2.1 N·m/º to 3.6 N·m/º after TDR implantation. At each compressive load, the intact FSU was significantly stiffer than the TDR (P < 0.05). Conclusion. Lumbar FSUs with implanted TDR were found to be less stiff, but absorbed more energy during cyclic loading with an unconstrained pendulum system. Although the effects on clinical performance of motion-preserving devices are not fully known, these results provide further insight into the biomechanical behavior of these devices under approximated physiological loading conditions.
- 6 June 2012
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 94 (11) , 1030-1035
Injury Patterns Causing Isolated Foot Compartment Syndrome
Background: The true incidence and primary predictors of foot compartment syndrome remain controversial. Our aim was to better define the overall incidence of foot compartment syndrome in relation to the frequency and location of various foot injuries. We hypothesized that (1) the incidence would increase in proportion to the number of anatomic locations of injury, (2) the incidence would be higher in association with hindfoot and crush injuries compared with any other injury categories, and (3) not only would the incidence associated with calcaneal fractures be lower than the often quoted 10% but foot compartment syndrome would also be fairly uncommon after such fractures. Methods: The National Trauma Data Bank was used to identify patients who had undergone a fasciotomy for the treatment of isolated foot compartment syndrome. Strict inclusion and exclusion criteria were used to identify only patients with foot injuries who had undergone fasciotomy for foot compartment syndrome. Results: Three hundred and sixty-four patients with an isolated foot compartment syndrome were identified. The highest incidence of foot compartment syndrome was seen in association with a crush mechanism combined with a forefoot injury (18%, nineteen of 106), followed by an isolated crush injury (14%, twenty-three of 162). Only 1% (thirty-two) of 2481 patients with an isolated calcaneal fracture underwent fasciotomy. An increase in the number of anatomic locations of injury did not appear to correspond to an increased incidence of foot compartment syndrome. Conclusion: Our results demonstrate that injuries involving a crush mechanism, either in isolation or in combination with a forefoot injury, should raise suspicion about the possibility that a foot compartment syndrome will develop. Level of Evidence: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.
- 6 June 2012
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 94 (11) , 1030-1035
Injury Patterns Causing Isolated Foot Compartment Syndrome
Background: The true incidence and primary predictors of foot compartment syndrome remain controversial. Our aim was to better define the overall incidence of foot compartment syndrome in relation to the frequency and location of various foot injuries. We hypothesized that (1) the incidence would increase in proportion to the number of anatomic locations of injury, (2) the incidence would be higher in association with hindfoot and crush injuries compared with any other injury categories, and (3) not only would the incidence associated with calcaneal fractures be lower than the often quoted 10% but foot compartment syndrome would also be fairly uncommon after such fractures. Methods: The National Trauma Data Bank was used to identify patients who had undergone a fasciotomy for the treatment of isolated foot compartment syndrome. Strict inclusion and exclusion criteria were used to identify only patients with foot injuries who had undergone fasciotomy for foot compartment syndrome. Results: Three hundred and sixty-four patients with an isolated foot compartment syndrome were identified. The highest incidence of foot compartment syndrome was seen in association with a crush mechanism combined with a forefoot injury (18%, nineteen of 106), followed by an isolated crush injury (14%, twenty-three of 162). Only 1% (thirty-two) of 2481 patients with an isolated calcaneal fracture underwent fasciotomy. An increase in the number of anatomic locations of injury did not appear to correspond to an increased incidence of foot compartment syndrome. Conclusion: Our results demonstrate that injuries involving a crush mechanism, either in isolation or in combination with a forefoot injury, should raise suspicion about the possibility that a foot compartment syndrome will develop. Level of Evidence: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.
- 1 June 2011
- Vol. 94 (6) , 167, 171-2
New ACGME rules for supervision and duty hours: resident commentary.
- 1 June 2011
- Vol. 94 (6) , 167, 171-2
New ACGME rules for supervision and duty hours: resident commentary.
- 29 August 2008
- Published by SAGE Publications in HAND
- Vol. 3 (4) , 311-315
Minifragment Screw Fixation of Oblique Metacarpal Fractures: A Biomechanical Analysis of Screw Types and Techniques
The lag screw technique has historically been a successful and accepted way to treat oblique metacarpal fractures. However, it does take additional time and involve multiple steps that can increase the risk of fracture propagation or comminution in the small hand bones of the hand. An alternate fixation technique uses bicortical interfragmentary screws. Other studies support the clinical effectiveness and ease of this technique. The purpose of this study is to biomechanically assess the strength of the bicortical interfragmentary screw versus that of the traditional lag screw. Using 48 cadaver metacarpals, oblique osteotomies were created and stabilized using one of four methods: 1.5 mm bicortical interfragmentary (IF) screw, 1.5 mm lag technique screw, 2.0 mm bicortical IF screw, or 2.0 mm lag technique screw. Biomechanical testing was performed to measure post cyclic displacement and load to failure. Data was analyzed using one-way analysis of variance (ANOVA). There was no significant difference among the fixation techniques with regard to both displacement and ultimate failure strength. There was a slight trend for a higher load to failure with the 2.0 mm IF screw and 2.0 mm lag screw compared to the 1.5 mm IF and 1.5 mm lag screws, but this was not significant. Our results support previously established clinical data that bicortical interfragmentary screw fixation is an effective treatment option for oblique metacarpal fractures. This technique has clinical importance because it is an option to appropriately stabilize the often small and difficult to control fracture fragments encountered in metacarpal fractures.
- 29 August 2008
- Published by SAGE Publications in HAND
- Vol. 3 (4) , 311-315
Minifragment Screw Fixation of Oblique Metacarpal Fractures: A Biomechanical Analysis of Screw Types and Techniques
The lag screw technique has historically been a successful and accepted way to treat oblique metacarpal fractures. However, it does take additional time and involve multiple steps that can increase the risk of fracture propagation or comminution in the small hand bones of the hand. An alternate fixation technique uses bicortical interfragmentary screws. Other studies support the clinical effectiveness and ease of this technique. The purpose of this study is to biomechanically assess the strength of the bicortical interfragmentary screw versus that of the traditional lag screw. Using 48 cadaver metacarpals, oblique osteotomies were created and stabilized using one of four methods: 1.5 mm bicortical interfragmentary (IF) screw, 1.5 mm lag technique screw, 2.0 mm bicortical IF screw, or 2.0 mm lag technique screw. Biomechanical testing was performed to measure post cyclic displacement and load to failure. Data was analyzed using one-way analysis of variance (ANOVA). There was no significant difference among the fixation techniques with regard to both displacement and ultimate failure strength. There was a slight trend for a higher load to failure with the 2.0 mm IF screw and 2.0 mm lag screw compared to the 1.5 mm IF and 1.5 mm lag screws, but this was not significant. Our results support previously established clinical data that bicortical interfragmentary screw fixation is an effective treatment option for oblique metacarpal fractures. This technique has clinical importance because it is an option to appropriately stabilize the often small and difficult to control fracture fragments encountered in metacarpal fractures.