Evaluation of the Tempo® System: Improving the Microbiological Quality Monitoring of Human Milk
Authors:
Open Access
- 2 September 2020
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 8
Abstract
Background: Bacteriological testing of donor human milk is mostly done both before and after pasteurization to control contamination in the end-product and meet the microbiological standards. Although the plate count method represents a reliable and sensitive technique and is considered the gold standard for bacteriological testing, it is recognized for being time-consuming and requiring qualified personnel. Recently, faster testing technologies, mostly geared toward the food industry, have been developed. Among these, the bioMérieux TEMPO® system uses the most probable number method to assess microbiological content in a semi-automated fashion. Objective: The performances of the TEMPO® system in enumerating bacterial quality indicators in human milk were assessed and compared to the reference plate count method. Methods: Naturally and artificially contaminated human milk samples were used to compare the analytical performances of the TEMPO® system to the plate count technique. More specifically, bacteria belonging to the genera Bacillus, Enterobacteriaceae, Staphylococcus aureus, and total aerobic flora were screened using both methods. Bacteria isolated on agar plates containing selective media were identified by supplemental testing. Bacterial testing results and method parameters were compared using linear regression analyses and Bland-Altman approaches. Results: Naturally contaminated milk samples (n = 55) tested for total aerobic flora showed < 1 log (CFU/ml) discrepancy between the two methods in the output results for 98% of the samples. Comparative linear regression analyses demonstrate good correlations between the two methods (R2 > 0.9). At lower levels of bacterial contamination, the TEMPO® method precision (C.V. < 8%) and accuracy (> 83%) were comparable to plate counts. Conclusions: The analytical performances of the TEMPO® system for human milk bacteriological testing are equivalent to the reference plate count method. Results from the TEMPO® system are available within a 24-h turnaround time from sample inoculation without the need for further supplemental testing, suggesting that this semi-automated method could be implemented within milk bank operations as an in-process monitoring technology to optimize end-product quality and safety.Keywords
This publication has 38 references indexed in Scilit:
- Streptococcus agalactiae late‐onset neonatal infections: should breast milk be more systematically tested for bacterial contamination?Acta Paediatrica, 2012
- The human milk microbiome changes over lactation and is shaped by maternal weight and mode of deliveryThe American Journal of Clinical Nutrition, 2012
- Enumeration of micro-organisms in processed soy products with an automated most probable number method compared with standard plate methodLetters in Applied Microbiology, 2011
- Evaluation of three applications of a semi-automated most-probable-number method for the assessment of microbiological parameters in dairy productsAccreditation and Quality Assurance, 2011
- Guidelines for the establishment and operation of a donor human milk bankThe Journal of Maternal-Fetal & Neonatal Medicine, 2010
- Evaluation of the TEMPO® most probable number technique for the enumeration of Enterobacteriaceae in food and dairy productsJournal of Applied Microbiology, 2010
- Breastmilk Handling Routines for Preterm Infants in Sweden: A National Cross-Sectional StudyBreastfeeding Medicine, 2008
- Best practice guidelines for the operation of a donor human milk bank in an Australian NICUEarly Human Development, 2007
- Evaluation of the TEMPO® system: An automated method for food microbiological quality controlJournal of Biotechnology, 2007
- Neonatal Group B Streptococcal Infection Related to Breast MilkBreastfeeding Medicine, 2006