Study Design The purpose of this study was to investigate the effects of implant selection and set-screw tightening technique on the loosening torques in long scoliosis constructs after long-term biaxial fatigue loading. Summary of Background Data Expanded use of pedicle screws in the correction of long scoliotic curves and the mechanical demands on segmental fixation systems requires surgeon awareness of revisiting set screws to ensure full screw/rod engagement and minimize the potential of set-screw loosening and/or rod slippage postoperatively. Methods Biomechanical tests were performed to evaluate the effect of set-screw tightening techniques and rod approximation on screw/rod interface strength. Results Rod reduction test shows the force required to approximate a rod to a pedicle screw is statistically lower with uniplanar or polyaxial screws, when compared with monoaxial screws. This ease of approximation in both polyaxial and uniplanar screws directly correlate to improvement in the axial slippage resistance. In the simulated spinal model construct, rod/screw securement can vary based on the number of tightening torques applied to the system. Conclusions Sequential revisiting of sets crews in long scoliosis constructs resulted in a statistically significant increase in loosening torque for monoaxial and polyaxial screw systems. Intraoperative securement assessment of set screws is recommended. The use of polyaxial and uniplanar screws at the distal ends in long constructs is recommended to increase the screw/rod interface strength.Keywords
This publication has 7 references indexed in Scilit:
- Biomechanics of Long Segment Fixation: Hook Patterns and Rod StrainJournal of Spinal Disorders, 2001
- The Effects of Hook Pattern and Kyphotic Angulation on Mechanical Strength and Apical Rod Strain in a Long-Segment Posterior Construct Using a Synthetic ModelSpine, 2001
- The Effect of Kyphosis on the Mechanical Strength of a Long-Segment Posterior Construct Using a Synthetic ModelSpine, 2000
- Does Spinal Instrumentation Influence the Healing Process of Posterolateral Spinal Fusion?Spine, 1999
- Radiographic Results of Arthrodesis with Cotrel-Dubousset Instrumentation for the Treatment of Adolescent Idiopathic Scoliosis. A Five to Ten-Year Follow-up Study*†Journal of Bone and Joint Surgery, 1998
- Static and Cyclical Biomechanical Analysis of Pedicle Screw Spinal ConstructsSpine, 1993
- 1989 Volvo Award in Basic Science: Device-Related Osteoporosis with Spinal InstrumentationSpine, 1989