Standing 8-Electrode Bioelectrical Impedance Analysis as an Alternative Method to Estimate Visceral Fat Area and Body Fat Mass in Athletes
Open Access
- 1 February 2021
- journal article
- research article
- Published by Taylor & Francis in International Journal of General Medicine
- Vol. ume 14, 539-548
Abstract
Purpose: To investigate the potential of standing 8-electrode bioelectrical impedance analysis (BIA) for assessing visceral fat area (VFA) and body fat mass (BFM) in athletes. Materials and Methods: A total of 95 subjects (50 males and 45 females) were recruited. VFA and BFM measurements were obtained using three standing 8-electrode BIA devices, InBody230, InBody770, and IOI353. These acquired VFA and BFM were expressed as VFAIOI353, VFAInBody230, VFAInBody770 V, BFMIOI353, BFMInBody230, and BFMInBody770, respectively. As reference measurement, the VFA acquired from computer tomography (CT) was expressed as VFACT, and the BFM measured by dual-energy X-ray absorptiometry (DXA) was denoted as BFMDXA. Results: The coefficient of determination (r2) in regression analysis between the measurements by VFAIOI353, VFAInBody230, VFAInBody770 and VFACT were 0.425, 0.492, and 0.473, respectively. Also, the limits of agreement (LOA) obtained from Bland–Altman analysis were − 25.18 to 56.62, − 29.74 to 62.44, and − 32.96 to 71.93 cm2. For BFM, r2 in regression analysis between the measurements by BFMIOI353, BFMInBody230, BFMInBody770 and BMFDXA were 0.894, 0.950, and 0.955, respectively; LOA were − 7.21 to 5.75, − 4.70 to 4.05, and − 5.48 to 3.05 kg, respectively. Conclusion: The results showed when assessing BFM, these instruments delivered comparable measurements, and the degree of agreement ranged from excellent to moderate compared with the reference method. However, when assessing VFA, the agreements were weak. Therefore, the application of standing 8-electrode BIA devices for assessing athletes’ VFA still needs improvement.Keywords
This publication has 32 references indexed in Scilit:
- Comparison of Two Bioelectrical Impedance Analysis Devices With Dual Energy X-ray Absorptiometry and Magnetic Resonance Imaging in the Estimation of Body CompositionJournal of Strength & Conditioning Research, 2013
- Validity of a New Abdominal Bioelectrical Impedance Device to Measure Abdominal and Visceral Fat: Comparison With MRIObesity, 2010
- Development of a high-precision image-processing automatic measurement system for MRI visceral fat images acquired using a binomial RF-excitation pulseMagnetic Resonance Imaging, 2010
- Compatibility of different methods for the measurement of visceral fat in different body mass index strataDiagnostic and Interventional Radiology, 2009
- Is bioelectrical impedance accurate for use in large epidemiological studies?Nutrition Journal, 2008
- Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methodsMedical Engineering & Physics, 2008
- Accuracy of body mass index in diagnosing obesity in the adult general populationInternational Journal of Obesity, 2008
- Metabolic Syndrome: Connecting and Reconciling Cardiovascular and Diabetes WorldsJACC, 2006
- Assessing abdominal fatness with local bioimpedance analysis: basics and experimental findingsInternational Journal of Obesity, 2001
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986