Hsueh-Kuan Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hsueh-Kuan Lu has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Kuen-Chang Hsieh
Affiliations Big Data Center, National Chung Hsing University, Taichung City, Taiwan, Department of Research & Development, StarBIA Meditek Co., Ltd., Taichung City, Taiwan
6 shared publications - Chung-Liang Lai
Department of Physical Medicine and Rehabilitation, Puzi Hospital, Ministry of Health and Welfare, Chiayi, Taiwan
3 shared publications - Yu-Yawn Chen
National Taiwan University of Sport
3 shared publications - Lee-Ping Chu
Department of Orthopedics, China Medical University Hospital, Taichung 404, Taiwan
2 shared publications Ai-Chun Huang
Physical Education and Health Center, National Kaohsiung University of Hospitality and Tourism, Kaohsiung, Taiwan
1 shared publicationChih-Lin Chuang
Department of Radiology, Jen-Ai Hospital, Taichung, Taiwan
1 shared publication
Latest Publications
- Open Access
- 25 November 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-8
Comparison of whole body bone mineral density measurements between dual energy X-ray absorptiometry and novel bioelectrical impedance analysis
Bone mineral density (BMD) is a crucial indicator of osteoporosis. Bioelectrical impedance analysis (BIA) introduces a new method for assessing body composition, specifically BMD measurement. Compared with existing ultrasound and dual-energy X-ray absorptiometry for BMD screening and diagnosis, BIA has the advantages of safety, convenience and speed. However, the accuracy of BIA for BMD measurement needs to be explored. This study aimed to evaluate the accuracy of the novel BIA technique in conducting whole-body BMD assessments in the general population of Taiwan. Overall, 318 healthy adults in Taiwan (37.67 ± 19.44 years of age; 145 male and 173 female patients) were included. Whole-body BMD was measured via foot-to-foot BIA-StarBIA-201 (StarBIA Meditek Co. LTD, Taichung, Taiwan) and the dual-energy X-ray absorptiometry (DXA) Lunar Prodigy technology (GE Medical Systems, Madison, WI, USA). Linear regression analysis, Pearson’s correlation coefficient, the Bland–Altman plot, and paired t tests were used. The whole-body BMDs measured by BIA and DXA were 1.139 ± 0.124 g/cm2 and 1.202 ± 0.168 g/cm2, respectively. The regression equation was y = 1.057x + 0.063. The Pearson correlation coefficient, mean difference, and limits of agreement were r = 0.737, − 0.053 g/cm2, and − 0.290–0.165 g/cm2, respectively. The regression equation was y = 1.057x + 0.063. The Pearson correlation coefficient, mean difference, and limits of agreement were r = 0.737 (p < 0.001), − 0.053 g/cm2, and − 0.290–0.165 g/cm2, respectively. Standing BIA was correlated with the DXA gold standard for estimating whole-body BMD in adults; however, its interchangeability remains limited. The potential bias in the measurement results of this study represents a current challenge with BIA compared with that of DXA, and there is still room for improvement. The convenient BIA method for measuring whole-body BMD may be useful in the application of primary screening and future development of BMD assessment methods. BIA is widely used to measure body composition, but its application to the measurement of BMD represents a novel technological breakthrough.
- 25 November 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-8
Open AccessComparison of whole body bone mineral density measurements between dual energy X-ray absorptiometry and novel bioelectrical impedance analysis
Bone mineral density (BMD) is a crucial indicator of osteoporosis. Bioelectrical impedance analysis (BIA) introduces a new method for assessing body composition, specifically BMD measurement. Compared with existing ultrasound and dual-energy X-ray absorptiometry for BMD screening and diagnosis, BIA has the advantages of safety, convenience and speed. However, the accuracy of BIA for BMD measurement needs to be explored. This study aimed to evaluate the accuracy of the novel BIA technique in conducting whole-body BMD assessments in the general population of Taiwan. Overall, 318 healthy adults in Taiwan (37.67 ± 19.44 years of age; 145 male and 173 female patients) were included. Whole-body BMD was measured via foot-to-foot BIA-StarBIA-201 (StarBIA Meditek Co. LTD, Taichung, Taiwan) and the dual-energy X-ray absorptiometry (DXA) Lunar Prodigy technology (GE Medical Systems, Madison, WI, USA). Linear regression analysis, Pearson’s correlation coefficient, the Bland–Altman plot, and paired t tests were used. The whole-body BMDs measured by BIA and DXA were 1.139 ± 0.124 g/cm2 and 1.202 ± 0.168 g/cm2, respectively. The regression equation was y = 1.057x + 0.063. The Pearson correlation coefficient, mean difference, and limits of agreement were r = 0.737, − 0.053 g/cm2, and − 0.290–0.165 g/cm2, respectively. The regression equation was y = 1.057x + 0.063. The Pearson correlation coefficient, mean difference, and limits of agreement were r = 0.737 (p < 0.001), − 0.053 g/cm2, and − 0.290–0.165 g/cm2, respectively. Standing BIA was correlated with the DXA gold standard for estimating whole-body BMD in adults; however, its interchangeability remains limited. The potential bias in the measurement results of this study represents a current challenge with BIA compared with that of DXA, and there is still room for improvement. The convenient BIA method for measuring whole-body BMD may be useful in the application of primary screening and future development of BMD assessment methods. BIA is widely used to measure body composition, but its application to the measurement of BMD represents a novel technological breakthrough.
- Open Access
- 1 February 2021
- Published by Taylor & Francis in International Journal of General Medicine
- Vol. ume 14, 539-548
Standing 8-Electrode Bioelectrical Impedance Analysis as an Alternative Method to Estimate Visceral Fat Area and Body Fat Mass in Athletes
Purpose: To investigate the potential of standing 8-electrode bioelectrical impedance analysis (BIA) for assessing visceral fat area (VFA) and body fat mass (BFM) in athletes. Materials and Methods: A total of 95 subjects (50 males and 45 females) were recruited. VFA and BFM measurements were obtained using three standing 8-electrode BIA devices, InBody230, InBody770, and IOI353. These acquired VFA and BFM were expressed as VFAIOI353, VFAInBody230, VFAInBody770 V, BFMIOI353, BFMInBody230, and BFMInBody770, respectively. As reference measurement, the VFA acquired from computer tomography (CT) was expressed as VFACT, and the BFM measured by dual-energy X-ray absorptiometry (DXA) was denoted as BFMDXA. Results: The coefficient of determination (r2) in regression analysis between the measurements by VFAIOI353, VFAInBody230, VFAInBody770 and VFACT were 0.425, 0.492, and 0.473, respectively. Also, the limits of agreement (LOA) obtained from Bland–Altman analysis were − 25.18 to 56.62, − 29.74 to 62.44, and − 32.96 to 71.93 cm2. For BFM, r2 in regression analysis between the measurements by BFMIOI353, BFMInBody230, BFMInBody770 and BMFDXA were 0.894, 0.950, and 0.955, respectively; LOA were − 7.21 to 5.75, − 4.70 to 4.05, and − 5.48 to 3.05 kg, respectively. Conclusion: The results showed when assessing BFM, these instruments delivered comparable measurements, and the degree of agreement ranged from excellent to moderate compared with the reference method. However, when assessing VFA, the agreements were weak. Therefore, the application of standing 8-electrode BIA devices for assessing athletes’ VFA still needs improvement.
- 1 February 2021
- Published by Taylor & Francis in International Journal of General Medicine
- Vol. ume 14, 539-548
Open AccessStanding 8-Electrode Bioelectrical Impedance Analysis as an Alternative Method to Estimate Visceral Fat Area and Body Fat Mass in Athletes
Purpose: To investigate the potential of standing 8-electrode bioelectrical impedance analysis (BIA) for assessing visceral fat area (VFA) and body fat mass (BFM) in athletes. Materials and Methods: A total of 95 subjects (50 males and 45 females) were recruited. VFA and BFM measurements were obtained using three standing 8-electrode BIA devices, InBody230, InBody770, and IOI353. These acquired VFA and BFM were expressed as VFAIOI353, VFAInBody230, VFAInBody770 V, BFMIOI353, BFMInBody230, and BFMInBody770, respectively. As reference measurement, the VFA acquired from computer tomography (CT) was expressed as VFACT, and the BFM measured by dual-energy X-ray absorptiometry (DXA) was denoted as BFMDXA. Results: The coefficient of determination (r2) in regression analysis between the measurements by VFAIOI353, VFAInBody230, VFAInBody770 and VFACT were 0.425, 0.492, and 0.473, respectively. Also, the limits of agreement (LOA) obtained from Bland–Altman analysis were − 25.18 to 56.62, − 29.74 to 62.44, and − 32.96 to 71.93 cm2. For BFM, r2 in regression analysis between the measurements by BFMIOI353, BFMInBody230, BFMInBody770 and BMFDXA were 0.894, 0.950, and 0.955, respectively; LOA were − 7.21 to 5.75, − 4.70 to 4.05, and − 5.48 to 3.05 kg, respectively. Conclusion: The results showed when assessing BFM, these instruments delivered comparable measurements, and the degree of agreement ranged from excellent to moderate compared with the reference method. However, when assessing VFA, the agreements were weak. Therefore, the application of standing 8-electrode BIA devices for assessing athletes’ VFA still needs improvement.
- Open Access
- 10 April 2020
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 17 (7) , 2595
Comparison of Bioelectrical Impedance Analysis and Dual Energy X-ray Absorptiometry for Total and Segmental Bone Mineral Content with a Three-Compartment Model
Modern bioelectrical impedance analysis (BIA) provides a wide range of body composition estimates such as fat mass (FM), lean body mass (LBM), and body water, using specific algorithms. Assuming that the fat free mass (FFM) and LBM can be accurately estimated by the 8-electrode BIA analyzer (BIA8MF; InBody230, Biospace), the bone mineral content (BMC) may be calculated by subtracting the LBM from the FFM estimates based on the three-compartment (3C) model. In this cross-sectional study, 239 healthy Taiwanese adults (106 male and 133 female) aged 20–45 years were recruited for BIA and dual-energy X-ray absorptiometry (DXA) measurements of the whole body and body segments, with DXA as the reference. The results showed a high correlation between BIA8MF and DXA in estimating total and segmental LBM, FM and percentage body fat (r = 0.909–0.986, 0.757–0.964, and 0.837–0.936, respectively). For BMC estimates, moderate to high correlations (r = 0.425–0.829) between the two methods were noted. The percentage errors and pure errors for BMC estimates between the methods ranged from 33.9% to 93.0% and from 0.159 kg to 0.969 kg, respectively. This study validated that BIA8MF can accurately assesses LBM, FM and body fat percentage (BF%). However, the estimation of segmental BMC based on the difference between FFM and LBM in body segments may not be reliable by BIA8MF.
- 10 April 2020
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 17 (7) , 2595
Open AccessComparison of Bioelectrical Impedance Analysis and Dual Energy X-ray Absorptiometry for Total and Segmental Bone Mineral Content with a Three-Compartment Model
Modern bioelectrical impedance analysis (BIA) provides a wide range of body composition estimates such as fat mass (FM), lean body mass (LBM), and body water, using specific algorithms. Assuming that the fat free mass (FFM) and LBM can be accurately estimated by the 8-electrode BIA analyzer (BIA8MF; InBody230, Biospace), the bone mineral content (BMC) may be calculated by subtracting the LBM from the FFM estimates based on the three-compartment (3C) model. In this cross-sectional study, 239 healthy Taiwanese adults (106 male and 133 female) aged 20–45 years were recruited for BIA and dual-energy X-ray absorptiometry (DXA) measurements of the whole body and body segments, with DXA as the reference. The results showed a high correlation between BIA8MF and DXA in estimating total and segmental LBM, FM and percentage body fat (r = 0.909–0.986, 0.757–0.964, and 0.837–0.936, respectively). For BMC estimates, moderate to high correlations (r = 0.425–0.829) between the two methods were noted. The percentage errors and pure errors for BMC estimates between the methods ranged from 33.9% to 93.0% and from 0.159 kg to 0.969 kg, respectively. This study validated that BIA8MF can accurately assesses LBM, FM and body fat percentage (BF%). However, the estimation of segmental BMC based on the difference between FFM and LBM in body segments may not be reliable by BIA8MF.
- Open Access
Prediction and discrimination of skeletal muscle function by bioelectrical impedance vector analysis using a standing impedance analyzer in healthy Taiwanese adults
Background: Bioelectrical impedance vector analysis (BIVA) has been used for prediction of muscle performance. However, little is known about BIVA in Asian adults, and even less is known about using standing BIVA devices. Standing impedance analyzer allows quicker and more convenient way to gather data than conventional supine analyzer and is more suitable for clinical practice. This study aimed to investigate the relations between muscle function and BIVA parameters measured with a standing impedance analyzer in healthy Taiwanese adults. Methods: A total of 406 healthy subjects (age 34.5 ± 17.3 years, body mass index 24.1 ± 4.1 kg/m 2 ) were recruited for BIVA and handgrip strength (HGS) measurements. Impedance parameters, including resistance (R) and reactance (Xc), were measured and normalized to body size by dividing by height (H). The resulting phase angle (PhA) was calculated. HGS in the dominant, left, and right hands were referred to as HGS DH , HGS LH , and HGS RH , respectively. All subjects were divided into 5 grades according to HGS. Results: Muscle strength in the dominant, right, and left arms was correlated with variables in the order of sex, weight, age, height, Xc/H, and R/H (all, p < 0.001). Using all 6 variables, the determination coefficients were 0.792, 0.782, and 0.745, respectively, whereas the standard errors of estimates were 56.89, 58.01, and 56.67 N for HGS DH , HGS LH , and HGS RH , respectively. HGS was positively correlated with PhA, and negatively correlated with Xc/H and R/H. Conclusions: BIVA parameters measured with a standing impedance analyzer and anthropometric variables can predict and discriminate muscle function with good performance in healthy Asian adults.
Open AccessPrediction and discrimination of skeletal muscle function by bioelectrical impedance vector analysis using a standing impedance analyzer in healthy Taiwanese adults
Background: Bioelectrical impedance vector analysis (BIVA) has been used for prediction of muscle performance. However, little is known about BIVA in Asian adults, and even less is known about using standing BIVA devices. Standing impedance analyzer allows quicker and more convenient way to gather data than conventional supine analyzer and is more suitable for clinical practice. This study aimed to investigate the relations between muscle function and BIVA parameters measured with a standing impedance analyzer in healthy Taiwanese adults. Methods: A total of 406 healthy subjects (age 34.5 ± 17.3 years, body mass index 24.1 ± 4.1 kg/m 2 ) were recruited for BIVA and handgrip strength (HGS) measurements. Impedance parameters, including resistance (R) and reactance (Xc), were measured and normalized to body size by dividing by height (H). The resulting phase angle (PhA) was calculated. HGS in the dominant, left, and right hands were referred to as HGS DH , HGS LH , and HGS RH , respectively. All subjects were divided into 5 grades according to HGS. Results: Muscle strength in the dominant, right, and left arms was correlated with variables in the order of sex, weight, age, height, Xc/H, and R/H (all, p < 0.001). Using all 6 variables, the determination coefficients were 0.792, 0.782, and 0.745, respectively, whereas the standard errors of estimates were 56.89, 58.01, and 56.67 N for HGS DH , HGS LH , and HGS RH , respectively. HGS was positively correlated with PhA, and negatively correlated with Xc/H and R/H. Conclusions: BIVA parameters measured with a standing impedance analyzer and anthropometric variables can predict and discriminate muscle function with good performance in healthy Asian adults.
- Open Access
Hand-to-Hand Model for Bioelectrical Impedance Analysis to Estimate Fat Free Mass in a Healthy Population
This study aimed to establish a hand-to-hand (HH) model for bioelectrical impedance analysis (BIA) fat free mass (FFM) estimation by comparing with a standing position hand-to-foot (HF) BIA model and dual energy X-ray absorptiometry (DXA); we also verified the reliability of the newly developed model. A total of 704 healthy Chinese individuals (403 men and 301 women) participated. FFM (FFMDXA) reference variables were measured using DXA and segmental BIA. Further, regression analysis, Bland–Altman plots, and cross-validation (2/3 participants as the modeling group, 1/3 as the validation group; three turns were repeated for validation grouping) were conducted to compare tests of agreement with FFMDXA reference variables. In male participants, the hand-to-hand BIA model estimation equation was calculated as follows: FFMmHH = 0.537 h2/ZHH − 0.126 year + 0.217 weight + 18.235 (r2 = 0.919, standard estimate of error (SEE) = 2.164 kg, n = 269). The mean validated correlation coefficients and limits of agreement (LOAs) of the Bland–Altman analysis of the calculated values for FFMmHH and FFMDXA were 0.958 and −4.369–4.343 kg, respectively, for hand-to-foot BIA model measurements for men; the FFM (FFMmHF) and FFMDXA were 0.958 and −4.356–4.375 kg, respectively. The hand-to-hand BIA model estimating equation for female participants was FFMFHH = 0.615 h2/ZHH − 0.144 year + 0.132 weight + 16.507 (r2 = 0.870, SEE = 1.884 kg, n = 201); the three mean validated correlation coefficient and LOA for the hand-to-foot BIA model measurements for female participants (FFMFHH and FFMDXA) were 0.929 and −3.880–3.886 kg, respectively. The FFMHF and FFMDXA were 0.942 and −3.511–3.489 kg, respectively. The results of both hand-to-hand and hand-to-foot BIA models demonstrated similar reliability, and the hand-to-hand BIA models are practical for assessing FFM.
Open AccessHand-to-Hand Model for Bioelectrical Impedance Analysis to Estimate Fat Free Mass in a Healthy Population
This study aimed to establish a hand-to-hand (HH) model for bioelectrical impedance analysis (BIA) fat free mass (FFM) estimation by comparing with a standing position hand-to-foot (HF) BIA model and dual energy X-ray absorptiometry (DXA); we also verified the reliability of the newly developed model. A total of 704 healthy Chinese individuals (403 men and 301 women) participated. FFM (FFMDXA) reference variables were measured using DXA and segmental BIA. Further, regression analysis, Bland–Altman plots, and cross-validation (2/3 participants as the modeling group, 1/3 as the validation group; three turns were repeated for validation grouping) were conducted to compare tests of agreement with FFMDXA reference variables. In male participants, the hand-to-hand BIA model estimation equation was calculated as follows: FFMmHH = 0.537 h2/ZHH − 0.126 year + 0.217 weight + 18.235 (r2 = 0.919, standard estimate of error (SEE) = 2.164 kg, n = 269). The mean validated correlation coefficients and limits of agreement (LOAs) of the Bland–Altman analysis of the calculated values for FFMmHH and FFMDXA were 0.958 and −4.369–4.343 kg, respectively, for hand-to-foot BIA model measurements for men; the FFM (FFMmHF) and FFMDXA were 0.958 and −4.356–4.375 kg, respectively. The hand-to-hand BIA model estimating equation for female participants was FFMFHH = 0.615 h2/ZHH − 0.144 year + 0.132 weight + 16.507 (r2 = 0.870, SEE = 1.884 kg, n = 201); the three mean validated correlation coefficient and LOA for the hand-to-foot BIA model measurements for female participants (FFMFHH and FFMDXA) were 0.929 and −3.880–3.886 kg, respectively. The FFMHF and FFMDXA were 0.942 and −3.511–3.489 kg, respectively. The results of both hand-to-hand and hand-to-foot BIA models demonstrated similar reliability, and the hand-to-hand BIA models are practical for assessing FFM.
- Open Access
- 6 February 2013
- Published by Springer Nature in Nutrition Journal
- Vol. 12 (1) , 21
The novel application of artificial neural network on bioelectrical impedance analysis to assess the body composition in elderly
Background: This study aims to improve accuracy of Bioelectrical Impedance Analysis (BIA) prediction equations for estimating fat free mass (FFM) of the elderly by using non-linear Back Propagation Artificial Neural Network (BP-ANN) model and to compare the predictive accuracy with the linear regression model by using energy dual X-ray absorptiometry (DXA) as reference method. Methods: A total of 88 Taiwanese elderly adults were recruited in this study as subjects. Linear regression equations and BP-ANN prediction equation were developed using impedances and other anthropometrics for predicting the reference FFM measured by DXA (FFMDXA) in 36 male and 26 female Taiwanese elderly adults. The FFM estimated by BIA prediction equations using traditional linear regression model (FFMLR) and BP-ANN model (FFMANN) were compared to the FFMDXA. The measuring results of an additional 26 elderly adults were used to validate than accuracy of the predictive models. Results: The results showed the significant predictors were impedance, gender, age, height and weight in developed FFMLR linear model (LR) for predicting FFM (coefficient of determination, r2 = 0.940; standard error of estimate (SEE) = 2.729 kg; root mean square error (RMSE) = 2.571kg, P < 0.001). The above predictors were set as the variables of the input layer by using five neurons in the BP-ANN model (r2 = 0.987 with a SD = 1.192 kg and relatively lower RMSE = 1.183 kg), which had greater (improved) accuracy for estimating FFM when compared with linear model. The results showed a better agreement existed between FFMANN and FFMDXA than that between FFMLR and FFMDXA. Conclusion: When compared the performance of developed prediction equations for estimating reference FFMDXA, the linear model has lower r2 with a larger SD in predictive results than that of BP-ANN model, which indicated ANN model is more suitable for estimating FFM.
- 6 February 2013
- Published by Springer Nature in Nutrition Journal
- Vol. 12 (1) , 21
Open AccessThe novel application of artificial neural network on bioelectrical impedance analysis to assess the body composition in elderly
Background: This study aims to improve accuracy of Bioelectrical Impedance Analysis (BIA) prediction equations for estimating fat free mass (FFM) of the elderly by using non-linear Back Propagation Artificial Neural Network (BP-ANN) model and to compare the predictive accuracy with the linear regression model by using energy dual X-ray absorptiometry (DXA) as reference method. Methods: A total of 88 Taiwanese elderly adults were recruited in this study as subjects. Linear regression equations and BP-ANN prediction equation were developed using impedances and other anthropometrics for predicting the reference FFM measured by DXA (FFMDXA) in 36 male and 26 female Taiwanese elderly adults. The FFM estimated by BIA prediction equations using traditional linear regression model (FFMLR) and BP-ANN model (FFMANN) were compared to the FFMDXA. The measuring results of an additional 26 elderly adults were used to validate than accuracy of the predictive models. Results: The results showed the significant predictors were impedance, gender, age, height and weight in developed FFMLR linear model (LR) for predicting FFM (coefficient of determination, r2 = 0.940; standard error of estimate (SEE) = 2.729 kg; root mean square error (RMSE) = 2.571kg, P < 0.001). The above predictors were set as the variables of the input layer by using five neurons in the BP-ANN model (r2 = 0.987 with a SD = 1.192 kg and relatively lower RMSE = 1.183 kg), which had greater (improved) accuracy for estimating FFM when compared with linear model. The results showed a better agreement existed between FFMANN and FFMDXA than that between FFMLR and FFMDXA. Conclusion: When compared the performance of developed prediction equations for estimating reference FFMDXA, the linear model has lower r2 with a larger SD in predictive results than that of BP-ANN model, which indicated ANN model is more suitable for estimating FFM.