Animesh Kumar Sahoo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Animesh Kumar Sahoo has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Jayashri Ravishankar
School of Electrical Engineering and Telecommunications, The University of New South Wales, Sydney, Australia
4 shared publications - Khizir Mahmud
School of Engineering and Telecommunications, University of New South Wales, Sydney, New South Wales Australia 2052
4 shared publications - Frede Blaabjerg
Aalborg University
2 shared publications Pratyasa Bhui
Department of Electrical, Electronics, and Communication Engineering, IIT Dharwad Karnataka
2 shared publications- Pratyasa Bhui
Department of Electrical, Electronics and Communication Engineering, Indian Institute of Technology Dharwad, Dharwad, India
2 shared publications - Sanjeevikumar Padmanaban
Department of Electrical Engineering, IT and Cybernetics, University of South-Eastern Norway, Porsgrunn, Norway
2 shared publications
Latest Publications
- 18 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (1) , 516-526
Experiences With Controlled Islanding and Relay Coordination in Lalitpur Power System, India
The formation of a power island, encompassing generating plants and nearby critical loads, is a strategy employed to maintain the operation of generating plants and the supply of power to essential services during potential blackouts. This paper presents a robust frequency stabilization strategy for such islands during blackouts in the main grid. The proposed methodology includes: (i) a three-stage under-frequency load shedding (UFLS) scheme that disconnects loads in large blocks to limit frequency decline; (ii) reconnection of shedded loads in smaller blocks in case of frequency rise after load shedding to maintain generationload balance; and (iii) a selective generator tripping scheme based on the estimated time to critical frequency, improving over traditional frequency or ROCOF-based methods. Load shedding locations are selected using voltage security criteria, and the entire protection scheme operates using only local measurements, removing reliance on communication infrastructure. The relay settings were tested in PSS/E for system data of Agra-Lalitpur region of Indian grid including renewables for varying operating conditions. It was also found that with grid supporting renewables, the frequency nadir improves with increasing renewables while frequency droop does not have much impact. The results have been shared with, and accepted by, the utility for potential implementation in the future.
- 18 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (1) , 516-526
Experiences With Controlled Islanding and Relay Coordination in Lalitpur Power System, India
The formation of a power island, encompassing generating plants and nearby critical loads, is a strategy employed to maintain the operation of generating plants and the supply of power to essential services during potential blackouts. This paper presents a robust frequency stabilization strategy for such islands during blackouts in the main grid. The proposed methodology includes: (i) a three-stage under-frequency load shedding (UFLS) scheme that disconnects loads in large blocks to limit frequency decline; (ii) reconnection of shedded loads in smaller blocks in case of frequency rise after load shedding to maintain generationload balance; and (iii) a selective generator tripping scheme based on the estimated time to critical frequency, improving over traditional frequency or ROCOF-based methods. Load shedding locations are selected using voltage security criteria, and the entire protection scheme operates using only local measurements, removing reliance on communication infrastructure. The relay settings were tested in PSS/E for system data of Agra-Lalitpur region of Indian grid including renewables for varying operating conditions. It was also found that with grid supporting renewables, the frequency nadir improves with increasing renewables while frequency droop does not have much impact. The results have been shared with, and accepted by, the utility for potential implementation in the future.
- Open Access
- 24 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Detailed Phasor Modelling of Grid Forming Proton Exchange Membrane (PEM) Electrolyzer Load
Hydrogen electrolyzers can serve as grid-forming load, help integrating variable renewable energy sources into the power grids by providing essential support during grid fluctuations. Existing literature has focused on isolated proton exchange membrane (PEM) electrolyzer models and, to some extent, grid-connected setups using electromagnetic transient (EMT) model. Phasor models are computationally efficient, ideal for largescale power system studies, significantly reduce simulation times compared to EMT models. This paper proposes a comprehensive model of a grid-connected PEM hydrogen electrolyzer including the DC side electrochemical and electrical behavior of the electrolyzer and AC side phasor model and droop control of inverter simultaneously. Electrochemical dynamics of the DC side is modeled in detail including the operational constraints and DC link voltage control. An aggregated converter model consists of 220 droop-controlled modules each having 500 kVA rating is used for grid connection of the electrolyzer in Kundur's Two-Area Four-Machine Test System. This paper also studies the impact of grid-forming services and grid disturbances on the electrolyzer's physical features such as hydrogen stack voltage, temperature, and efficiency
- 24 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessDetailed Phasor Modelling of Grid Forming Proton Exchange Membrane (PEM) Electrolyzer Load
Hydrogen electrolyzers can serve as grid-forming load, help integrating variable renewable energy sources into the power grids by providing essential support during grid fluctuations. Existing literature has focused on isolated proton exchange membrane (PEM) electrolyzer models and, to some extent, grid-connected setups using electromagnetic transient (EMT) model. Phasor models are computationally efficient, ideal for largescale power system studies, significantly reduce simulation times compared to EMT models. This paper proposes a comprehensive model of a grid-connected PEM hydrogen electrolyzer including the DC side electrochemical and electrical behavior of the electrolyzer and AC side phasor model and droop control of inverter simultaneously. Electrochemical dynamics of the DC side is modeled in detail including the operational constraints and DC link voltage control. An aggregated converter model consists of 220 droop-controlled modules each having 500 kVA rating is used for grid connection of the electrolyzer in Kundur's Two-Area Four-Machine Test System. This paper also studies the impact of grid-forming services and grid disturbances on the electrolyzer's physical features such as hydrogen stack voltage, temperature, and efficiency
- Open Access
- 24 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Enhanced Fault Current Utilization by Grid-forming Inverter using Non-linear Transient Virtual Resistance during Symmetrical Faults
The next-generation grid-forming inverters are more prone to overcurrent issues during grid faults due to their voltage source behaviour behind the impedance. This issue can be overcome by using the virtual resistance (VR) drop feedback and reconstructing the voltage reference for the inverter. Existing literature prefers transient VR (TVR) over VR to avoid the risk of transient instability. This paper proposes a novel nonlinear transient virtual resistance (NLTVR) method to restrict the fault current for the droop-controlled grid-forming threephase inverter modelled in the stationary reference frame. The parameter design of the proposed NLTVR method is analyzed and the optimum selection is evaluated in a wide range of grid strengths as well as fault severity. Additionally, the low voltage ride-through (LVRT) performance of the inverter, along with the proposed method in the case of a symmetrical fault, is simulated and compared using MATLAB/Simulink. The results demonstrate that the proposed method improves the maximum fault current utilization capability of the inverter in comparison to state-of-the-art linear and non-linear TVR methods during faults.
- 24 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessEnhanced Fault Current Utilization by Grid-forming Inverter using Non-linear Transient Virtual Resistance during Symmetrical Faults
The next-generation grid-forming inverters are more prone to overcurrent issues during grid faults due to their voltage source behaviour behind the impedance. This issue can be overcome by using the virtual resistance (VR) drop feedback and reconstructing the voltage reference for the inverter. Existing literature prefers transient VR (TVR) over VR to avoid the risk of transient instability. This paper proposes a novel nonlinear transient virtual resistance (NLTVR) method to restrict the fault current for the droop-controlled grid-forming threephase inverter modelled in the stationary reference frame. The parameter design of the proposed NLTVR method is analyzed and the optimum selection is evaluated in a wide range of grid strengths as well as fault severity. Additionally, the low voltage ride-through (LVRT) performance of the inverter, along with the proposed method in the case of a symmetrical fault, is simulated and compared using MATLAB/Simulink. The results demonstrate that the proposed method improves the maximum fault current utilization capability of the inverter in comparison to state-of-the-art linear and non-linear TVR methods during faults.
- Open Access
- 24 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Linear Phase-locked Loop based Hybrid Grid Synchronization for Grid-Forming Inverters
The next generation grid-forming (GFM) inverterbased resources (IBRs) suffer from grid synchronization issues during their grid integration to a stiff grid or in the event of severe grid faults. Thus, this paper introduces an improved hybrid power and voltage synchronization scheme for a threephase droop-controlled GFM inverter. During normal grid operation, Active Power Loop (APL) based synchronization is used. However, during grid connection (breaker operation), or transients such as voltage dip because of grid fault, linear phaselocked loop (LPLL) based voltage synchronization scheme is enabled to avoid high active and reactive power swings. To ensure smooth transition between the synchronization strategies, two frameworks are proposed. The first scheme is enabled by monitoring only voltage magnitude and the second one rely on both voltage magnitude and phase-angle error during faults. The proposed schemes leverage the linearity of the PLL implementation and avoid the trade-off-based bandwidth design of the classical synchronous referenced frame-based PLL (SRFPLL) depending upon grid conditions. The improved hybrid grid synchronization along with the two transition schemes is modelled, simulated and compared with the state-of-the-art hybrid synchronization scheme. It is observed that the GFM inverter achieves faster re-synchronization during both the inception and post grid fault event, facilitated by the proposed smooth transition-based hybrid grid synchronization.
- 24 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessLinear Phase-locked Loop based Hybrid Grid Synchronization for Grid-Forming Inverters
The next generation grid-forming (GFM) inverterbased resources (IBRs) suffer from grid synchronization issues during their grid integration to a stiff grid or in the event of severe grid faults. Thus, this paper introduces an improved hybrid power and voltage synchronization scheme for a threephase droop-controlled GFM inverter. During normal grid operation, Active Power Loop (APL) based synchronization is used. However, during grid connection (breaker operation), or transients such as voltage dip because of grid fault, linear phaselocked loop (LPLL) based voltage synchronization scheme is enabled to avoid high active and reactive power swings. To ensure smooth transition between the synchronization strategies, two frameworks are proposed. The first scheme is enabled by monitoring only voltage magnitude and the second one rely on both voltage magnitude and phase-angle error during faults. The proposed schemes leverage the linearity of the PLL implementation and avoid the trade-off-based bandwidth design of the classical synchronous referenced frame-based PLL (SRFPLL) depending upon grid conditions. The improved hybrid grid synchronization along with the two transition schemes is modelled, simulated and compared with the state-of-the-art hybrid synchronization scheme. It is observed that the GFM inverter achieves faster re-synchronization during both the inception and post grid fault event, facilitated by the proposed smooth transition-based hybrid grid synchronization.
- Open Access
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 58870-58886
Overcurrent Limitation and Enhanced Fault Current Utilization by Grid-Forming Inverter Using Hybrid Methods During Short Circuit Faults
The next-generation grid-forming (GFM) inverters face significant over-current and over-voltage challenges during grid faults due to their inherent voltage source behaviour behind impedance. These challenges are mitigated by simultaneously reconstructing power, voltage, or current references fed to different control layers in a coordinated way, known as the hybrid method. However, existing hybrid methods fail to a) ensure maximum fault current utilization and b) provide improved post-fault recovery. This paper proposes two new hybrid methods to address these limitations. The first method employs a novel non-linear transient virtual resistance (NLTVR) combined with reconstructed power references for symmetrical faults. An extension of NLTVR, referred to as unified NLTVR (UNLTVR), is introduced to handle both symmetrical and asymmetrical faults. By integrating NLTVR or UNLTVR with reconstructed power references based on grid fault severity, the inverter operates near its maximum current limit during faults while preserving GFM functionality, ensuring smooth post-fault power recovery without exceeding reference values. The second method combines the sinusoidal current reference limiter (SCRL) with the proposedUNLTVR. The proposed schemes are implemented in a droop-controlled GFM inverter modelled in the stationary reference frame. The effectiveness of the proposed methods is demonstrated through MATLAB/Simulink simulations of symmetrical and asymmetrical faults, supported by a Controller Hardware-in-the-Loop (CHIL) experiment. The proposed methods are also compared with conventional current-limiting methods. It is revealed that the SCRL achieves maximum fault current capability faster, while the combined efforts of the UNLTVR help the GFM inverter to experience a seamless post-fault recovery.
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 58870-58886
Open AccessOvercurrent Limitation and Enhanced Fault Current Utilization by Grid-Forming Inverter Using Hybrid Methods During Short Circuit Faults
The next-generation grid-forming (GFM) inverters face significant over-current and over-voltage challenges during grid faults due to their inherent voltage source behaviour behind impedance. These challenges are mitigated by simultaneously reconstructing power, voltage, or current references fed to different control layers in a coordinated way, known as the hybrid method. However, existing hybrid methods fail to a) ensure maximum fault current utilization and b) provide improved post-fault recovery. This paper proposes two new hybrid methods to address these limitations. The first method employs a novel non-linear transient virtual resistance (NLTVR) combined with reconstructed power references for symmetrical faults. An extension of NLTVR, referred to as unified NLTVR (UNLTVR), is introduced to handle both symmetrical and asymmetrical faults. By integrating NLTVR or UNLTVR with reconstructed power references based on grid fault severity, the inverter operates near its maximum current limit during faults while preserving GFM functionality, ensuring smooth post-fault power recovery without exceeding reference values. The second method combines the sinusoidal current reference limiter (SCRL) with the proposedUNLTVR. The proposed schemes are implemented in a droop-controlled GFM inverter modelled in the stationary reference frame. The effectiveness of the proposed methods is demonstrated through MATLAB/Simulink simulations of symmetrical and asymmetrical faults, supported by a Controller Hardware-in-the-Loop (CHIL) experiment. The proposed methods are also compared with conventional current-limiting methods. It is revealed that the SCRL achieves maximum fault current capability faster, while the combined efforts of the UNLTVR help the GFM inverter to experience a seamless post-fault recovery.
- 6 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Single-Phase Pseudo-Open-Loop Grid Voltage Attributes Tracking Scheme Based on Nonadaptive Linear-Phase Filters
In this article, an open-loop technique based on digital filtering is proposed for the extraction of single-phase grid voltage parameters. Further, it proposes the combination of modulated sliding discrete Fourier transform (mSDFT) with three distinct frequency estimators known as a) Linear phase-locked loop (LPLL), b) Two-point method, and c) Empirical method. Non-adaptive mSDFT is employed to provide the required fundamental orthogonal components rejecting the DC offset and harmonics. When the grid frequency drifts from its nominal value, to enhance harmonic rejection, two cascaded moving average filters (tuned to reject dominant harmonics) are included as pre-filters. With off-nominal grid frequency, due to attenuation offered by these fixed-frequency filters, the amplitude and phase of the in-phase and quadrature components will be different from the input values. Further, it was found that the ratio of peak values of these component is different for different frequencies and there exists a relation between this ratio and frequency deviation. Based on this finding, an algorithm for the estimation of frequency deviation and then to correct the amplitude and phase errors in feed-forward manner is developed. It is revealed that the estimator relying on the empirical method provides faster settling with comparatively higher overshoots. LPLL and two point method achieve less overshoots at the cost of additional delay in the estimations. Finally, real-time experimental validations considering various grid abnormalities are provided to support the simulation outcomes.
- 6 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Single-Phase Pseudo-Open-Loop Grid Voltage Attributes Tracking Scheme Based on Nonadaptive Linear-Phase Filters
In this article, an open-loop technique based on digital filtering is proposed for the extraction of single-phase grid voltage parameters. Further, it proposes the combination of modulated sliding discrete Fourier transform (mSDFT) with three distinct frequency estimators known as a) Linear phase-locked loop (LPLL), b) Two-point method, and c) Empirical method. Non-adaptive mSDFT is employed to provide the required fundamental orthogonal components rejecting the DC offset and harmonics. When the grid frequency drifts from its nominal value, to enhance harmonic rejection, two cascaded moving average filters (tuned to reject dominant harmonics) are included as pre-filters. With off-nominal grid frequency, due to attenuation offered by these fixed-frequency filters, the amplitude and phase of the in-phase and quadrature components will be different from the input values. Further, it was found that the ratio of peak values of these component is different for different frequencies and there exists a relation between this ratio and frequency deviation. Based on this finding, an algorithm for the estimation of frequency deviation and then to correct the amplitude and phase errors in feed-forward manner is developed. It is revealed that the estimator relying on the empirical method provides faster settling with comparatively higher overshoots. LPLL and two point method achieve less overshoots at the cost of additional delay in the estimations. Finally, real-time experimental validations considering various grid abnormalities are provided to support the simulation outcomes.
- 12 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
Phase-Locked Loop Independent Second-Order Generalized Integrator for Single-Phase Grid Synchronization
Second-order generalized integrator (SOGI) requires fast and accurate grid voltage frequency information for quadrature signal generation (QSG) in single-phase systems. Conventionally, synchronous reference frame phase-locked loop (PLL) (SRFPLL) is used in a cascade manner and provides frequency feedback to SOGI. PLL is a non-linear closed-loop control system that requires adequate gain parameter design trade-off to provide accurate grid synchronization. Additionally, it creates interdependent loops while estimating the grid frequency and phase-angle. This results in unwanted frequency disturbances during grid transients, such as voltage sag and phase-angle jumps (PAJs) which are fed back to the SOGI as well. Thus, this article proposes two PLL independent frequency-feeding approaches for SOGI: Type-A and -B. The frequency is estimated using the normalized single-phase grid voltage signal in both types. In Type-A, the normalization is done using cascaded recursive discrete-Fourier transform (RDFT) and inverse RDFT (IRDFT). On the other hand, in Type-B, SOGI outputs are used for normalization. The grid voltage amplitude is estimated using the absolute value of the in-phase and in-quadrature components of the proposed frequency-adaptive SOGI. Furthermore, the third-order polynomial approximation of the arctangent function is implemented for phase-angle estimation in both types. The performance of both the types during transients and steady-state grid voltage disturbances (dc offset and harmonics) are compared with SOGIPLL using both simulations and experiments.
- 12 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
Phase-Locked Loop Independent Second-Order Generalized Integrator for Single-Phase Grid Synchronization
Second-order generalized integrator (SOGI) requires fast and accurate grid voltage frequency information for quadrature signal generation (QSG) in single-phase systems. Conventionally, synchronous reference frame phase-locked loop (PLL) (SRFPLL) is used in a cascade manner and provides frequency feedback to SOGI. PLL is a non-linear closed-loop control system that requires adequate gain parameter design trade-off to provide accurate grid synchronization. Additionally, it creates interdependent loops while estimating the grid frequency and phase-angle. This results in unwanted frequency disturbances during grid transients, such as voltage sag and phase-angle jumps (PAJs) which are fed back to the SOGI as well. Thus, this article proposes two PLL independent frequency-feeding approaches for SOGI: Type-A and -B. The frequency is estimated using the normalized single-phase grid voltage signal in both types. In Type-A, the normalization is done using cascaded recursive discrete-Fourier transform (RDFT) and inverse RDFT (IRDFT). On the other hand, in Type-B, SOGI outputs are used for normalization. The grid voltage amplitude is estimated using the absolute value of the in-phase and in-quadrature components of the proposed frequency-adaptive SOGI. Furthermore, the third-order polynomial approximation of the arctangent function is implemented for phase-angle estimation in both types. The performance of both the types during transients and steady-state grid voltage disturbances (dc offset and harmonics) are compared with SOGIPLL using both simulations and experiments.
- 5 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
An Enhanced Frequency-Adaptive Single-Phase Grid Synchronization Technique
Second-order generalized integrator phase-locked loop (SOGIPLL) relies on the frequency feedback from the PLL estimation. The frequency is used to generate the equivalent in-phase and in-quadrature signals of the single-phase grid voltage. The phase-angle coupled frequency feedback makes the SOGIPLL structure vulnerable to various grid voltage transients such as voltage sag, phase-angle jumps (PAJs) and frequency variations. This paper proposes a PLL independent frequency estimation technique. It estimates the frequency using the simplified teager energy operation on the normalized in-phase voltage component output of the SOGI. The phase-angle is estimated using the third-order polynomial approximated arctangent function on the in-phase and in-quadrature outputs of the proposed frequency-adaptive SOGI. The grid synchronization technique presented in this work avoids the use of any trigonometric operations and PLL gain tuning issues. Additionally, the impact of steady-state grid disturbances, namely, harmonics and DC offset on the proposed synchronization technique is investigated. Finally, its performance robustness is compared with other techniques during both grid transients and steady-state disturbances using both simulation analysis and experimental validation.
- 5 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
An Enhanced Frequency-Adaptive Single-Phase Grid Synchronization Technique
Second-order generalized integrator phase-locked loop (SOGIPLL) relies on the frequency feedback from the PLL estimation. The frequency is used to generate the equivalent in-phase and in-quadrature signals of the single-phase grid voltage. The phase-angle coupled frequency feedback makes the SOGIPLL structure vulnerable to various grid voltage transients such as voltage sag, phase-angle jumps (PAJs) and frequency variations. This paper proposes a PLL independent frequency estimation technique. It estimates the frequency using the simplified teager energy operation on the normalized in-phase voltage component output of the SOGI. The phase-angle is estimated using the third-order polynomial approximated arctangent function on the in-phase and in-quadrature outputs of the proposed frequency-adaptive SOGI. The grid synchronization technique presented in this work avoids the use of any trigonometric operations and PLL gain tuning issues. Additionally, the impact of steady-state grid disturbances, namely, harmonics and DC offset on the proposed synchronization technique is investigated. Finally, its performance robustness is compared with other techniques during both grid transients and steady-state disturbances using both simulation analysis and experimental validation.
- 27 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (3) , 2829-2841
Enhanced Fault Ride-Through of Power Converters Using Hybrid Grid Synchronization
Inaccurate phase-angle jump estimation of the grid voltage during faults is one of the major causes for poor fault ride-through performance of converters. To overcome this issue and make the converter’s current controller robust, this paper proposes a hybrid grid synchronization transition technique. In this concept, a synchronous reference frame based phase-locked loop (SRFPLL) grid synchronization method is used during normal grid operation and switched to an arctangent based phase-angle estimation during grid faults. Simultaneously frequency estimation is switched to the arctangent derived frequency. A common transition method, which depends on the phase-angle error between the two phase estimation techniques, is proposed to ensure a smooth transition between the hybrid phase-angle and frequencies. The transition technique is implemented using the current control of a three-phase voltage source converter in the synchronous reference frame. The performance of the converter during both symmetrical and asymmetrical grid faults along with the fault ride-through strategies is tested using real-time experiments. It is observed that the transition based hybrid grid synchronization technique reduces the loss of synchronism duration. Additionally, it offers a more robust converter current control performance compared to the SRFPLL technique over a wide range of voltage sags and phase-angle jumps.
- 27 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (3) , 2829-2841
Enhanced Fault Ride-Through of Power Converters Using Hybrid Grid Synchronization
Inaccurate phase-angle jump estimation of the grid voltage during faults is one of the major causes for poor fault ride-through performance of converters. To overcome this issue and make the converter’s current controller robust, this paper proposes a hybrid grid synchronization transition technique. In this concept, a synchronous reference frame based phase-locked loop (SRFPLL) grid synchronization method is used during normal grid operation and switched to an arctangent based phase-angle estimation during grid faults. Simultaneously frequency estimation is switched to the arctangent derived frequency. A common transition method, which depends on the phase-angle error between the two phase estimation techniques, is proposed to ensure a smooth transition between the hybrid phase-angle and frequencies. The transition technique is implemented using the current control of a three-phase voltage source converter in the synchronous reference frame. The performance of the converter during both symmetrical and asymmetrical grid faults along with the fault ride-through strategies is tested using real-time experiments. It is observed that the transition based hybrid grid synchronization technique reduces the loss of synchronism duration. Additionally, it offers a more robust converter current control performance compared to the SRFPLL technique over a wide range of voltage sags and phase-angle jumps.
- 1 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 14 (3) , 3641-3652
Computational Tools for Modeling and Analysis of Power Generation and Transmission Systems of the Smart Grid
- 1 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 14 (3) , 3641-3652
Computational Tools for Modeling and Analysis of Power Generation and Transmission Systems of the Smart Grid