Jeremy Seidt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jeremy Seidt has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Amos Gilat
The Ohio State University
4 shared publications - Nathan Spulak
Department of Mechanical and Aerospace Engineering, The University of Alabama in Huntsville 2 , 301 Sparkman Dr., Huntsville AL 35899
2 shared publications Amir Oueslati
1 shared publicationAmos Gilat
1 shared publication- Bryson Knott1 shared publication
- Burak Yilmaz
Department of Reconstructive Dentistry and Gerodontology School of Dental Medicine University of Bern Bern Switzerland
1 shared publication
Latest Publications
- Open Access
- 2 July 2026
- Published by Elsevier in Engineering Fracture Mechanics
- Vol. 345
Ductile fracture of 2024-T351 aluminum and Ti-6Al-4V under plane strain compression
- 2 July 2026
- Published by Elsevier in Engineering Fracture Mechanics
- Vol. 345
Open AccessDuctile fracture of 2024-T351 aluminum and Ti-6Al-4V under plane strain compression
- Open Access
- 27 February 2025
- Published by Elsevier in Journal of the Mechanics and Physics of Solids
- Vol. 199
Taylor-Quinney coefficient determination from simultaneous strain and temperature measurements of uniform and localized deformation in tensile tests
- 27 February 2025
- Published by Elsevier in Journal of the Mechanics and Physics of Solids
- Vol. 199
Open AccessTaylor-Quinney coefficient determination from simultaneous strain and temperature measurements of uniform and localized deformation in tensile tests
- Open Access
- 21 February 2025
- Published by Elsevier in International Journal of Impact Engineering
- Vol. 201
Direct impact Hopkinson compression bar experiment for testing at a strain rate of 50,000 s-1
- 21 February 2025
- Published by Elsevier in International Journal of Impact Engineering
- Vol. 201
Open AccessDirect impact Hopkinson compression bar experiment for testing at a strain rate of 50,000 s-1
- Open Access
- 10 February 2023
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 25 (2) , 419-425
Effect of material type, torque value, and sterilization on linear displacements of a scan body: An in vitro study
Background: There is limited knowledge on the effect of scan body (SB) material type, torque value, and sterilization on linear displacements of implant SBs.Purpose: To evaluate the effect of material type, torque value, and sterilization on linear displacements of SBs during screw tightening by using digital image correlation (DIC) analysis.Materials and Methods: One polyetheretherketone (PEEK, Zfx Intraoral Scan Body) and one titanium SB (Ti, MPS Zimmer Scanbody R1410) were tightened with 5 Ncm torque on two implants (Zimmer TSV ⌀4.7 mm) by using a digital torque limiting device. SBs' initial spatial positions relative to the implants were recorded by using 3D DIC technique. Measurements were repeated after initially increasing torque value to 10 Ncm and then to 15 Ncm, and these steps were repeated for a total of 10 PEEK and 10 Ti SBs on both implants (n = 20). All SBs were then sterilized 25 times by using an autoclave (STATIM 5000 S G4) according to manufacturer's recommendations and all measurements were repeated. Linear displacements on three axes were calculated for each SB with increasing torque values (from 5 to 10 Ncm and from 10 to 15 Ncm) before and after sterilization. SB displacements within each torque value–sterilization pair were compared by using Mann–Whitney U test, whereas Wilcoxon signed‐rank test was used to compare SB displacements within each material–torque value pair between conditions and within each material–sterilization pair between torque values (α = 0.05).Results: On x‐axis, PEEK SBs had higher displacements than Ti SBs (p < 0.001), whereas sterilization (p ≤ 0.028) and 15 Ncm torque application (p ≤ 0.006) led to higher displacements of PEEK SBs. On y‐axis, PEEK SBs had higher displacements than Ti SBs with 15 Ncm torque application (p ≤ 0.033). A total of 15 Ncm torque‐applied PEEK SBs and 10 Ncm torque‐applied Ti SBs had higher displacements after sterilization (p ≤ 0.028). Application of 15 Ncm torque led to higher displacements regardless of the material (p ≤ 0.002). On z‐axis, PEEK SBs had higher displacements (p ≤ 0.015), except for 10 Ncm torque‐applied sterilized SBs (p = 0.102). With 10 Ncm torque application, sterilization decreased the displacement values of PEEK SBs (p = 0.044). Greater displacements were observed with 10 Ncm torque‐applied Ti SBs before sterilization and 15 Ncm torque‐applied PEEK SBs after sterilization (p ≤ 0.033).Conclusions: Axial displacement of SBs was affected by material type, torque value, and sterilization. Ti SBs mostly had lower displacements than PEEK SBs. Application of 15 Ncm torque to tested PEEK SBs should be refrained from and a calibrated tightening tool may enable the application of 10 Ncm or lower torque values for lower displacements. Sterilization generally increased PEEK SB displacements.
- 10 February 2023
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 25 (2) , 419-425
Open AccessEffect of material type, torque value, and sterilization on linear displacements of a scan body: An in vitro study
Background: There is limited knowledge on the effect of scan body (SB) material type, torque value, and sterilization on linear displacements of implant SBs.Purpose: To evaluate the effect of material type, torque value, and sterilization on linear displacements of SBs during screw tightening by using digital image correlation (DIC) analysis.Materials and Methods: One polyetheretherketone (PEEK, Zfx Intraoral Scan Body) and one titanium SB (Ti, MPS Zimmer Scanbody R1410) were tightened with 5 Ncm torque on two implants (Zimmer TSV ⌀4.7 mm) by using a digital torque limiting device. SBs' initial spatial positions relative to the implants were recorded by using 3D DIC technique. Measurements were repeated after initially increasing torque value to 10 Ncm and then to 15 Ncm, and these steps were repeated for a total of 10 PEEK and 10 Ti SBs on both implants (n = 20). All SBs were then sterilized 25 times by using an autoclave (STATIM 5000 S G4) according to manufacturer's recommendations and all measurements were repeated. Linear displacements on three axes were calculated for each SB with increasing torque values (from 5 to 10 Ncm and from 10 to 15 Ncm) before and after sterilization. SB displacements within each torque value–sterilization pair were compared by using Mann–Whitney U test, whereas Wilcoxon signed‐rank test was used to compare SB displacements within each material–torque value pair between conditions and within each material–sterilization pair between torque values (α = 0.05).Results: On x‐axis, PEEK SBs had higher displacements than Ti SBs (p < 0.001), whereas sterilization (p ≤ 0.028) and 15 Ncm torque application (p ≤ 0.006) led to higher displacements of PEEK SBs. On y‐axis, PEEK SBs had higher displacements than Ti SBs with 15 Ncm torque application (p ≤ 0.033). A total of 15 Ncm torque‐applied PEEK SBs and 10 Ncm torque‐applied Ti SBs had higher displacements after sterilization (p ≤ 0.028). Application of 15 Ncm torque led to higher displacements regardless of the material (p ≤ 0.002). On z‐axis, PEEK SBs had higher displacements (p ≤ 0.015), except for 10 Ncm torque‐applied sterilized SBs (p = 0.102). With 10 Ncm torque application, sterilization decreased the displacement values of PEEK SBs (p = 0.044). Greater displacements were observed with 10 Ncm torque‐applied Ti SBs before sterilization and 15 Ncm torque‐applied PEEK SBs after sterilization (p ≤ 0.033).Conclusions: Axial displacement of SBs was affected by material type, torque value, and sterilization. Ti SBs mostly had lower displacements than PEEK SBs. Application of 15 Ncm torque to tested PEEK SBs should be refrained from and a calibrated tightening tool may enable the application of 10 Ncm or lower torque values for lower displacements. Sterilization generally increased PEEK SB displacements.
- 4 February 2023
- Published by Elsevier in Mechanics of Materials
- Vol. 179
Ductile fracture of 2024 aluminum under unequal biaxial in-plane tension and out-of-plane compression
- 4 February 2023
- Published by Elsevier in Mechanics of Materials
- Vol. 179
Ductile fracture of 2024 aluminum under unequal biaxial in-plane tension and out-of-plane compression
- 6 March 2019
- Published by Springer Nature in Experimental Mechanics
- Vol. 59 (5) , 725-731
A New Device for Tensile and Compressive Testing at Intermediate Strain Rates
- 6 March 2019
- Published by Springer Nature in Experimental Mechanics
- Vol. 59 (5) , 725-731
A New Device for Tensile and Compressive Testing at Intermediate Strain Rates
- 1 January 2009
- Published by ASME International
- p. 195-202
An Energy-Based Method for Uni-Axial Fatigue Life Calculation
An energy based fatigue life prediction framework has been developed for calculation of remaining fatigue life of in-service gas turbine materials. The purpose of the life prediction framework is to account for the material aging effect on fatigue strength of gas turbine engines structural components which are usually designed for infinite life. Previous studies [1–7] indicate the total strain energy dissipated during a monotonic fracture process and a cyclic process is a material property that can be determined by measuring the area underneath the monotonic true stress-strain curve and the sum of the area within each hysteresis loop in the cyclic process, respectively. The energy-based fatigue life prediction framework consists of the following entities: (1) development of a testing procedure to achieve plastic energy dissipation per life cycle and (2) incorporation of an energy-based fatigue life calculation scheme to determine the remaining fatigue life of in-service gas turbine materials. The accuracy of the remaining fatigue life prediction method was verified by comparison between model approximation and experimental results of Aluminum 6061-T6 (Al 6061-T6). The comparison shows promising agreement, thus validating the capability of the framework to produce accurate fatigue life prediction.
- 1 January 2009
- Published by ASME International
- p. 195-202
An Energy-Based Method for Uni-Axial Fatigue Life Calculation
An energy based fatigue life prediction framework has been developed for calculation of remaining fatigue life of in-service gas turbine materials. The purpose of the life prediction framework is to account for the material aging effect on fatigue strength of gas turbine engines structural components which are usually designed for infinite life. Previous studies [1–7] indicate the total strain energy dissipated during a monotonic fracture process and a cyclic process is a material property that can be determined by measuring the area underneath the monotonic true stress-strain curve and the sum of the area within each hysteresis loop in the cyclic process, respectively. The energy-based fatigue life prediction framework consists of the following entities: (1) development of a testing procedure to achieve plastic energy dissipation per life cycle and (2) incorporation of an energy-based fatigue life calculation scheme to determine the remaining fatigue life of in-service gas turbine materials. The accuracy of the remaining fatigue life prediction method was verified by comparison between model approximation and experimental results of Aluminum 6061-T6 (Al 6061-T6). The comparison shows promising agreement, thus validating the capability of the framework to produce accurate fatigue life prediction.