Visual Improvement With Wavefront-Guided Scleral Lenses for Irregular Corneal Astigmatism
Authors:
- John D. O.D. GellesJGJohn D. O.D. Gelles
- Becky O.D. SuBSBecky O.D. Su
- David KellyDKDavid Kelly
- Nicolas B.S. BrownNBNicolas B.S. Brown
- Jenny O.D. WongJWJenny O.D. Wong
- Geunyoung YoonGYGeunyoung Yoon
- Travis O.D. PfeiferTPTravis O.D. Pfeifer
- Cameron B.S. ErdmanCECameron B.S. Erdman
- Peter S. HershPHPeter S. Hersh
- Steven A. GreensteinSGSteven A. Greenstein
Open Access
- 10 December 2024
- journal article
- research article
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 51 (2) , 58-64
Abstract
Purpose: To report interim results of a single center, randomized, double-blind, crossover-controlled clinical trial comparing wavefront-guided (wfg) scleral lenses (SLs) to traditional scleral lenses (tSLs) for patients with a history of irregular corneal astigmatism (ICA). Methods: Thirty-one ICA eyes of 18 participants were reviewed, 23 with keratoconus, six postcorneal refractive ectasia, and two postpenetrating keratoplasty. Patients with corneal or lens opacities were not excluded from participating. Participants underwent a diagnostic lens-based fitting with a tSL with standard spherocylindrical optics. Once the tSL was finalized, a comprehensive wavefront aberrometer-based system was used to capture the residual aberration of the tSL under scotopic conditions without pharmacologic dilation, and these data were used to create a wfgSL. Once the tSL and wgfSL were finalized, a double-blinded, randomized, crossover was conducted where the participants received lens A (tSL or wgfSL) or lens B (the alternative), each worn for a 4±1 week interval. Measurements of the visual acuity (VA) and total higher-order root mean squared (HORMS) were recorded at each interval under controlled lighting conditions. At the final visit, patient subjective preference for lens A or lens B was recorded. Results: The average HORMS for a fixed 5-mm pupil was 0.68±0.31 μm for tSL and 0.29±0.18 μm for wfgSL. Wavefront-guided SL provided an average HORMS improvement of 56% (PP<0.01). Seventy-one percent of eyes showed one line or greater improvement, 26% showed no improvement, and 3% showed a reduction of VA with the wfgSL. The average VA with tSL was 0.14±0.16 logMAR and 0.03±0.11 logMAR for wfgSL. Seventeen of 18 patients subjectively preferred wfgSL. Conclusion: In eyes with ICA, wfgSL reduced HORMS and improved VA when compared with tSL. Patients subjectively preferred wfgSL to tSL. These interim results demonstrate the feasibility and generalizability of wfgSL in a typical clinical practice environment.Keywords
This publication has 29 references indexed in Scilit:
- Corneal tissue addition keratoplasty: new intrastromal inlay procedure for keratoconus using femtosecond laser–shaped preserved corneal tissueJournal of Cataract & Refractive Surgery, 2023
- Ocular Impression-Based Scleral Lens With Wavefront-Guided Optics for Visual Improvement in KeratoconusEye & Contact Lens: Science & Clinical Practice, 2022
- Avoiding penetrating keratoplasty in severe keratoconus using a wavefront-guided scleral lensClinical and Experimental Optometry, 2021
- Alignment of a wavefront-guided scleral lens correction in the presence of a lens capsulotomyContact Lens and Anterior Eye, 2020
- Do Polymer Coatings Change the Aberrations of Conventional and Wavefront‐guided Scleral Lenses?Optometry and Vision Science, 2020
- Comparison of Wavefront‐guided and Best Conventional Scleral Lenses after Habituation in Eyes with Corneal EctasiaOptometry and Vision Science, 2019
- Demographic Characteristics and Prescribing Patterns of Scleral Lens Fitters: The SCOPE StudyEye & Contact Lens: Science & Clinical Practice, 2018
- Enhanced neural function in highly aberrated eyes following perceptual learning with adaptive opticsVision Research, 2017
- A Comparison of Three Methods to Increase Scleral Contact Lens On-Eye StabilityEye & Contact Lens: Science & Clinical Practice, 2015
- Wavefront‐Guided Scleral Lens Correction in KeratoconusOptometry and Vision Science, 2014