FReSCO: Flow Reconstruction and Segmentation for low‐latency Cardiac Output monitoring using deep artifact suppression and segmentation
Open Access
- 4 July 2022
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (5) , 2179-2189
Abstract
Purpose Real-time monitoring of cardiac output (CO) requires low-latency reconstruction and segmentation of real-time phase-contrast MR, which has previously been difficult to perform. Here we propose a deep learning framework for "FReSCO" (Flow Reconstruction and Segmentation for low latency Cardiac Output monitoring). Methods Deep artifact suppression and segmentation U-Nets were independently trained. Breath-hold spiral phase-contrast MR data (N = 516) were synthetically undersampled using a variable-density spiral sampling pattern and gridded to create aliased data for training of the artifact suppression U-net. A subset of the data (N = 96) was segmented and used to train the segmentation U-net. Real-time spiral phase-contrast MR was prospectively acquired and then reconstructed and segmented using the trained models (FReSCO) at low latency at the scanner in 10 healthy subjects during rest, exercise, and recovery periods. Cardiac output obtained via FReSCO was compared with a reference rest CO and rest and exercise compressed-sensing CO. Results The FReSCO framework was demonstrated prospectively at the scanner. Beat-to-beat heartrate, stroke volume, and CO could be visualized with a mean latency of 622 ms. No significant differences were noted when compared with reference at rest (bias = -0.21 +/- 0.50 L/min, p = 0.246) or compressed sensing at peak exercise (bias = 0.12 +/- 0.48 L/min, p = 0.458). Conclusions The FReSCO framework was successfully demonstrated for real-time monitoring of CO during exercise and could provide a convenient tool for assessment of the hemodynamic response to a range of stressors.Keywords
All Related Versions
Funding Information
- British Heart Foundation (NH/18/1/33511, S032290)
- UK Research and Innovation (MR/S032290/1)
This publication has 26 references indexed in Scilit:
- Heart rate variability and stroke volume variability to detect central hypovolemia during spontaneous breathing and supported ventilation in young, healthy volunteersPhysiological Measurement, 2015
- Real‐time flow MRI of the aorta at a resolution of 40 msecJournal of Magnetic Resonance Imaging, 2013
- Spiral trajectory design: A flexible numerical algorithm and base analytical equationsMagnetic Resonance in Medicine, 2013
- Gadgetron: An open source framework for medical image reconstructionMagnetic Resonance in Medicine, 2012
- Real‐time flow with fast GPU reconstruction for continuous assessment of cardiac outputJournal of Magnetic Resonance Imaging, 2012
- Rapid Flow Assessment of Congenital Heart Disease with High-Spatiotemporal-Resolution Gated Spiral Phase-Contrast MR ImagingRadiology, 2011
- Automatic segmentation propagation of the aorta in real‐time phase contrast MRI using nonrigid registrationJournal of Magnetic Resonance Imaging, 2010
- Supine Bicycle Stress Echocardiography: Peak Exercise Imaging is Superior to Postexercise ImagingJournal of the American Society of Echocardiography, 1993
- Impedance cardiography for cardiac output measurement: An evaluation of accuracy and limitationsEuropean Heart Journal, 1990
- Adaptive histogram equalization and its variationsComputer Vision, Graphics, and Image Processing, 1987