Theoretical and Experimental Analysis on Influence of Natural Airflow on Spent Fuel Heat Removal in Dry Cask Storage
Authors:
- Ratiko RatikoRRRatiko Ratiko
- Raden SumarbagionoRSRaden Sumarbagiono
- Aisyah AisyahAAAisyah Aisyah
- Wati WatiWati Wati
- Kuat HeriyantoKHKuat Heriyanto
- Mirawaty MirawatyMMMirawaty Mirawaty
- Pungky Ayu ArtianiPAPungky Ayu Artiani
- Yuli PurwantoYuli Purwanto
- Dwi Luhur Ibnu SaputraDSDwi Luhur Ibnu Saputra
- Jaka RachmadetinJRJaka Rachmadetin
- Risdiyana SetiawanRSRisdiyana Setiawan
- Arifin IstavaraArifin Istavara
Open Access
- 6 February 2022
- journal article
- research article
- Published by MDPI AG in Sustainability
- Vol. 14 (3) , 1859
Abstract
A key issue contributing to the success of NPP technology is the safe handling of radioactive waste, particularly spent nuclear fuel. According to the IAEA safety standard, the spent fuel must be stored in interim wet storage for several years so the radiation and the decay heat of the spent fuel will decrease to the safe limit values, after which the spent fuel can be moved to dry storage. In this study, we performed a theoretical analysis of heat removal by natural convection airflow in spent nuclear fuel dry storage. The temperature difference between the air inside and outside dry storage produces an air density difference. The air density difference causes a pressure difference, which then generates natural airflow. The result of the theoretical analysis was validated with simulation software and experimental investigation using a reduced-scale dry storage prototype. The dry storage prototype consisted of a dry cask body and two canisters stacked to store materials testing reactor (MTR) spent fuel, which generates decay heat. The cask body had four air inlet vents on the bottom and four air outlet vents at the top. To simulate the decay heat from the spent fuel in the two canisters, the canisters were wrapped with an electric wire heater that was connected to a voltage regulator to adjust the heat power. The theoretical analysis results of this study are relatively consistent with the experimental results, with the mean relative deviation (MRD) values for the prediction of air velocity, the heat rate using natural airflow, and the heat rate using the thermal resistance network equation are +0.76, −23.69, and −29.54%, respectively.Keywords
Funding Information
- The Ministry of Research and Higher Education of Indonesia under the PPTI 2021 Program (3/ PPK/E4/2021)
This publication has 22 references indexed in Scilit:
- Minimizing the Standard Deviation of the Thermal Load in the Spent Nuclear Fuel Cask Loading ProblemEnergies, 2020
- Heat transfer enhancement in dry cask storage for nuclear spent fuel using additive high density inert gasAnnals of Nuclear Energy, 2019
- Modeling of decay heat removal from CONSTOR RBMK-1500 casks during long-term storage of spent nuclear fuelEnergy, 2019
- Quantification of the impact of temperature difference between two connected indoor spaces on 222Rn concentrationBuilding and Environment, 2019
- Thermal state of ventilated storage container with spent nuclear fuel under normal operationInternational Journal of Nuclear Energy Science and Technology, 2019
- Optimization of Dry Storage for Spent Fuel from G.A. Siwabessy Nuclear Research ReactorInternational Journal of Technology, 2018
- Numerical Simulation of the Thermal Performance of a Dry Storage Cask for Spent Nuclear FuelEnergies, 2018
- Thermal modeling of a vertical dry storage cask for used nuclear fuelNuclear Engineering and Design, 2016
- Experimental investigation of heat removal performance of a concrete storage caskAnnals of Nuclear Energy, 2015
- Storage and final disposal of spent htr fuel in the federal republic of GermanyNuclear Engineering and Design, 1990