Steven A. Greenstein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Steven A. Greenstein has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Peter S. Hersh
Cornea and Laser Eye Institute (S.A.G., A.S.Y., A.A., D.C., N.G., B.S., P.S.H., J.D.G.) Teaneck, NJ; and Department of Ophthalmology (S.A.G., P.W., P.S.H., J.D.G.), Rutgers New Jersey Medical School, Newark, NJ
6 shared publications- Peter S. Hersh
Cornea and Laser Eye Institute-Hersh Vision Group, CLEI Center for Keratoconus, Teaneck, New Jersey, USA; Department of Ophthalmology, Rutgers-New Jersey Medical School, Newark, New Jersey, USA
5 shared publications - Austin S. Yu
Department of Ophthalmology, Drexel University College of Medicine, Philadelphia, Pennsylvania, USA
4 shared publications - John D. O.D. Gelles
Cornea and Laser Eye Institute-CLEI Center for Keratoconus (J.D.G., B.S., T.P., C.E., P.S.H., S.A.G.), Teaneck, NJ; Department of Ophthalmology (J.D.G., D.K., P.S.H., S.A.G.), Rutgers-New Jersey Medical School, Newark, NJ; TX; OVITZ Corporation (N.B., J.W.), Rochester, NY; College of Optometry (G.Y.), University of Houston, Houston, TX
4 shared publications John D. O.D. Gelles
Cornea and Laser Eye Institute (S.A.G., A.S.Y., A.A., D.C., N.G., B.S., P.S.H., J.D.G.) Teaneck, NJ; and Department of Ophthalmology (S.A.G., P.W., P.S.H., J.D.G.), Rutgers New Jersey Medical School, Newark, NJ
3 shared publicationsBecky O.D. Su
Cornea and Laser Eye Institute (S.A.G., A.S.Y., A.A., D.C., N.G., B.S., P.S.H., J.D.G.) Teaneck, NJ; and Department of Ophthalmology (S.A.G., P.W., P.S.H., J.D.G.), Rutgers New Jersey Medical School, Newark, NJ
2 shared publications
Latest Publications
- 20 August 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Subjective patient perceptions of cataract and refractive surgery in an online forum
Online social media discussions offer insight into patient experiences with refractive and cataract surgery. This retrospective cross-sectional study...
- 20 August 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Subjective patient perceptions of cataract and refractive surgery in an online forum
Online social media discussions offer insight into patient experiences with refractive and cataract surgery. This retrospective cross-sectional study...
- Open Access
- 5 January 2026
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 52 (3) , 103-104
Revised Calculation of the Prevalence of Keratoconus Based on Updated Scheimpflug Corneal Tomography Metrics in a Pediatric Population From a Chicago-Based School Age Vision Clinic
- 5 January 2026
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 52 (3) , 103-104
Open AccessRevised Calculation of the Prevalence of Keratoconus Based on Updated Scheimpflug Corneal Tomography Metrics in a Pediatric Population From a Chicago-Based School Age Vision Clinic
- Open Access
- 10 December 2024
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 51 (2) , 58-64
Visual Improvement With Wavefront-Guided Scleral Lenses for Irregular Corneal Astigmatism
Purpose: To report interim results of a single center, randomized, double-blind, crossover-controlled clinical trial comparing wavefront-guided (wfg) scleral lenses (SLs) to traditional scleral lenses (tSLs) for patients with a history of irregular corneal astigmatism (ICA). Methods: Thirty-one ICA eyes of 18 participants were reviewed, 23 with keratoconus, six postcorneal refractive ectasia, and two postpenetrating keratoplasty. Patients with corneal or lens opacities were not excluded from participating. Participants underwent a diagnostic lens-based fitting with a tSL with standard spherocylindrical optics. Once the tSL was finalized, a comprehensive wavefront aberrometer-based system was used to capture the residual aberration of the tSL under scotopic conditions without pharmacologic dilation, and these data were used to create a wfgSL. Once the tSL and wgfSL were finalized, a double-blinded, randomized, crossover was conducted where the participants received lens A (tSL or wgfSL) or lens B (the alternative), each worn for a 4±1 week interval. Measurements of the visual acuity (VA) and total higher-order root mean squared (HORMS) were recorded at each interval under controlled lighting conditions. At the final visit, patient subjective preference for lens A or lens B was recorded. Results: The average HORMS for a fixed 5-mm pupil was 0.68±0.31 μm for tSL and 0.29±0.18 μm for wfgSL. Wavefront-guided SL provided an average HORMS improvement of 56% (PP<0.01). Seventy-one percent of eyes showed one line or greater improvement, 26% showed no improvement, and 3% showed a reduction of VA with the wfgSL. The average VA with tSL was 0.14±0.16 logMAR and 0.03±0.11 logMAR for wfgSL. Seventeen of 18 patients subjectively preferred wfgSL. Conclusion: In eyes with ICA, wfgSL reduced HORMS and improved VA when compared with tSL. Patients subjectively preferred wfgSL to tSL. These interim results demonstrate the feasibility and generalizability of wfgSL in a typical clinical practice environment.
- 10 December 2024
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 51 (2) , 58-64
Open AccessVisual Improvement With Wavefront-Guided Scleral Lenses for Irregular Corneal Astigmatism
Purpose: To report interim results of a single center, randomized, double-blind, crossover-controlled clinical trial comparing wavefront-guided (wfg) scleral lenses (SLs) to traditional scleral lenses (tSLs) for patients with a history of irregular corneal astigmatism (ICA). Methods: Thirty-one ICA eyes of 18 participants were reviewed, 23 with keratoconus, six postcorneal refractive ectasia, and two postpenetrating keratoplasty. Patients with corneal or lens opacities were not excluded from participating. Participants underwent a diagnostic lens-based fitting with a tSL with standard spherocylindrical optics. Once the tSL was finalized, a comprehensive wavefront aberrometer-based system was used to capture the residual aberration of the tSL under scotopic conditions without pharmacologic dilation, and these data were used to create a wfgSL. Once the tSL and wgfSL were finalized, a double-blinded, randomized, crossover was conducted where the participants received lens A (tSL or wgfSL) or lens B (the alternative), each worn for a 4±1 week interval. Measurements of the visual acuity (VA) and total higher-order root mean squared (HORMS) were recorded at each interval under controlled lighting conditions. At the final visit, patient subjective preference for lens A or lens B was recorded. Results: The average HORMS for a fixed 5-mm pupil was 0.68±0.31 μm for tSL and 0.29±0.18 μm for wfgSL. Wavefront-guided SL provided an average HORMS improvement of 56% (PP<0.01). Seventy-one percent of eyes showed one line or greater improvement, 26% showed no improvement, and 3% showed a reduction of VA with the wfgSL. The average VA with tSL was 0.14±0.16 logMAR and 0.03±0.11 logMAR for wfgSL. Seventeen of 18 patients subjectively preferred wfgSL. Conclusion: In eyes with ICA, wfgSL reduced HORMS and improved VA when compared with tSL. Patients subjectively preferred wfgSL to tSL. These interim results demonstrate the feasibility and generalizability of wfgSL in a typical clinical practice environment.
- Open Access
- 7 March 2024
- Published by Elsevier in Advances in Ophthalmology Practice and Research
- Vol. 4 (2) , 78-83
Application of sentiment and word frequency analysis of physician review sites to evaluate refractive surgery care
- 7 March 2024
- Published by Elsevier in Advances in Ophthalmology Practice and Research
- Vol. 4 (2) , 78-83
Open AccessApplication of sentiment and word frequency analysis of physician review sites to evaluate refractive surgery care
- 28 August 2023
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 49 (10) , 428-432
Correlation of Manifest Refraction and Simulated Keratometry to Tomography Characteristics in Patients With Keratoconus
Objectives: To report on baseline refractive and keratometric values and their correlation with tomographic characteristics of eyes with keratoconus (KC). Methods: Retrospective chart review of patients treated in a single-center cornea and refractive surgery practice. Baseline topographic measurements were reviewed for 1,012 keratoconic eyes of 586 patients between 2008 and 2018. The manifest refraction, thinnest pachymetry (Pthin), corneal astigmatism (Kastig), and the maximum (Kmax), steep (Ksteep), flat (Kflat), and mean (Kmean) keratometry were analyzed. The location of Kmax (x, y) was used to determine central (5 mm) cone locations. Results: In the entire cohort, the mean manifest sphere was −2.2±4.4 diopters (D) and the cylinder was −3.2±2.3 D. In total, 48.6% of patients had against the rule (ATR) manifest astigmatism (Mastig). The average Kastig was 3.8±2.7 D, and unlike the manifest axis, 50.2% of patients had with the rule (WTR) Kastig. Patients with a Kmax less than 50 D had an Mastig of −1.9±1.6 D, 45.9% of which was ATR Mastig. With respect to baseline tomography measurements, Kmax, Ksteep, Kflat, and Kmean were 58.0±9.4, 50.6±6.5, 46.8±5.9, and 48.6±6.1 D, respectively. There was a weak correlation between Kmax and simulated keratometry (Ksteep, Kflat, and Kmean) for patients with a Kmax less than 60 D. Conclusions: Simulated keratometry is poorly correlated with KC severity until the disease is more severe. Mastig ≥2 D and ATR Mastig were correlated with KC at all levels of severity. Mastig ≥2 D and ATR Mastig may serve as a simple, inexpensive, and widely available indicator for topographic analysis to identify possible KC and suggest further workup; however, further prospective studies are needed to confirm its utility.
- 28 August 2023
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 49 (10) , 428-432
Correlation of Manifest Refraction and Simulated Keratometry to Tomography Characteristics in Patients With Keratoconus
Objectives: To report on baseline refractive and keratometric values and their correlation with tomographic characteristics of eyes with keratoconus (KC). Methods: Retrospective chart review of patients treated in a single-center cornea and refractive surgery practice. Baseline topographic measurements were reviewed for 1,012 keratoconic eyes of 586 patients between 2008 and 2018. The manifest refraction, thinnest pachymetry (Pthin), corneal astigmatism (Kastig), and the maximum (Kmax), steep (Ksteep), flat (Kflat), and mean (Kmean) keratometry were analyzed. The location of Kmax (x, y) was used to determine central (5 mm) cone locations. Results: In the entire cohort, the mean manifest sphere was −2.2±4.4 diopters (D) and the cylinder was −3.2±2.3 D. In total, 48.6% of patients had against the rule (ATR) manifest astigmatism (Mastig). The average Kastig was 3.8±2.7 D, and unlike the manifest axis, 50.2% of patients had with the rule (WTR) Kastig. Patients with a Kmax less than 50 D had an Mastig of −1.9±1.6 D, 45.9% of which was ATR Mastig. With respect to baseline tomography measurements, Kmax, Ksteep, Kflat, and Kmean were 58.0±9.4, 50.6±6.5, 46.8±5.9, and 48.6±6.1 D, respectively. There was a weak correlation between Kmax and simulated keratometry (Ksteep, Kflat, and Kmean) for patients with a Kmax less than 60 D. Conclusions: Simulated keratometry is poorly correlated with KC severity until the disease is more severe. Mastig ≥2 D and ATR Mastig were correlated with KC at all levels of severity. Mastig ≥2 D and ATR Mastig may serve as a simple, inexpensive, and widely available indicator for topographic analysis to identify possible KC and suggest further workup; however, further prospective studies are needed to confirm its utility.
- 25 August 2023
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 49 (11) , 505-507
Less Complex Contact Lens Required for a Patient With Keratoconus After Topography-Guided Photorefractive Keratectomy
In this report, we discuss contact lens (CL) fitting in a patient with a history of keratoconus (KC), before and after undergoing topography-guided photorefractive keratectomy (TG PRK). Before TG PRK, the patient failed multiple CL modalities and reported difficulty with his habitual CLs and inadequate spectacle-corrected visual acuity to perform his activities of daily living. In this case, a collaborative, comprehensive approach to visual management in a patient with KC was used, and after TG PRK was performed to improve his corneal contour and symmetry, our patient was fit with a standard soft CL and additionally had improved spectacle-corrected visual acuity.
- 25 August 2023
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 49 (11) , 505-507
Less Complex Contact Lens Required for a Patient With Keratoconus After Topography-Guided Photorefractive Keratectomy
In this report, we discuss contact lens (CL) fitting in a patient with a history of keratoconus (KC), before and after undergoing topography-guided photorefractive keratectomy (TG PRK). Before TG PRK, the patient failed multiple CL modalities and reported difficulty with his habitual CLs and inadequate spectacle-corrected visual acuity to perform his activities of daily living. In this case, a collaborative, comprehensive approach to visual management in a patient with KC was used, and after TG PRK was performed to improve his corneal contour and symmetry, our patient was fit with a standard soft CL and additionally had improved spectacle-corrected visual acuity.
- 8 August 2023
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 49 (10) , 411-416
Long-Term Outcomes After Corneal Cross-linking for Progressive Keratoconus and Corneal Ectasia: A 10-Year Follow-Up of the Pivotal Study
Objectives: To report on the topographic and visual outcomes 10 years after corneal cross-linking in patients with progressive keratoconus and corneal ectasia after refractive surgery. Methods: Cross-sectional cohort study of an original, prospective, randomized, clinical trial. Patients treated in a single center cornea and refractive surgery practice as part of the U.S. pivotal trials, which led to the Food and Drug Administration approval of corneal cross-linking, were recruited for a 10-year follow-up examination. LogMar lines (LL) of uncorrected visual acuity (UCVA) and best spectacle–-corrected visual acuity (BSCVA), maximum keratometry, and thinnest pachymetry were evaluated. In addition, the Belin ABCD progression display was used to determine progression (95% confidence interval) of the anterior curvature, posterior curvature, and corneal thickness of each individual eye included. Results: Nineteen eyes of 13 patients treated with standard cross-linking returned for a 10-year follow-up examination. Mean maximum keratometry changed from 58.2±12.0 diopters (D) to 58.3±10.1 D, thinnest pachymetry changed from 440.6±51.6 µm to 442.3±54.4 μm, UCVA changed from 0.79±0.42 LL to 0.86±0.46 LL, and BSCVA changed from 0.38±0.26 LL to 0.33±0.34 LL, 10 years after cross-linking. Individually, 68.5% of the entire cohort, 81.8% of keratoconus eyes, and 50% of eyes with corneal ectasia remained topographically stable 10 years after standard cross-linking. Conclusions: In the entire cohort, visual acuity and topography remained stable 10 years after cross-linking. Over the long-term, eyes with keratoconus seem to be more stable than those with corneal ectasia.
- 8 August 2023
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 49 (10) , 411-416
Long-Term Outcomes After Corneal Cross-linking for Progressive Keratoconus and Corneal Ectasia: A 10-Year Follow-Up of the Pivotal Study
Objectives: To report on the topographic and visual outcomes 10 years after corneal cross-linking in patients with progressive keratoconus and corneal ectasia after refractive surgery. Methods: Cross-sectional cohort study of an original, prospective, randomized, clinical trial. Patients treated in a single center cornea and refractive surgery practice as part of the U.S. pivotal trials, which led to the Food and Drug Administration approval of corneal cross-linking, were recruited for a 10-year follow-up examination. LogMar lines (LL) of uncorrected visual acuity (UCVA) and best spectacle–-corrected visual acuity (BSCVA), maximum keratometry, and thinnest pachymetry were evaluated. In addition, the Belin ABCD progression display was used to determine progression (95% confidence interval) of the anterior curvature, posterior curvature, and corneal thickness of each individual eye included. Results: Nineteen eyes of 13 patients treated with standard cross-linking returned for a 10-year follow-up examination. Mean maximum keratometry changed from 58.2±12.0 diopters (D) to 58.3±10.1 D, thinnest pachymetry changed from 440.6±51.6 µm to 442.3±54.4 μm, UCVA changed from 0.79±0.42 LL to 0.86±0.46 LL, and BSCVA changed from 0.38±0.26 LL to 0.33±0.34 LL, 10 years after cross-linking. Individually, 68.5% of the entire cohort, 81.8% of keratoconus eyes, and 50% of eyes with corneal ectasia remained topographically stable 10 years after standard cross-linking. Conclusions: In the entire cohort, visual acuity and topography remained stable 10 years after cross-linking. Over the long-term, eyes with keratoconus seem to be more stable than those with corneal ectasia.
- 1 July 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (7) , 740-746
Corneal tissue addition keratoplasty: new intrastromal inlay procedure for keratoconus using femtosecond laser–shaped preserved corneal tissue
Purpose: To report results of Corneal Tissue Addition Keratoplasty (CTAK) for keratoconus (KC) and ectasia after laser in situ keratomileusis. Setting: Cornea and refractive surgery practice. Design: Single center, prospective, open label clinical trial. Methods: 21 eyes of 18 patients underwent CTAK. A tissue inlay of preserved corneal tissue was cut to customized specifications with a femtosecond laser and placed in a laser-created channel in the host cornea. Postoperative uncorrected and corrected distance visual acuity (UDVA, CDVA), manifest refraction spherical equivalent (MRSE), topographic mean keratometry (Kmean), maximum keratometry (Kmax), and the point of maximum flattening (Kmaxflat) were measured. Results: Average UDVA improved from 1.21 ± 0.35 logMAR lines (LL) (20/327) to 0.61 ± 0.25 LL (20/82) (P < .001). Average CDVA improved from 0.62 ± 0.33 LL (20/82) to 0.34 ± 0.21 LL (20/43) (P = .002), and average MRSE improved from −6.25 ± 5.45 diopters (D) to −1.61 ± 3.33 D (P = .002). Individually, 20 eyes (95.2%) gained more than 2 lines of UDVA, with 10 eyes (47.6%) gaining more than 6 lines, and no eyes worsening. 12 eyes (57.1%) gained at least 2 lines of CDVA, with 1 eye worsening by more than 2 lines. At 6 months, average Kmean flattened by −8.44 D (P = .002), Kmax flattened by −6.91 D (P = .096), and mean Kmaxflat was −16.03 D. Conclusions: CTAK is a promising procedure to improve visual acuity and topography in patients with KC and ectasia.
- 1 July 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (7) , 740-746
Corneal tissue addition keratoplasty: new intrastromal inlay procedure for keratoconus using femtosecond laser–shaped preserved corneal tissue
Purpose: To report results of Corneal Tissue Addition Keratoplasty (CTAK) for keratoconus (KC) and ectasia after laser in situ keratomileusis. Setting: Cornea and refractive surgery practice. Design: Single center, prospective, open label clinical trial. Methods: 21 eyes of 18 patients underwent CTAK. A tissue inlay of preserved corneal tissue was cut to customized specifications with a femtosecond laser and placed in a laser-created channel in the host cornea. Postoperative uncorrected and corrected distance visual acuity (UDVA, CDVA), manifest refraction spherical equivalent (MRSE), topographic mean keratometry (Kmean), maximum keratometry (Kmax), and the point of maximum flattening (Kmaxflat) were measured. Results: Average UDVA improved from 1.21 ± 0.35 logMAR lines (LL) (20/327) to 0.61 ± 0.25 LL (20/82) (P < .001). Average CDVA improved from 0.62 ± 0.33 LL (20/82) to 0.34 ± 0.21 LL (20/43) (P = .002), and average MRSE improved from −6.25 ± 5.45 diopters (D) to −1.61 ± 3.33 D (P = .002). Individually, 20 eyes (95.2%) gained more than 2 lines of UDVA, with 10 eyes (47.6%) gaining more than 6 lines, and no eyes worsening. 12 eyes (57.1%) gained at least 2 lines of CDVA, with 1 eye worsening by more than 2 lines. At 6 months, average Kmean flattened by −8.44 D (P = .002), Kmax flattened by −6.91 D (P = .096), and mean Kmaxflat was −16.03 D. Conclusions: CTAK is a promising procedure to improve visual acuity and topography in patients with KC and ectasia.
- 3 May 2023
- Published by Taylor & Francis in Seminars in Ophthalmology
- Vol. 38 (8) , 768-772
EQIP Quality Assessment of Refractive Surgery Resources on YouTube
To evaluate the utility of EQIP as a novel tool for determining the quality of patient information on YouTube regarding refractive eye surgery.Three searches were conducted on YouTube using “PRK ey...
- 3 May 2023
- Published by Taylor & Francis in Seminars in Ophthalmology
- Vol. 38 (8) , 768-772
EQIP Quality Assessment of Refractive Surgery Resources on YouTube
To evaluate the utility of EQIP as a novel tool for determining the quality of patient information on YouTube regarding refractive eye surgery.Three searches were conducted on YouTube using “PRK ey...
- Open Access
- 1 May 2023
- Published by SLACK, Inc. in Journal of Refractive Surgery Case Reports
- Vol. 3 (2)
Intacs and Topography-Guided Photorefractive Keratectomy for Treatment of Incomplete LASIK Flap-Induced Irregular Corneal Topography: A Case Report
- 1 May 2023
- Published by SLACK, Inc. in Journal of Refractive Surgery Case Reports
- Vol. 3 (2)
Open AccessIntacs and Topography-Guided Photorefractive Keratectomy for Treatment of Incomplete LASIK Flap-Induced Irregular Corneal Topography: A Case Report