Effect of material type, torque value, and sterilization on linear displacements of a scan body: An in vitro study
Open Access
- 10 February 2023
- journal article
- research article
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 25 (2) , 419-425
Abstract
Background: There is limited knowledge on the effect of scan body (SB) material type, torque value, and sterilization on linear displacements of implant SBs.Purpose: To evaluate the effect of material type, torque value, and sterilization on linear displacements of SBs during screw tightening by using digital image correlation (DIC) analysis.Materials and Methods: One polyetheretherketone (PEEK, Zfx Intraoral Scan Body) and one titanium SB (Ti, MPS Zimmer Scanbody R1410) were tightened with 5 Ncm torque on two implants (Zimmer TSV ⌀4.7 mm) by using a digital torque limiting device. SBs' initial spatial positions relative to the implants were recorded by using 3D DIC technique. Measurements were repeated after initially increasing torque value to 10 Ncm and then to 15 Ncm, and these steps were repeated for a total of 10 PEEK and 10 Ti SBs on both implants (n = 20). All SBs were then sterilized 25 times by using an autoclave (STATIM 5000 S G4) according to manufacturer's recommendations and all measurements were repeated. Linear displacements on three axes were calculated for each SB with increasing torque values (from 5 to 10 Ncm and from 10 to 15 Ncm) before and after sterilization. SB displacements within each torque value–sterilization pair were compared by using Mann–Whitney U test, whereas Wilcoxon signed‐rank test was used to compare SB displacements within each material–torque value pair between conditions and within each material–sterilization pair between torque values (α = 0.05).Results: On x‐axis, PEEK SBs had higher displacements than Ti SBs (p < 0.001), whereas sterilization (p ≤ 0.028) and 15 Ncm torque application (p ≤ 0.006) led to higher displacements of PEEK SBs. On y‐axis, PEEK SBs had higher displacements than Ti SBs with 15 Ncm torque application (p ≤ 0.033). A total of 15 Ncm torque‐applied PEEK SBs and 10 Ncm torque‐applied Ti SBs had higher displacements after sterilization (p ≤ 0.028). Application of 15 Ncm torque led to higher displacements regardless of the material (p ≤ 0.002). On z‐axis, PEEK SBs had higher displacements (p ≤ 0.015), except for 10 Ncm torque‐applied sterilized SBs (p = 0.102). With 10 Ncm torque application, sterilization decreased the displacement values of PEEK SBs (p = 0.044). Greater displacements were observed with 10 Ncm torque‐applied Ti SBs before sterilization and 15 Ncm torque‐applied PEEK SBs after sterilization (p ≤ 0.033).Conclusions: Axial displacement of SBs was affected by material type, torque value, and sterilization. Ti SBs mostly had lower displacements than PEEK SBs. Application of 15 Ncm torque to tested PEEK SBs should be refrained from and a calibrated tightening tool may enable the application of 10 Ncm or lower torque values for lower displacements. Sterilization generally increased PEEK SB displacements.Keywords
This publication has 23 references indexed in Scilit:
- Displacement comparison of CAD–CAM titanium and zirconia abutments to implants with different conical connectionsJournal of Prosthodontic Research, 2018
- Comparison of 3D displacements of screw-retained zirconia implant crowns into implants with different internal connections with respect to screw tighteningThe Journal of Prosthetic Dentistry, 2018
- Clinician-generated torque on abutment screws using different hand screwdriversThe Journal of Prosthetic Dentistry, 2017
- In vivo precision of conventional and digital methods of obtaining complete-arch dental impressionsThe Journal of Prosthetic Dentistry, 2016
- Three-Dimensional Displacement of Nine Different Abutments for an Implant with an Internal Hexagon PlatformThe International Journal of Oral and Maxillofacial Implants, 2015
- Accuracy Comparison of Implant Impression Techniques: A Systematic ReviewClinical Implant Dentistry and Related Research, 2015
- Displacement of Screw-Retained Splinted and Nonsplinted Restorations into Implants with Conical Internal ConnectionsThe International Journal of Oral and Maxillofacial Implants, 2014
- Displacement of Screw-Retained Single Crowns into Implants with Conical Internal ConnectionsThe International Journal of Oral and Maxillofacial Implants, 2013
- Cement fixation and screw retention: parameters of passive fitClinical Oral Implants Research, 2004
- Implant Screw Mechanics and the Settling Effect: An OverviewJournal of Oral Implantology, 2003