Anis Madaci
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Anis Madaci has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Abdelhamid Elaissari
Université Lyon-1
1 shared publication - Abdelhamid Errachid
Institut des Sciences Analytiques (ISA), Université Claude Bernard Lyon 1, 5 Rue de la Doua, 69100 Lyon, France
1 shared publication - Abderrazak Bouzid
Materials and Electronic Systems Laboratory (LMSE), University of Bordj Bou Arréridj, El-Anasser 34030, Bordj Bou Arréridj, Algeria
1 shared publication - Guy Raffin
Université Claude Bernard Lyon 1, CNRS, Institut des Sciences Analytiques, UMR 5280, 69100, Villeurbanne, France
1 shared publication - Hana Ferkous
Laboratoire de Génie mécanique et Matériaux, Faculté de Technologie, Université de 20 août 1955 de Skikda, Skikda 21000, Algeria
1 shared publication - Joan Bausells
Institute of Microelectronics of Barcelona (IMB-CNM, CSIC), Campus UAB, 08193 Bellaterra, Spain
1 shared publication
Latest Publications
- Open Access
- 12 August 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (16) , 2316
A Sensitive Micro Conductometric Ethanol Sensor Based on an Alcohol Dehydrogenase-Gold Nanoparticle Chitosan Composite
In this paper, a microconductometric sensor has been designed, based on a chitosan composite including alcohol dehydrogenase—and its cofactor—and gold nanoparticles, and was calibrated by differential measurements in the headspace of aqueous solutions of ethanol. The role of gold nanoparticles (GNPs) was crucial in improving the analytical performance of the ethanol sensor in terms of response time, sensitivity, selectivity, and reproducibility. The response time was reduced to 10 s, compared to 21 s without GNPs. The sensitivity was 416 µS/cm (v/v%)−1 which is 11.3 times higher than without GNPs. The selectivity factor versus methanol was 8.3, three times higher than without GNPs. The relative standard deviation (RSD) obtained with the same sensor was 2%, whereas it was found to be 12% without GNPs. When the air from the operator’s mouth was analyzed just after rinsing with an antiseptic mouthwash, the ethanol content was very high (3.5 v/v%). The background level was reached only after rinsing with water.
- 12 August 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (16) , 2316
Open AccessA Sensitive Micro Conductometric Ethanol Sensor Based on an Alcohol Dehydrogenase-Gold Nanoparticle Chitosan Composite
In this paper, a microconductometric sensor has been designed, based on a chitosan composite including alcohol dehydrogenase—and its cofactor—and gold nanoparticles, and was calibrated by differential measurements in the headspace of aqueous solutions of ethanol. The role of gold nanoparticles (GNPs) was crucial in improving the analytical performance of the ethanol sensor in terms of response time, sensitivity, selectivity, and reproducibility. The response time was reduced to 10 s, compared to 21 s without GNPs. The sensitivity was 416 µS/cm (v/v%)−1 which is 11.3 times higher than without GNPs. The selectivity factor versus methanol was 8.3, three times higher than without GNPs. The relative standard deviation (RSD) obtained with the same sensor was 2%, whereas it was found to be 12% without GNPs. When the air from the operator’s mouth was analyzed just after rinsing with an antiseptic mouthwash, the ethanol content was very high (3.5 v/v%). The background level was reached only after rinsing with water.