Radiographic imaging systems can produce records of exposure and dose parameters for each patient. A variety of file formats are in use including plain text, bit map images showing pictures of written text and radiation dose structured reports as text or extended markup language files. Whilst some of this information is available with image data on the hospital picture archive and communication system, access is restricted to individual patient records, thereby making it difficult to locate multiple records for the same scan protocol. This study considers the exposure records and dose reports from four modalities. Exposure records for mammography and general radiography are utilized for repeat analysis. Dose reports for fluoroscopy and computed tomography (CT) are utilized to study the distribution of patient doses for each protocol. Results for dosimetric quantities measured by General Radiography, Fluoroscopy and CT equipment are summarised and presented in the Appendix. Projection imaging uses the dose (in air) area product and derived quantities including the dose to the reference point as a measure of the air kerma reaching the skin, ignoring movement of the beam for fluoroscopy. CT uses the dose indices CTDIvol and dose length product as a measure of the dose per axial slice, and to the scanned volume. Suitable conversion factors are identified and used to estimate the effective dose to an average size patient (for CT and fluoroscopy) and the entrance skin dose for fluoroscopy.Keywords
This publication has 11 references indexed in Scilit:
- AAPM Medical Physics Practice Guideline 1.a: CT Protocol Management and Review Practice GuidelineJournal of Applied Clinical Medical Physics, 2013
- Australian per caput dose from diagnostic imaging and nuclear medicineRadiation Protection Dosimetry, 2013
- Informatics in Radiology: RADIANCE: An Automated, Enterprise-wide Solution for Archiving and Reporting CT Radiation Dose EstimatesRadioGraphics, 2011
- Automated Extraction of Radiation Dose Information for CT ExaminationsJournal of the American College of Radiology, 2010
- Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length ProductRadiology, 2010
- Importance in optimization of multi‐slice computed tomography scan protocolsAustralasian Radiology, 2006
- Is Reject Analysis Necessary after Converting to Computed Radiography?Journal of Digital Imaging, 2002
- Recommendations for a mammography quality assurance programAustralasian Physics & Engineering Sciences in Medicine, 2001
- A comparison of image reject rates when using film, hard copy computed radiography and soft copy images on picture archiving and communication systems (PACS) workstations.British Journal of Radiology, 1999