Abstract
There is a general view that metal oxide surge arresters (MOSAs) are not in a position to offer an effective and consistent protection against very fast transient overvoltages (VFTOs). Quite predictably, it portrays MOSA in a poor light. The present sandwiched position of the arrester is mainly due to the combined effects of strong stray and block capacitances existing in an extra high voltage (EHV) network and the characteristic features of the incoming VFTOs. Contrary to this ‘popular view’, the theoretical performance assessment studies detailed here establish that a successful turnaround in the operation of MOSA under VFTOs is quite achievable. A detailed account of the electromagnetic transients programme (EMTP) and simulation studies performed is given; several oft‐repeated, critical questions are also addressed. Essential measures to shore up the operation of MOSAs under VFTOs have also been brought to the fore. Finally, this study is a culmination of the ‘persistent efforts, brings a happy ending to a long pending issue’ and paves way for an effective and consistent protection to gas insulated substation (GIS) and its connected equipment against all kinds of life‐threatening overvoltage surges that include VFTOs.Keywords
This publication has 15 references indexed in Scilit:
- Performance improvement of metal–oxide arrester for VFTsIET Science, Measurement & Technology, 2017
- Behavior Comparison of Metal Oxide Arrester Blocks When Excited by VFTO and LightningIEEE Transactions on Electromagnetic Compatibility, 2015
- Possible Measures to Enhance the Performance of Metal–Oxide Arresters in the EHV Network Under Very Fast TransientsIEEE Transactions on Power Delivery, 2015
- Very Fast Transient Overvoltage Measurement With Dielectric WindowIEEE Transactions on Power Delivery, 2014
- Influence of the Switching Speed of the Disconnector on Very Fast Transient OvervoltageIEEE Transactions on Power Delivery, 2013
- Experimental Research on Very-Fast Transient Overvoltage in 1100-kV Gas-Insulated SwitchgearIEEE Transactions on Power Delivery, 2012
- Response of metal oxide arrester in gas-insulated substation and methods to improve its dynamic characteristicsIET Science, Measurement & Technology, 2012
- Modelling of metal oxide arrester for very fast transientsIET Science, Measurement & Technology, 2011
- A simplified model for zinc oxide surge arrestersIEEE Transactions on Power Delivery, 1999
- Modeling of metal oxide surge arrestersIEEE Transactions on Power Delivery, 1992