Abstract
A comparative numerical study is performed to assess the magnetohydrodynamic (MHD) flow behavior and pressure drop characteristics of two liquid metal (LM) supply system designs for a Dual Coolant Lead Lithium (DCLL) breeding blanket with electrically insulating walls. The two configurations differ primarily in the radial supply section: a conventional design employing separate inlet and outlet ducts, and an advanced design utilizing a single coaxial duct in which cold PbLi enters through a concentric annular gap and hot PbLi exits through an inner duct. The full blanket module is modeled, including radial ducts, expansion and contraction, U-turns, and long poloidal flow channels. Three-dimensional MHD simulations are carried out using a customized multiphysics model in COMSOL and a finite-volume solver implemented in OpenFOAM. The inductionless approximation is adopted, and computations are conducted over a wide range of Hartmann numbers (Ha = 384~3838 and Re = 620 in COMSOL, extended up to Ha = 11514 and Re = 24800 in OpenFOAM) to investigate pressure drop scaling, flow development, recirculation behavior, and mass flow distribution in the poloidal channels. The results show that both designs rapidly establish fully developed MHD flow in straight ducts, while strong three-dimensional effects and localized recirculation arise near expansions, contractions, and U-turns. At low Hartmann numbers, the conventional design yields a lower total pressure drop, primarily due to reduced MHD resistance in the radial ducts. However, as the magnetic field strength increases, the trend reverses; beyond a transition regime, the coaxial design exhibits a significantly lower overall pressure drop, achieving reductions of up to ~30% at Ha = 3838 and more than a factor of two at higher interaction numbers. The coaxial configuration also provides a more uniform flow distribution in the upward poloidal channels, particularly at high magnetic fields. These findings indicate that while the conventional design may be preferable at low magnetic fields and high inertia, the coaxial supply system becomes superior under fusion-relevant high-Ha conditions, offering substantial pressure drop mitigation and improved flow uniformity. The results provide important guidance for the optimization of liquid metal blanket supply systems in future fusion reactors.

This publication has 15 references indexed in Scilit: