Quality of routine spirometry tests in Dutch general practices
Authors:
- Tjard Rj SchermerTSTjard Rj Schermer
- Alan J CrockettACAlan J Crockett
- Patrick Jp PoelsPPPatrick Jp Poels
- Jacob J van DijkeJDJacob J van Dijke
- Reinier P AkkermansRAReinier P Akkermans
- Hans F VlekHVHans F Vlek
- Willem R PietersWPWillem R Pieters
- 1 December 2009
- journal article
- Published by Royal College of General Practitioners in British Journal of General Practice
- Vol. 59 (569) , e376-e382
Abstract
Spirometry is an indispensable tool for diagnosis and monitoring of chronic airways disease in primary care. To establish the quality of routine spirometry tests in general practice, and explore associations between test quality and patient characteristics. Analysis of routine spirometry test records. Fifteen general practices which had a working agreement with a local hospital pulmonary function laboratory for spirometry assessment regarding test quality and interpretation. Spirometry tests were judged by a pulmonary function technician and a chest physician. Proportions of test adequacy were analysed using markers for manoeuvre acceptability and test reproducibility derived from the 1994 American Thoracic Society spirometry guideline. Associations between quality markers and age, sex, and severity of obstruction were examined using logistic regression. Practices performed a mean of four (standard deviation = 2) spirometry tests per week; 1271 tests from 1091 adult patients were analysed; 96.4% (95% confidence interval [CI] = 95.6 to 97.2) of all tests consisted of ≥3 blows. With 60.6% of tests, forced expiratory time was the marker with the lowest acceptability rate. An overall 38.8% (95% CI = 36.0 to 41.6) of the tests met the acceptability as well as reproducibility criteria. Age, sex, and severity of obstruction were associated with test quality markers. The quality of routine spirometry tests was better than in previous reports from primary care research settings, but there is still substantial room for improvement. Sufficient duration of forced expiratory time is the quality marker with the highest rate of inadequacy. Primary care professionals should be aware of patient characteristics that may diminish the quality of their spirometry tests. Further research is needed to establish to what extent spirometry tests that are inadequate, according to stringent international expert criteria, result in incorrect clinical interpretations in general practice.Keywords
This publication has 33 references indexed in Scilit:
- Spirometrie in de Nederlandse huisartsenpraktijkHuisarts en wetenschap, 2008
- A mixed methods study to compare models of spirometry delivery in primary care for patients at risk of COPDThorax, 2008
- Effect of primary-care spirometry on the diagnosis and management of COPDEuropean Respiratory Journal, 2006
- International Primary Care Respiratory Group (IPCRG) Guidelines: Management of Chronic Obstructive Pulmonary Disease (COPD)Primary Care Respiratory Journal, 2006
- Variation in spirometry utilization between trained general practitioners in practices equipped with a spirometerScandinavian Journal of Primary Health Care, 2006
- Quality control of spirometry: a lesson from the BRONCUS trialEuropean Respiratory Journal, 2005
- Office Spirometry in Primary Care Pediatrics: A Pilot StudyPediatrics, 2005
- Respiratory function testing: The impact of respiratory scientists on the training and support of primary health care providersRespirology, 2004
- Validity of spirometric testing in a general practice population of patients with chronic obstructive pulmonary disease (COPD)Thorax, 2003
- Improving the quality of spirometry in an epidemiological study The Renfrew–Paisley (Midspan) family studyPublic Health, 2000