A Sensitive Micro Conductometric Ethanol Sensor Based on an Alcohol Dehydrogenase-Gold Nanoparticle Chitosan Composite
Authors:
- Anis MadaciAMAnis Madaci
- Patcharapan SuwanninPSPatcharapan Suwannin
- Guy RaffinGRGuy Raffin
- Marie HangouetMHMarie Hangouet
- Marie MartinMMMarie Martin
- Hana FerkousHana Ferkous
- Abderrazak BouzidABAbderrazak Bouzid
- Joan BausellsJoan Bausells
- Abdelhamid ElaissariAbdelhamid Elaissari
- Abdelhamid ErrachidAbdelhamid Errachid
- Nicole Jaffrezic-RenaultNicole Jaffrezic-Renault
Open Access
- 12 August 2023
- journal article
- research article
- Published by MDPI AG in Nanomaterials
- Vol. 13 (16) , 2316
Abstract
In this paper, a microconductometric sensor has been designed, based on a chitosan composite including alcohol dehydrogenase—and its cofactor—and gold nanoparticles, and was calibrated by differential measurements in the headspace of aqueous solutions of ethanol. The role of gold nanoparticles (GNPs) was crucial in improving the analytical performance of the ethanol sensor in terms of response time, sensitivity, selectivity, and reproducibility. The response time was reduced to 10 s, compared to 21 s without GNPs. The sensitivity was 416 µS/cm (v/v%)−1 which is 11.3 times higher than without GNPs. The selectivity factor versus methanol was 8.3, three times higher than without GNPs. The relative standard deviation (RSD) obtained with the same sensor was 2%, whereas it was found to be 12% without GNPs. When the air from the operator’s mouth was analyzed just after rinsing with an antiseptic mouthwash, the ethanol content was very high (3.5 v/v%). The background level was reached only after rinsing with water.Keywords
Funding Information
- Pack Ambition International Project (#246413)
- IRP NARES (#246413)
- PHC Maghreb EMBISALIM (#246413)
- Campus France (#246413)
This publication has 29 references indexed in Scilit:
- Highly selective gas sensor arrays based on thermally reduced graphene oxideNanoscale, 2013
- Study on nicotinamide adenine dinucleotide adsorbed at nano-boehmite/water and nano-corundum/water interfacesColloids and Surfaces B: Biointerfaces, 2013
- Amperometric enzyme electrodes for the determination of volatile alcohols in the headspace above fruit and vegetable juicesMicrochimica Acta, 2012
- Gas-Sensitive Photoconductivity of Porphyrin-Functionalized ZnO NanorodsThe Journal of Physical Chemistry C, 2012
- Analysis of volatile alcohols in apple juices by an electrochemical biosensor measuring in the headspace above the liquidSensors and Actuators B: Chemical, 2011
- Identification and quantification of different vapours using a single polymer chemoresistor and the novel dual transient temperature modulation techniqueSensors and Actuators B: Chemical, 2009
- Modelling of urea-EnFETs for haemodialysis applicationsSensors and Actuators B: Chemical, 2008
- Determination of breath alcohol using a differential-type amperometric biosensor based on alcohol dehydrogenaseAnalytica Chimica Acta, 1999
- Model of an immobilized enzyme conductimetric urea biosensorBiosensors and Bioelectronics, 1996
- A study of the nucleation and growth processes in the synthesis of colloidal goldDiscussions of the Faraday Society, 1951