Danny Brouard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Danny Brouard has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Antoine Lewin
Affaires Médicales et Innovation, Héma-Québec, Québec, QC, Canada
2 shared publications- Denis Boudreau
Université Laval
2 shared publications - Jonathan Robidoux
Affiliation Héma-Québec, Affaires Médicales et Innovation, Quebec City, QC, Canada
2 shared publications Marie Joëlle de Grandmont
Département de chimie, Université de Montréal, Montréal, QC, Canada
2 shared publicationsMarie-Pierre Cayer
Département de chimie, Université de Montréal, Montréal, QC, Canada
2 shared publications- Marie-Pierre Cayer
Affiliation Héma-Québec, Affaires Médicales et Innovation, Quebec City, QC, Canada
2 shared publications
Latest Publications
- Open Access
- 22 October 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (10) , e0333558
Monitoring of Staphylococcus epidermidis biofilm formation on platelet storage bag surfaces
Platelet concentrates (PCs) are stored at 20–24˚C in a biologically favorable environment that may support bacterial growth. Staphylococcus epidermidis , a typical contaminant, can form biofilms in PCs, complicating detection and increasing the risk of transfusion-transmitted bacterial infections. The material composition and surface texture of PC storage bags may influence biofilm formation. The impact of different PC storage bag materials on S. epidermidis biofilm formation was evaluated using the ISO 4768:2023(E) crystal violet (CV) assay. Four surface conditions were tested: polyvinyl chloride (PVC) plasticized with n-butyryl-tri(n-hexyl)-citrate (BTHC) – both smooth and rough sides, PVC plasticized with tri-(2-ethylhexyl)-trimellitate (TEHTM) and ethylene-vinyl acetate (EVA). Coupons and bags made from each material were used in the experiments. Biofilm-positive S. epidermidis was cultured in tryptic soy broth (TSB), PCs and plasma and added on plastic coupons under static conditions or directly in the bags with agitation. Bacterial enumeration and CV assay were performed on days 2, 5, and 7. In TSB, EVA coupons significantly formed more biofilm than the smooth side of PVC-BTHC or TEHTM over seven days. In PCs, more biofilm formed on the rough side of PVC-BTHC coupons than the smooth side, with no other differences between plastics, suggesting similar biofilm amount across PC bag materials in the presence of platelets. No biofilm was detected on coupons in plasma. Under continuous agitation and reduced oxygen levels, only the rough side of PVC-BTHC showed significant biofilm formation in TSB in PC storage bags over seven days. These findings highlight the need for standardized biofilm testing and suggest that some plastics are more conducive to biofilm formation under static conditions. However, during blood bank storage (i.e., continuous agitation and reduced oxygen levels), biofilm formation is limited, regardless of the platelet bag material, thereby reducing the risk of undetected bacterial contamination.
- 22 October 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (10) , e0333558
Open AccessMonitoring of Staphylococcus epidermidis biofilm formation on platelet storage bag surfaces
Platelet concentrates (PCs) are stored at 20–24˚C in a biologically favorable environment that may support bacterial growth. Staphylococcus epidermidis , a typical contaminant, can form biofilms in PCs, complicating detection and increasing the risk of transfusion-transmitted bacterial infections. The material composition and surface texture of PC storage bags may influence biofilm formation. The impact of different PC storage bag materials on S. epidermidis biofilm formation was evaluated using the ISO 4768:2023(E) crystal violet (CV) assay. Four surface conditions were tested: polyvinyl chloride (PVC) plasticized with n-butyryl-tri(n-hexyl)-citrate (BTHC) – both smooth and rough sides, PVC plasticized with tri-(2-ethylhexyl)-trimellitate (TEHTM) and ethylene-vinyl acetate (EVA). Coupons and bags made from each material were used in the experiments. Biofilm-positive S. epidermidis was cultured in tryptic soy broth (TSB), PCs and plasma and added on plastic coupons under static conditions or directly in the bags with agitation. Bacterial enumeration and CV assay were performed on days 2, 5, and 7. In TSB, EVA coupons significantly formed more biofilm than the smooth side of PVC-BTHC or TEHTM over seven days. In PCs, more biofilm formed on the rough side of PVC-BTHC coupons than the smooth side, with no other differences between plastics, suggesting similar biofilm amount across PC bag materials in the presence of platelets. No biofilm was detected on coupons in plasma. Under continuous agitation and reduced oxygen levels, only the rough side of PVC-BTHC showed significant biofilm formation in TSB in PC storage bags over seven days. These findings highlight the need for standardized biofilm testing and suggest that some plastics are more conducive to biofilm formation under static conditions. However, during blood bank storage (i.e., continuous agitation and reduced oxygen levels), biofilm formation is limited, regardless of the platelet bag material, thereby reducing the risk of undetected bacterial contamination.
- Open Access
- 20 January 2023
- Published by Frontiers Media SA in Frontiers in Immunology
- Vol. 13, 1052424
Assessment of the longitudinal humoral response in non-hospitalized SARS-CoV-2-positive individuals at decentralized sites: Outcomes and concordance
Introduction: Early in the COVID-19 pandemic, reagent availability was not uniform, and infrastructure had to be urgently adapted to undertake COVID-19 surveillance.Methods: Before the validation of centralized testing, two enzyme-linked immunosorbent assays (ELISA) were established independently at two decentralized sites using different reagents and instrumentation. We compared the results of these assays to assess the longitudinal humoral response of SARS-CoV-2-positive (i.e., PCR-confirmed), non-hospitalized individuals with mild to moderate symptoms, who had contracted SARSCoV-2 prior to the appearance of variants of concern in Québec, Canada.Results: The two assays exhibited a high degree of concordance to identify seropositive individuals, thus validating the robustness of the methods. The results also confirmed that serum immunoglobulins persist ≥ 6 months post-infection among non-hospitalized adults and that the antibodies elicited by infection cross-reacted with the antigens from P.1 (Gamma) and B.1.617.2 (Delta) variants of concern.Discussion: Together, these results demonstrate that immune surveillance assays can be rapidly and reliably established when centralized testing is not available or not yet validated, allowing for robust immune surveillance.
- 20 January 2023
- Published by Frontiers Media SA in Frontiers in Immunology
- Vol. 13, 1052424
Open AccessAssessment of the longitudinal humoral response in non-hospitalized SARS-CoV-2-positive individuals at decentralized sites: Outcomes and concordance
Introduction: Early in the COVID-19 pandemic, reagent availability was not uniform, and infrastructure had to be urgently adapted to undertake COVID-19 surveillance.Methods: Before the validation of centralized testing, two enzyme-linked immunosorbent assays (ELISA) were established independently at two decentralized sites using different reagents and instrumentation. We compared the results of these assays to assess the longitudinal humoral response of SARS-CoV-2-positive (i.e., PCR-confirmed), non-hospitalized individuals with mild to moderate symptoms, who had contracted SARSCoV-2 prior to the appearance of variants of concern in Québec, Canada.Results: The two assays exhibited a high degree of concordance to identify seropositive individuals, thus validating the robustness of the methods. The results also confirmed that serum immunoglobulins persist ≥ 6 months post-infection among non-hospitalized adults and that the antibodies elicited by infection cross-reacted with the antigens from P.1 (Gamma) and B.1.617.2 (Delta) variants of concern.Discussion: Together, these results demonstrate that immune surveillance assays can be rapidly and reliably established when centralized testing is not available or not yet validated, allowing for robust immune surveillance.
- Open Access
- 14 January 2022
- Published by MDPI AG in Antibiotics
- Vol. 11 (1) , 107
Characterization of the Antibacterial Activity of an SiO2 Nanoparticular Coating to Prevent Bacterial Contamination in Blood Products
Technological innovations and quality control processes within blood supply organizations have significantly improved blood safety for both donors and recipients. Nevertheless, the risk of transfusion-transmitted infection remains non-negligible. Applying a nanoparticular, antibacterial coating at the surface of medical devices is a promising strategy to prevent the spread of infections. In this study, we characterized the antibacterial activity of an SiO2 nanoparticular coating (i.e., the “Medical Antibacterial and Antiadhesive Coating” [MAAC]) applied on relevant polymeric materials (PM) used in the biomedical field. Electron microscopy revealed a smoother surface for the MAAC-treated PM compared to the reference, suggesting antiadhesive properties. The antibacterial activity was tested against selected Gram-positive and Gram-negative bacteria in accordance with ISO 22196. Bacterial growth was significantly reduced for the MAAC-treated PVC, plasticized PVC, polyurethane and silicone (90–99.999%) in which antibacterial activity of ≥1 log reduction was reached for all bacterial strains tested. Cytotoxicity was evaluated following ISO 10993-5 guidelines and L929 cell viability was calculated at ≥90% in the presence of MAAC. This study demonstrates that the MAAC could prevent bacterial contamination as demonstrated by the ISO 22196 tests, while further work needs to be done to improve the coating processability and effectiveness of more complex matrices.
- 14 January 2022
- Published by MDPI AG in Antibiotics
- Vol. 11 (1) , 107
Open AccessCharacterization of the Antibacterial Activity of an SiO2 Nanoparticular Coating to Prevent Bacterial Contamination in Blood Products
Technological innovations and quality control processes within blood supply organizations have significantly improved blood safety for both donors and recipients. Nevertheless, the risk of transfusion-transmitted infection remains non-negligible. Applying a nanoparticular, antibacterial coating at the surface of medical devices is a promising strategy to prevent the spread of infections. In this study, we characterized the antibacterial activity of an SiO2 nanoparticular coating (i.e., the “Medical Antibacterial and Antiadhesive Coating” [MAAC]) applied on relevant polymeric materials (PM) used in the biomedical field. Electron microscopy revealed a smoother surface for the MAAC-treated PM compared to the reference, suggesting antiadhesive properties. The antibacterial activity was tested against selected Gram-positive and Gram-negative bacteria in accordance with ISO 22196. Bacterial growth was significantly reduced for the MAAC-treated PVC, plasticized PVC, polyurethane and silicone (90–99.999%) in which antibacterial activity of ≥1 log reduction was reached for all bacterial strains tested. Cytotoxicity was evaluated following ISO 10993-5 guidelines and L929 cell viability was calculated at ≥90% in the presence of MAAC. This study demonstrates that the MAAC could prevent bacterial contamination as demonstrated by the ISO 22196 tests, while further work needs to be done to improve the coating processability and effectiveness of more complex matrices.
- Open Access
- 6 October 2020
- Published by Wolters Kluwer Health in Journal of Trauma and Acute Care Surgery
- Vol. 90 (3) , 515-521
Drone versus ground delivery of simulated blood products to an urban trauma center: The Montreal Medi-Drone pilot study
BACKGROUND: Timely and safe distribution of quality blood products is a major challenge faced by blood banks around the world. Our primary objective was to determine if simulated blood product delivery to an urban trauma center would be more rapidly achieved by unmanned aerial vehicle (UAV) than by ground transportation. A secondary objective was to determine the feasibility of maintaining simulated blood product temperatures within a targeted range. METHODS: In this prospective pilot study, we used two distinct methods to compare UAV flight duration and ground transport times. Simulated blood products included packed red blood cells, platelet concentrate, and fresh frozen plasma. For each blood product type, three UAV flights were conducted. Temperature was monitored during transport using a probe coupled to a data logger inside each simulated blood product unit. RESULTS: All flights were conducted successfully without any adverse events or safety concerns reported. The heaviest payload transported was 6.4 kg, and the drone speed throughout all nine flights was 10 m/s. The mean UAV transportation time was significantly faster than ground delivery (17:06 ± 00:04 minutes vs. 28:54 ± 01:12 minutes, p < 0.0001). The mean ± SD initial temperature for packed red blood cells was 4.4°C ± 0.1°C with a maximum 5% mean temperature variability from departure to landing. For platelet concentrates, the mean ± SD initial temperature was 21.6°C ± 0.5°C, and the maximum variability observed was 0.3%. The mean ± SD initial fresh frozen plasma temperature was −19°C ± 2°C, and the greatest temperature variability was from −17°C ± 2°C to −16°C ± 2°C. CONCLUSIONS: Unmanned aerial vehicle transportation of simulated blood products was significantly faster than ground delivery. Simulated blood product temperatures remained within their respective acceptable ranges throughout transport. Further studies assessing UAV transport of real blood products in populated areas are warranted. LEVEL OF EVIDENCE: Therapeutic/care management, level IV.
- 6 October 2020
- Published by Wolters Kluwer Health in Journal of Trauma and Acute Care Surgery
- Vol. 90 (3) , 515-521
Open AccessDrone versus ground delivery of simulated blood products to an urban trauma center: The Montreal Medi-Drone pilot study
BACKGROUND: Timely and safe distribution of quality blood products is a major challenge faced by blood banks around the world. Our primary objective was to determine if simulated blood product delivery to an urban trauma center would be more rapidly achieved by unmanned aerial vehicle (UAV) than by ground transportation. A secondary objective was to determine the feasibility of maintaining simulated blood product temperatures within a targeted range. METHODS: In this prospective pilot study, we used two distinct methods to compare UAV flight duration and ground transport times. Simulated blood products included packed red blood cells, platelet concentrate, and fresh frozen plasma. For each blood product type, three UAV flights were conducted. Temperature was monitored during transport using a probe coupled to a data logger inside each simulated blood product unit. RESULTS: All flights were conducted successfully without any adverse events or safety concerns reported. The heaviest payload transported was 6.4 kg, and the drone speed throughout all nine flights was 10 m/s. The mean UAV transportation time was significantly faster than ground delivery (17:06 ± 00:04 minutes vs. 28:54 ± 01:12 minutes, p < 0.0001). The mean ± SD initial temperature for packed red blood cells was 4.4°C ± 0.1°C with a maximum 5% mean temperature variability from departure to landing. For platelet concentrates, the mean ± SD initial temperature was 21.6°C ± 0.5°C, and the maximum variability observed was 0.3%. The mean ± SD initial fresh frozen plasma temperature was −19°C ± 2°C, and the greatest temperature variability was from −17°C ± 2°C to −16°C ± 2°C. CONCLUSIONS: Unmanned aerial vehicle transportation of simulated blood products was significantly faster than ground delivery. Simulated blood product temperatures remained within their respective acceptable ranges throughout transport. Further studies assessing UAV transport of real blood products in populated areas are warranted. LEVEL OF EVIDENCE: Therapeutic/care management, level IV.
- Open Access
- 2 September 2020
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 8
Evaluation of the Tempo® System: Improving the Microbiological Quality Monitoring of Human Milk
Background: Bacteriological testing of donor human milk is mostly done both before and after pasteurization to control contamination in the end-product and meet the microbiological standards. Although the plate count method represents a reliable and sensitive technique and is considered the gold standard for bacteriological testing, it is recognized for being time-consuming and requiring qualified personnel. Recently, faster testing technologies, mostly geared toward the food industry, have been developed. Among these, the bioMérieux TEMPO® system uses the most probable number method to assess microbiological content in a semi-automated fashion. Objective: The performances of the TEMPO® system in enumerating bacterial quality indicators in human milk were assessed and compared to the reference plate count method. Methods: Naturally and artificially contaminated human milk samples were used to compare the analytical performances of the TEMPO® system to the plate count technique. More specifically, bacteria belonging to the genera Bacillus, Enterobacteriaceae, Staphylococcus aureus, and total aerobic flora were screened using both methods. Bacteria isolated on agar plates containing selective media were identified by supplemental testing. Bacterial testing results and method parameters were compared using linear regression analyses and Bland-Altman approaches. Results: Naturally contaminated milk samples (n = 55) tested for total aerobic flora showed < 1 log (CFU/ml) discrepancy between the two methods in the output results for 98% of the samples. Comparative linear regression analyses demonstrate good correlations between the two methods (R2 > 0.9). At lower levels of bacterial contamination, the TEMPO® method precision (C.V. < 8%) and accuracy (> 83%) were comparable to plate counts. Conclusions: The analytical performances of the TEMPO® system for human milk bacteriological testing are equivalent to the reference plate count method. Results from the TEMPO® system are available within a 24-h turnaround time from sample inoculation without the need for further supplemental testing, suggesting that this semi-automated method could be implemented within milk bank operations as an in-process monitoring technology to optimize end-product quality and safety.
- 2 September 2020
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 8
Open AccessEvaluation of the Tempo® System: Improving the Microbiological Quality Monitoring of Human Milk
Background: Bacteriological testing of donor human milk is mostly done both before and after pasteurization to control contamination in the end-product and meet the microbiological standards. Although the plate count method represents a reliable and sensitive technique and is considered the gold standard for bacteriological testing, it is recognized for being time-consuming and requiring qualified personnel. Recently, faster testing technologies, mostly geared toward the food industry, have been developed. Among these, the bioMérieux TEMPO® system uses the most probable number method to assess microbiological content in a semi-automated fashion. Objective: The performances of the TEMPO® system in enumerating bacterial quality indicators in human milk were assessed and compared to the reference plate count method. Methods: Naturally and artificially contaminated human milk samples were used to compare the analytical performances of the TEMPO® system to the plate count technique. More specifically, bacteria belonging to the genera Bacillus, Enterobacteriaceae, Staphylococcus aureus, and total aerobic flora were screened using both methods. Bacteria isolated on agar plates containing selective media were identified by supplemental testing. Bacterial testing results and method parameters were compared using linear regression analyses and Bland-Altman approaches. Results: Naturally contaminated milk samples (n = 55) tested for total aerobic flora showed < 1 log (CFU/ml) discrepancy between the two methods in the output results for 98% of the samples. Comparative linear regression analyses demonstrate good correlations between the two methods (R2 > 0.9). At lower levels of bacterial contamination, the TEMPO® method precision (C.V. < 8%) and accuracy (> 83%) were comparable to plate counts. Conclusions: The analytical performances of the TEMPO® system for human milk bacteriological testing are equivalent to the reference plate count method. Results from the TEMPO® system are available within a 24-h turnaround time from sample inoculation without the need for further supplemental testing, suggesting that this semi-automated method could be implemented within milk bank operations as an in-process monitoring technology to optimize end-product quality and safety.
- 1 April 2020
- Published by Wiley in Transfusion
- Vol. 60 (5) , 1032-1041
Development of a flow standard to enable highly reproducible measurements of deformability of stored red blood cells in a microfluidic device
BACKGROUND: Great deformability allows red blood cells (RBCs) to flow through narrow capillaries in tissues. A number of microfluidic devices with capillary‐like microchannels have been developed to monitor storage‐related impairment of RBC deformability during blood banking operations. This proof‐of‐concept study describes a new method to standardize and improve reproducibility of the RBC deformability measurements using one of these devices.STUDY DESIGN AND METHODS: The rate of RBC flow through the microfluidic capillary network of the microvascular analyzer (MVA) device made of polydimethylsiloxane was measured to assess RBC deformability. A suspension of microbeads in a solution of glycerol in phosphate‐buffered saline was developed to be used as an internal flow rate reference alongside RBC samples in the same device. RBC deformability and other in vitro quality markers were assessed weekly in six leukoreduced RBC concentrates (RCCs) dispersed in saline‐adenine‐glucose‐mannitol additive solution and stored over 42 days at 4°C.RESULTS: The use of flow reference reduced device‐to‐device measurement variability from 10% to 2%. Repeated‐measure analysis using the generalized estimating equation (GEE) method showed a significant monotonic decrease in relative RBC flow rate with storage from Week 0. By the end of storage, relative RBC flow rate decreased by 22 ± 6% on average.CONCLUSIONS: The suspension of microbeads was successfully used as a flow reference to increase reproducibility of RBC deformability measurements using the MVA. Deformability results suggest an early and late aging phase for stored RCCs, with significant decreases between successive weeks suggesting a highly sensitive measurement method.
- 1 April 2020
- Published by Wiley in Transfusion
- Vol. 60 (5) , 1032-1041
Development of a flow standard to enable highly reproducible measurements of deformability of stored red blood cells in a microfluidic device
BACKGROUND: Great deformability allows red blood cells (RBCs) to flow through narrow capillaries in tissues. A number of microfluidic devices with capillary‐like microchannels have been developed to monitor storage‐related impairment of RBC deformability during blood banking operations. This proof‐of‐concept study describes a new method to standardize and improve reproducibility of the RBC deformability measurements using one of these devices.STUDY DESIGN AND METHODS: The rate of RBC flow through the microfluidic capillary network of the microvascular analyzer (MVA) device made of polydimethylsiloxane was measured to assess RBC deformability. A suspension of microbeads in a solution of glycerol in phosphate‐buffered saline was developed to be used as an internal flow rate reference alongside RBC samples in the same device. RBC deformability and other in vitro quality markers were assessed weekly in six leukoreduced RBC concentrates (RCCs) dispersed in saline‐adenine‐glucose‐mannitol additive solution and stored over 42 days at 4°C.RESULTS: The use of flow reference reduced device‐to‐device measurement variability from 10% to 2%. Repeated‐measure analysis using the generalized estimating equation (GEE) method showed a significant monotonic decrease in relative RBC flow rate with storage from Week 0. By the end of storage, relative RBC flow rate decreased by 22 ± 6% on average.CONCLUSIONS: The suspension of microbeads was successfully used as a flow reference to increase reproducibility of RBC deformability measurements using the MVA. Deformability results suggest an early and late aging phase for stored RCCs, with significant decreases between successive weeks suggesting a highly sensitive measurement method.
- 13 April 2017
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 121 (16) , 8944-8951
Fluorescence and Scattering Dual-Mode Multiplexed Imaging with Gold–Silver Alloy Core Silica Shell Nanoparticles
- 13 April 2017
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 121 (16) , 8944-8951
Fluorescence and Scattering Dual-Mode Multiplexed Imaging with Gold–Silver Alloy Core Silica Shell Nanoparticles
- 3 December 2014
- Published by Wiley in Vox Sanguinis
- Vol. 108 (2) , 197-204
PCR‐free blood group genotyping using a nanobiosensor
The last two decades have seen major developments in genotyping assays to facilitate the procurement of red blood cell units to alloimmunized patients. To make genotyping faster, simpler and less costly, a nanotechnology approach based on metal/silica fluorescent nanoparticles and a polymer-based hybridization optical transducer was designed. The objectives of this study were (1) to verify whether this nanobiosensor has the ability to discriminate single nucleotide polymorphisms in non-amplified genomic DNA and (2) to establish whether the signal generated by the nanobiosensor is sufficiently intense to be detected by standard flow cytometry. Silver-core silica-shell fluorescent nanoparticles (Ag@SiO₂) were prepared, and amine-modified DNA probes were grafted to their surface. A cationic conjugated polymer was electrostatically bound to the surface probes to become optically active upon hybridization with a target. Two nanobiosensor formulations specific to DO*01 and DO*02 alleles were prepared. DNA was extracted from whole blood and mixed with the nanobiosensor for hybridization. The nanobiosensor fluorescence was measured by flow cytometry. Nine volunteers were typed for Dombrock blood group antigens DO*01 and DO*02. A statistically significant increase in the optical transduction signal was observed for sequence-specific samples. All nine genotypes were correctly identified when compared to standardized PCR assays. The nanobiosensor provides rapid and simple genotyping of blood group antigens from unamplified genomic DNA and can be measured using standard flow cytometers. This PCR-free approach could be applied to any known genetic polymorphism.
- 3 December 2014
- Published by Wiley in Vox Sanguinis
- Vol. 108 (2) , 197-204
PCR‐free blood group genotyping using a nanobiosensor
The last two decades have seen major developments in genotyping assays to facilitate the procurement of red blood cell units to alloimmunized patients. To make genotyping faster, simpler and less costly, a nanotechnology approach based on metal/silica fluorescent nanoparticles and a polymer-based hybridization optical transducer was designed. The objectives of this study were (1) to verify whether this nanobiosensor has the ability to discriminate single nucleotide polymorphisms in non-amplified genomic DNA and (2) to establish whether the signal generated by the nanobiosensor is sufficiently intense to be detected by standard flow cytometry. Silver-core silica-shell fluorescent nanoparticles (Ag@SiO₂) were prepared, and amine-modified DNA probes were grafted to their surface. A cationic conjugated polymer was electrostatically bound to the surface probes to become optically active upon hybridization with a target. Two nanobiosensor formulations specific to DO*01 and DO*02 alleles were prepared. DNA was extracted from whole blood and mixed with the nanobiosensor for hybridization. The nanobiosensor fluorescence was measured by flow cytometry. Nine volunteers were typed for Dombrock blood group antigens DO*01 and DO*02. A statistically significant increase in the optical transduction signal was observed for sequence-specific samples. All nine genotypes were correctly identified when compared to standardized PCR assays. The nanobiosensor provides rapid and simple genotyping of blood group antigens from unamplified genomic DNA and can be measured using standard flow cytometers. This PCR-free approach could be applied to any known genetic polymorphism.
- 31 December 2007
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 62 (12) , 1361-1369
Use of sol–gels as solid matrixes for laser-induced breakdown spectroscopy
- 31 December 2007
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 62 (12) , 1361-1369
Use of sol–gels as solid matrixes for laser-induced breakdown spectroscopy