Phase-Locked Loop Independent Second-Order Generalized Integrator for Single-Phase Grid Synchronization
- 12 August 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
Abstract
Second-order generalized integrator (SOGI) requires fast and accurate grid voltage frequency information for quadrature signal generation (QSG) in single-phase systems. Conventionally, synchronous reference frame phase-locked loop (PLL) (SRFPLL) is used in a cascade manner and provides frequency feedback to SOGI. PLL is a non-linear closed-loop control system that requires adequate gain parameter design trade-off to provide accurate grid synchronization. Additionally, it creates interdependent loops while estimating the grid frequency and phase-angle. This results in unwanted frequency disturbances during grid transients, such as voltage sag and phase-angle jumps (PAJs) which are fed back to the SOGI as well. Thus, this article proposes two PLL independent frequency-feeding approaches for SOGI: Type-A and -B. The frequency is estimated using the normalized single-phase grid voltage signal in both types. In Type-A, the normalization is done using cascaded recursive discrete-Fourier transform (RDFT) and inverse RDFT (IRDFT). On the other hand, in Type-B, SOGI outputs are used for normalization. The grid voltage amplitude is estimated using the absolute value of the in-phase and in-quadrature components of the proposed frequency-adaptive SOGI. Furthermore, the third-order polynomial approximation of the arctangent function is implemented for phase-angle estimation in both types. The performance of both the types during transients and steady-state grid voltage disturbances (dc offset and harmonics) are compared with SOGIPLL using both simulations and experiments.Keywords
This publication has 24 references indexed in Scilit:
- A Synchronization Scheme for Single-Phase Grid-Tied Inverters Under Harmonic Distortion and Grid DisturbancesIEEE Transactions on Power Electronics, 2016
- Optimizing of sampling in a low-cost single-phase instantaneous AC-grid synchronization unit with discrete calculation of derivative function2015
- Five Approaches to Deal With Problem of DC Offset in Phase-Locked Loop Algorithms: Design Considerations and Performance EvaluationsIEEE Transactions on Power Electronics, 2015
- Single-Phase Grid Voltage Frequency Estimation Using Teager Energy Operator-Based TechniqueIEEE Journal of Emerging and Selected Topics in Power Electronics, 2015
- Accurate Estimation of Single-Phase Grid Voltage Parameters Under Distorted ConditionsIEEE Transactions on Power Delivery, 2014
- Fault ride through requirements and measures of distributed PV systems in Japan2012
- Overview of Control and Grid Synchronization for Distributed Power Generation SystemsIEEE Transactions on Industrial Electronics, 2006
- A Method for Synchronization of Power Electronic Converters in Polluted and Variable-Frequency EnvironmentsIEEE Transactions on Power Systems, 2004
- A grid simulator with control of single-phase power converters in D-Q rotating frame2003
- A nonlinear adaptive filter for online signal analysis in power systems: applicationsIEEE Transactions on Power Delivery, 2002