Contactless Arrhythmia Detection and Short-Term HRV Analysis Based on a Fiber Optic Sensor
- 25 August 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Abstract
Accurate detection of premature atrial contractions (PACs) is crucial for identifying life-threatening arrhythmias. Traditional electrocardiogram (ECG) devices, which require electrodes attached to the body, often cause discomfort and are unsuitable for long-term monitoring. This paper presents a non-contact ballistocardiogram (BCG) monitoring system utilizing a fiber optic sensor (FOS) for PAC identification and short-term heart rate variability (HRV) analysis. The system employs a Mach-Zehnder interferometer (MZI), which is simple and easy to replicate, consisting of only a 1×2 coupler and a 3×3 coupler. Tiny body vibrations caused by breathing and heartbeats lead to changes in the intensity of the interference light. By detecting these changes using three photodetectors (PDs), vital sign signals can be captured. To evaluate the robustness of the PAC detection algorithm, the study introduced fixed-speed breathing at two respiratory frequencies, increasing the range of interbeat interval (IBI) variations. The correlation coefficient between BCG-derived IBI and ECG-derived IBI in subjects with PAC was 0.9475. The proposed algorithm achieved an accuracy of 94.84% in PAC detection. Additionally, the time-domain and frequency-domain results of BCG-derived HRV and ECG-derived HRV showed high correlation at respiratory rates of 6 beats per minute (bpm) and 15 bpm. The FOS-based BCG signal not only accurately identifies PACs but also facilitates HRV analysis. This proposed system is suitable for long-term, non-contact vital sign monitoring in daily life.Keywords
Funding Information
- National Natural Science Foundation of China (62401257)
- Hong Kong Polytechnic University (HKPU 1-WZ01, HKPU 1-CD8N)
This publication has 35 references indexed in Scilit:
- Heart Rate Detection from Ballistocardiogram Using Continuous Wavelet Transformation2024
- Screening for Cardiovascular Disease Risk With ECGJAMA, 2018
- The variable heart: High frequency and very low frequency correlates of depressive symptoms in children and adolescentsJournal of Affective Disorders, 2015
- Detection of heartbeat and respiration from optical interferometric signal by using wavelet transformComputer Methods and Programs in Biomedicine, 2013
- Short and longer term repeatability of ballistocardiography in a sitting position with EMFi sensorMedical & Biological Engineering & Computing, 2011
- Automatic detection of motion artifacts in the ballistocardiogram measured on a modified bathroom scaleMedical & Biological Engineering & Computing, 2010
- Heart rate variability: a reviewMedical & Biological Engineering & Computing, 2006
- Automatic detection of spiking events in EMFi sheet during sleepMedical Engineering & Physics, 2005
- Advanced Pacemaker Diagnostic Features in the Characterization of Atrial Fibrillation: Impact on Preventive Pacing AlgorithmsPacing and Clinical Electrophysiology, 2003
- Time-Domain Measurement of Heart Rate VariabilityCardiac Electrophysiology Review, 1997