Enhancement of contrast and resolution of B-mode plane wave imaging (PWI) with non-linear filtered delay multiply and sum (FDMAS) beamforming
- 3 November 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Abstract
FDMAS has been successfully used in microwave imaging for breast cancer detection. FDMAS gained its popularity due to its capability to produce results faster than any other adaptive beamforming technique such as minimum variance (MV) which requires higher computational complexity. The average computational time for single point spread function (PSF) at 40 mm depth for FDMAS is 87 times faster than MV. The new beamforming technique has been tested on PSF and cyst phantoms experimentally with the ultrasound array research platform version 2 (UARP II) using a 3–8 MHz 128 element clinical transducer. FDMAS is able to improve both imaging contrast and spatial resolution as compared to DAS. The wire phantom main lobes lateral resolution improved in FDMAS by 40.4% with square pulse excitation signal when compared to DAS. Meanwhile the contrast ratio (CR) obtained for an anechoic cyst located at 15 mm depth for PWI with DAS and FDMAS are −6.2 dB and −14.9 dB respectively. The ability to reduce noise from off axis with auto-correlation operation in FDMAS pave the way to display the B-mode image with high dynamic range. However, the contrast to noise ratio (CNR) measured at same cyst location for FDMAS give less reading compared to DAS. Nevertheless, this drawback can be compensated by applying compound plane wave imaging (CPWI) technique on FDMAS. In overall the new FDMAS beamforming technique outperforms DAS in laboratory experiments by narrowing its main lobes and increases the image contrast without sacrificing its frame rates.Keywords
This publication has 10 references indexed in Scilit:
- The Effect of the transducer parameters on spatial resolution in Plane-Wave imaging2015
- Comparison of spatial and temporal averaging on ultrafast imaging in presence of quantization errors2015
- The Delay Multiply and Sum Beamforming Algorithm in Ultrasound B-Mode Medical ImagingIEEE Transactions on Medical Imaging, 2014
- New performance metrics for ultrasound pulse compression systems2014
- Selecting the number and values of the CPWI steering angles and the effect of that on imaging quality2014
- The design of a high speed receiver system for an ultrasound array research platform2012
- Ultrasound array transmitter architecture with high timing resolution using embedded phase-locked loopsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2012
- Ultrasound speckle reduction using coded excitation, frequency compounding, and postprocessing despeckling filters2010
- Benefits of minimum-variance beamforming in medical ultrasound imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2009
- Confocal Microwave Imaging for Breast Cancer Detection: Delay-Multiply-and-Sum Image Reconstruction AlgorithmIEEE Transactions on Biomedical Engineering, 2008