Comparison of a New Multiplex Binding Assay versus the Enzyme-Linked Immunosorbent Assay for Measurement of Serotype-Specific Pneumococcal Capsular Polysaccharide IgG
Authors:
- 3 August 2011
- journal article
- research article
- Published by American Society for Microbiology in Clinical and Vaccine Immunology
- Vol. 18 (10) , 1744-1751
Abstract
The measurement of serotype-specific anti-capsular polysaccharide antibodies remains the mainstay of pneumococcal (Pn) vaccine evaluation. New methods that allow the simultaneous measurement of antibodies to several antigens in small volumes of serum, and that agree well with existing techniques, are urgently required to support the increasing number of concomitant vaccines delivered in the infant immunization schedules and the use of extended-valency Pn vaccines. We therefore compared a relatively new multiplexed platform for measuring anti-Pn antibodies with the existing WHO consensus enzyme-linked immunosorbent assay (ELISA). A panel of 50 pediatric samples (34 collected after receipt of a heptavalent pneumococcal conjugate vaccine [PCV7] and 16 without PCV7) was analyzed across two different laboratories using a new multiplex electrochemiluminescence (ECL)-based detection assay developed for the quantitation of IgG serotype-specific antipneumococcal antibodies, and the results were compared to those obtained using the WHO consensus ELISA. For the seven serotypes measured, there was good agreement between the techniques and laboratories. The most notable difference was found between the ECL assay and the ELISA: concentrations tended to be higher in the ECL assay. For serotypes 6B, 9V, 18C, and 23F, the average increases in concentration ranged from 48 to 102%. However, the agreement rates on the proportions of samples with concentrations surrounding 0.35 μg/ml were >82% for all serotypes tested. Agreement between the two laboratories running the ECL assay was generally good: agreement on proportions of samples with concentrations surrounding 0.35 μg/ml was in excess of 92%, and agreement on average antibody concentrations was within 31%. We conclude that the Meso Scale Discovery (MSD) platform provides a promising new technique for the simultaneous measurement of antipneumococcal antibodies.Keywords
This publication has 17 references indexed in Scilit:
- Interlaboratory Comparison of Three Multiplexed Bead-Based Immunoassays for Measuring Serum Antibodies to Pneumococcal PolysaccharidesClinical and Vaccine Immunology, 2010
- Optimization and Validation of a Multiplex, Electrochemiluminescence-Based Detection Assay for the Quantitation of Immunoglobulin G Serotype-Specific Antipneumococcal Antibodies in Human SerumClinical and Vaccine Immunology, 2009
- A 22-plex Chemiluminescent Microarray for Pneumococcal AntibodiesAmerican Journal of Clinical Pathology, 2007
- Estimating the protective concentration of anti-pneumococcal capsular polysaccharide antibodiesVaccine, 2007
- Method for Simultaneous Measurement of Antibodies to 23 Pneumococcal Capsular PolysaccharidesClinical and Vaccine Immunology, 2003
- Enzyme-Linked Immunosorbent Assay for Quantitation of Human Antibodies to Pneumococcal PolysaccharidesClinical and Vaccine Immunology, 2003
- A Multiplexed Fluorescent Microsphere Immunoassay for Antibodies to Pneumococcal Capsular PolysaccharidesAmerican Journal of Clinical Pathology, 2002
- Efficacy, safety and immunogenicity of heptavalent pneumococcal conjugate vaccine in childrenThe Pediatric Infectious Disease Journal, 2000
- Measurement-Methods Comparisons and Linear Statistical RelationshipTechnometrics, 1999
- A new non-isotopic detection system for immunoassaysNature, 1995