    ACPSEM guideline regarding the adoption of the IAEA TRS-398 Code of Practice Revision 1

    by Joerg Lehmann, Jeffrey Barber, Andrew Alves, Simon Berke, Rhonda Brown, Peter Harty, Brendan Healy, Robin Hill, Stewart Midgley, Vaughan Moutrie, et al.

    The IAEA Technical Report Series 398 Code of Practice for the determination of absorbed dose in external beam radiotherapy was endorsed at the Engineers and Physical Scientists in Medicine (EPSM) conference in 2001 and has been widely adopted in Australia and New Zealand. This guideline provides recommendations from the Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) following the recent publication of TRS-398 Revision 1. It is jointly authored by the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA), the Reference Dosimetry Advisory Group (RDAG) and the ACPSEM Radiation Oncology Specialty Group (ROSG). In addition to recommendations, the guideline discusses the implications of TRS-398 Revision 1 for the dosimetry of megavoltage photons, electrons and protons. TRS-398 Revision 1 is recommended for adoption in accordance with the recommendations provided in this guideline, including for FFF beams. For specialised FFF machines such as CyberKnife ® and TomoTherapy ® , and for Gamma Knife ® , the ACPSEM recommends the use of IAEA TRS-483 Code of Practice. MR linacs are covered by the ACPSEM position paper: dosimetry for magnetic resonance imaging linear accelerators and in AAPM TG-351. For kilovoltage photons, the recommendation to use the AAPM TG-61 protocol for radiotherapy sources is retained and now specifically also includes cabinet irradiators used in radiobiology.

  • Open Access

    Synchrotron CT dosimetry for wiggler operation at reduced magnetic field and spatial modulation with bow tie filters

    by Stewart Midgley, Nanette Schleich, Andrew Stevenson, Alex Merchant

    The Australian Synchrotron Imaging and Medical Beamline (IMBL) uses a superconducting multipole wiggler (SCMPW) source, dual crystal Laue monochromator and 135 m propagation distance to enable imaging and computed tomography (CT) studies of large samples with mono-energetic radiation. This study aimed to quantify two methods for CT dose reduction: wiggler source operation at reduced magnetic field strength, and beam modulation with spatial filters placed upstream from the sample. Transmission measurements with copper were used to indirectly quantify the influence of third harmonic radiation. Operation at lower wiggler magnetic field strength reduces dose rates by an order of magnitude, and suppresses the influence of harmonic radiation, which is of significance near 30 keV. Beam shaping filters modulate the incident beam profile for near constant transmitted signal, and offer protection to radio-sensitive surface organs: the eye lens, thyroid and female breast. Their effect is to reduce the peripheral dose and the dose to the scanned volume by about 10% for biological samples of 35–50 mm diameter and by 20–30% for samples of up to 160 mm diameter. CT dosimetry results are presented as in-air measurements that are specific to the IMBL, and as ratios to in-air measurements that may be applied to other beamlines. As CT dose calculators for small animals are yet to be developed, results presented here and in a previous study may be used to estimate absorbed dose to organs near the surface and the isocentre.


  • CT dosimetry at the Australian Synchrotron for 25–100 keV photons and 35–160 mm-diameter biological specimens

    by Stewart Midgley, Nanette Schleich, Alex Merchant, Andrew Stevenson

    The dose length product (DLP) method for medical computed tomography (CT) dosimetry is applied on the Australian Synchrotron Imaging and Medical Beamline (IMBL). Beam quality is assessed from copper transmission measurements using image receptors, finding near 100% (20 keV), 3.3% (25 keV) and 0.5% (30–40 keV) relative contributions from third-harmonic radiation. The flat-panel-array medical image receptor is found to have a non-linear dose response curve. The amount of radiation delivered during an axial CT scan is measured as the dose in air alone, and inside cylindrical PMMA phantoms with diameters 35–160 mm for mono-energetic radiation 25–100 keV. The radiation output rate for the IMBL is comparable with that used for medical CT. Results are presented as the ratios of CT dose indices (CTDI) inside phantoms to in air with no phantom. Ratios are compared for the IMBL against medical CT where bow-tie filters shape the beam profile to reduce the absorbed dose to surface organs. CTDI ratios scale measurements in air to estimate the volumetric CTDI representing the average dose per unit length, and the dose length product representing the absorbed dose to the scanned volume. Medical CT dose calculators use the DLP, beam quality, axial collimation and helical pitch to estimate organ doses and the effective dose. The effective dose per unit DLP for medical CT is presented as a function of body region, beam energy and sample sizes from neonate to adult.


  • CT brain perfusion: A static phantom study of contrast‐to‐noise ratio and radiation dose

    by Stewart M Midgley, Damien L Stella, Bruce Cv Campbell, Francesca Langenberg, Paul F Einsiedel

    Introduction: Computed tomography perfusion (CTP) is increasingly employed in the diagnosis and management of ischaemic stroke but radiation dose can be significant and optimising contrast‐to‐noise ratio (CNR) is challenging. This study aimed to quantify and optimise the balance between CNR as a surrogate for image quality and radiation dose.Methods: A perspex head phantom with vials of dilute contrast agent was scanned using a Siemens Definition Flash 128‐slice scanner. The CTP protocol exposure parameters were adjusted over 70–120 kVp and 150–285 mAs. Measurements were obtained for the average dose per slice, Hounsfield Units (HU) for iodinated contrast agent, and the image noise for background regions of perspex. The CNR was measured as a function of the volumetric CT dose index (CTDIvol) and kVp.Results: A change from 120 to 80 kVp, achieved the same CNR with 60% reduction in dose. Alternatively, for the same dose, the change from 120 to 80 kVp improved CNR by +58%. A change from 80 to 70 kVp while operating at the same CNR, led to 13% reduction in dose. Alternatively, maintaining the same dose while changing from 80 to 70 kVp improved the CNR by +7%.Conclusion: Lower beam energies achieved the same CNR with less dose, or improved CNR at the same dose. A reduction from 80 kVp to 70 kVp may be clinically useful to optimise CTP acquisitions.


  • Dual-energy X-ray analysis using synchrotron computed tomography at 35 and 60 keV for the estimation of photon interaction coefficients describing attenuation and energy absorption

    by Stewart Midgley, Nanette Schleich

    A novel method for dual-energy X-ray analysis (DEXA) is tested using measurements of the X-ray linear attenuation coefficient μ. The key is a mathematical model that describes elemental cross sections using a polynomial in atomic number. The model is combined with the mixture rule to describe μ for materials, using the same polynomial coefficients. Materials are characterized by their electron densityNeand statistical momentsRkdescribing their distribution of elements, analogous to the concept of effective atomic number. In an experiment with materials of known density and composition, measurements of μ are written as a system of linear simultaneous equations, which is solved for the polynomial coefficients. DEXA itself involves computed tomography (CT) scans at two energies to provide a system of non-linear simultaneous equations that are solved forNeand the fourth statistical momentR4. Results are presented for phantoms containing dilute salt solutions and for a biological specimen. The experiment identifies 1% systematic errors in the CT measurements, arising from third-harmonic radiation, and 20–30% noise, which is reduced to 3–5% by pre-processing with the median filter and careful choice of reconstruction parameters. DEXA accuracy is quantified for the phantom as the mean absolute differences forNeandR4: 0.8% and 1.0% for soft tissue and 1.2% and 0.8% for bone-like samples, respectively. The DEXA results for the biological specimen are combined with model coefficients obtained from the tabulations to predict μ and the mass energy absorption coefficient at energies of 10 keV to 20 MeV.


  • A method for estimating radiation interaction coefficients for tissues from single energy CT

    by S M Midgley

    A parametric model for the x-ray linear attenuation coefficient is used to describe the compositional dependence of Hounsfield numbers measured by medical CT scanners. Measurements with materials of known density and composition, that span and evenly sample the compositional range of tissues, are written as linear simultaneous equations and solved for model coefficients. An algorithm is identified for this purpose. Results are expressed as atomic cross-sections in units of barn per electron divided by the attenuation coefficient for water. With the CT scanner characterised, a virtual CT scan can be simulated to predict HN for tissues based upon their known density and composition. Similar calculations using the tabulations and mixture rule deliver attenuation coefficients and mass energy absorption coefficients for mono-energetic radiation 10 keV to 20 MeV. Results are presented for measurements with a radiotherapy CT simulator, the RMI-467 phantom with tissue substitute materials, plus common polymer materials and silicon. Published measurements with earlier generations of the phantom and tissue substitutes using different CT scanners are also considered. Measured atomic cross-sections differ from expectations for mono-energetic radiation due to the use of a filtered spectrum and energy integrating detection system. The cross-sections for different CT scanners are similar, without large variations with kVp. Results are presented showing the relationship between predicted HN for tissues, electron density and photon interaction coefficients for healthy tissues and mono-energetic radiation. A strategy is suggested for accommodating strongly attenuating materials such as calculi and metallic implants.


  • Capture and analysis of radiation dose reports for radiology

    by S. M. Midgley

    Radiographic imaging systems can produce records of exposure and dose parameters for each patient. A variety of file formats are in use including plain text, bit map images showing pictures of written text and radiation dose structured reports as text or extended markup language files. Whilst some of this information is available with image data on the hospital picture archive and communication system, access is restricted to individual patient records, thereby making it difficult to locate multiple records for the same scan protocol. This study considers the exposure records and dose reports from four modalities. Exposure records for mammography and general radiography are utilized for repeat analysis. Dose reports for fluoroscopy and computed tomography (CT) are utilized to study the distribution of patient doses for each protocol. Results for dosimetric quantities measured by General Radiography, Fluoroscopy and CT equipment are summarised and presented in the Appendix. Projection imaging uses the dose (in air) area product and derived quantities including the dose to the reference point as a measure of the air kerma reaching the skin, ignoring movement of the beam for fluoroscopy. CT uses the dose indices CTDIvol and dose length product as a measure of the dose per axial slice, and to the scanned volume. Suitable conversion factors are identified and used to estimate the effective dose to an average size patient (for CT and fluoroscopy) and the entrance skin dose for fluoroscopy.


  • Reference dosimetry at the Australian Synchrotron's imaging and medical beamline using free‐air ionization chamber measurements and theoretical predictions of air kerma rate and half value layer

    by Jeffrey C. Crosbie, Peter A. W. Rogers, Andrew W. Stevenson, Christopher J. Hall, Jessica E. Lye, Terese Nordström, Stewart M. Midgley, Robert A. Lewis

    Purpose: Novel, preclinical radiotherapy modalities are being developed at synchrotrons around the world, most notably stereotactic synchrotron radiation therapy and microbeam radiotherapy at the European Synchrotron Radiation Facility in Grenoble, France. The imaging and medical beamline (IMBL) at the Australian Synchrotron has recently become available for preclinical radiotherapy and imaging research with clinical trials, a distinct possibility in the coming years. The aim of this present study was to accurately characterize the synchrotron‐generated x‐ray beam for the purposes of air kerma‐based absolute dosimetry.Methods: The authors used a theoretical model of the energy spectrum from the wiggler source and validated this model by comparing the transmission through copper absorbers (0.1–3.0 mm) against real measurements conducted at the beamline. The authors used a low energy free air ionization chamber (LEFAC) from the Australian Radiation Protection and Nuclear Safety Agency and a commercially available free air chamber (ADC‐105) for the measurements. The dimensions of these two chambers are different from one another requiring careful consideration of correction factors.Results: Measured and calculated half value layer (HVL) and air kerma rates differed by less than 3% for the LEFAC when the ion chamber readings were corrected for electron energy loss and ion recombination. The agreement between measured and predicted air kerma rates was less satisfactory for the ADC‐105 chamber, however. The LEFAC and ADC measurements produced a first half value layer of 0.405 ± 0.015 and 0.412 ± 0.016 mm Cu, respectively, compared to the theoretical prediction of 0.427 ± 0.012 mm Cu. The theoretical model based upon a spectrum calculator derived a mean beam energy of 61.4 keV with a first half value layer of approximately 30 mm in water.Conclusions: The authors showed in this study their ability to verify the predicted air kerma rate and x‐ray attenuation curve on the IMBL using a simple experimental method, namely, HVL measurements. The HVL measurements strongly supports the x‐ray beam spectrum, which in turn has a profound effect on x‐ray dosimetry.


  • Feasibility study for DEXA using synchrotron CT at 20–35 keV

    by S M Midgley

    A nonlinear model for the x-ray linear attenuation coefficient μ is employed for dual energy x-ray analysis (DEXA). Nonlinear simultaneous equations formed by μ and energy dependent model parameters are solved for the electron density N(e) and fourth compositional ratio R(4) which has the same 'units' as the atomic number. Computed tomography data was acquired at 20-35 keV using bending magnet synchrotron radiation, a double crystal monochromator, a rotation stage and an area detector. Test objects contained liquid samples as mixtures of ethanol, water and salt solutions with known density and composition. Various noise sources are identified and give μ uncertainties of 1-2%. A fan beam geometry allowed the detection of forward scattered radiation with measured μ being 6% lower than expectations for a narrow beam. Energy dependent model parameters were obtained by solving linear simultaneous equations formed by μ and material parameters based upon N(e) and R(4). DEXA accuracy was studied as a function of photon energy and sample composition. Propagation of errors analysis identifies the importance of the fractional compositional cross-products whose difference at the two beam energies should exceed 0.1, requiring 10 keV or more separation. For a reasonable approximation for the adjustable model parameters, the mean difference between the DEXA solution and true values (ΔN(e), ΔR(4)) are (1.0%, 0.5%) for soft tissue and (1.5%, 0.8%) for bone like samples.