Corneal Power Distribution and Functional Optical Zone Following Small Incision Lenticule Extraction for Myopia
Authors:
- Yishan QianYQYishan Qian
- Jia HuangJHJia Huang
- Xingtao ZhouXZXingtao Zhou
- Rewais Benjamin HannaRHRewais Benjamin Hanna
- 1 August 2015
- journal article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 31 (8) , 532-538
Abstract
PURPOSE: To evaluate corneal power distribution using the ray tracing method (corneal power) in eyes undergoing small incision lenticule extraction (SMILE) surgery and compare the functional optical zone with two lenticular sizes. METHODS: This retrospective study evaluated 128 patients who underwent SMILE for the correction of myopia and astigmatism with a lenticular diameter of 6.5 mm (the 6.5-mm group) and 6.2 mm (the 6.2-mm group). The data include refraction, correction, and corneal power obtained via a Scheimpflug camera from the pupil center to 8 mm. The surgically induced changes in corneal power (Δcorneal power) were compared to correction and Δrefraction. The functional optical zone was defined as the largest ring diameter when the difference between the ring power and the pupil center power was 1.50 diopters or less. The functional optical zone was compared between two lenticular diameter groups. RESULTS: Corneal power distribution was measured by the ray tracing method. In the 6.5-mm group (n = 100), Δcorneal power at 5 mm showed the smallest difference from Δrefraction and Δcorneal power at 0 mm exhibited the smallest difference from correction. In the 6.2-mm group (n = 28), Δcorneal power at 2 mm displayed the lowest dissimilarity from Δrefraction and Δcorneal power at 4 mm demonstrated the lowest dissimilarity from correction. There was no significant difference between the mean postoperative functional optical zones in either group when their spherical equivalents were matched. CONCLUSIONS: Total corneal refactive power can be used in the evaluation of surgically induced changes following SMILE. A lenticular diameter of 6.2 mm should be recommended for patients with high myopia because there is no functional difference in the optical zone. [ J Refract Surg. 2015;31(8):532–538.]Keywords
This publication has 21 references indexed in Scilit:
- Comparison of methods to measure corneal power for intraocular lens power calculation using a rotating Scheimpflug cameraJournal of Cataract & Refractive Surgery, 2013
- A Contralateral, Randomized Comparison of Optimized Prolate Ablation and Conventional LASIK for Myopia With the NIDEK Excimer Laser PlatformJournal of Refractive Surgery, 2012
- Total Corneal Power Estimation: Ray Tracing Method versus Gaussian Optics FormulaInvestigative Ophthalmology & Visual Science, 2011
- Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective studyBritish Journal of Ophthalmology, 2010
- Local Steepening in Peripheral Corneal Curvature After Corneal Refractive Therapy and LASIKOptometry and Vision Science, 2010
- Functional Optical Zone of the CorneaInvestigative Ophthalmology & Visual Science, 2007
- Size of Corneal Topographic Effective Optical Zone: Comparison of Standard and Customized Myopic Laser In Situ KeratomileusisAmerican Journal of Ophthalmology, 2006
- Correlations Between Central and Peripheral Changes in Anterior Corneal Topography After Myopic LASIK and Their Implications in Postsurgical Contact Lens FittingEye & Contact Lens: Science & Clinical Practice, 2006
- The Topography of the Central and Peripheral CorneaInvestigative Ophthalmology & Visual Science, 2006
- Functional optical zone after myopic LASIK as a function of ablation diameterJournal of Cataract & Refractive Surgery, 2005