Fluidic microactuation of flexible electrodes for neural recording
Authors:
- Flavia VitaleFVFlavia Vitale
- Daniel G. VercosaDVDaniel G. Vercosa
- Alexander V. RodriguezARAlexander V. Rodriguez
- Sushma Sri PamulapatiSPSushma Sri Pamulapati
- Frederik SeibtFSFrederik Seibt
- Eric LewisELEric Lewis
- J. Stephen YanJYJ. Stephen Yan
- Krishna BadhiwalaKBKrishna Badhiwala
- Mohammed AdnanMAMohammed Adnan
- Gianni Royer-CarfagniGRGianni Royer-Carfagni
- Michael BeierleinMBMichael Beierlein
- Caleb KemereCKCaleb Kemere
Preprint
Abstract
Ultra-flexible microelectrodes that can bend and flex with the natural movement of the brain reduce the inflammatory response and improve the stability of long-term neural recordings. 1-5 However, current methods to implant these highly flexible electrodes rely on temporary stiffening agents that increase the electrode size 6-10 thus aggravating neural damage during implantation, which leads to cell loss and glial activation that persists even after the stiffening agents are removed or dissolve. 11-13 A method to deliver thin, ultra-flexible electrodes deep into neural tissue without increasing the stiffness or size of the electrodes will enable minimally invasive electrical recordings from within the brain. Here we show that specially designed microfluidic devices can apply a tension force to ultra-flexible electrodes that prevents buckling without increasing the thickness or stiffness of the electrode during implantation. Additionally, these “fluidic microdrives” allow us to precisely actuate the electrode position with micron-scale accuracy. To demonstrate the efficacy of our fluidic microdrives, we used them to actuate highly flexible carbon nanotube fiber (CNTf) microelectrodes 11,14 for electrophysiology. We used this approach in three proof-of-concept experiments. First, we recorded compound action potentials in a soft model organism, the small cnidarian Hydra . Second, we targeted electrodes precisely to the thalamic reticular nucleus in brain slices and recorded spontaneous and optogenetically-evoked extracellular action potentials. Finally, we inserted electrodes more than 4 mm deep into the brain of rats and detected spontaneous individual unit activity in both cortical and subcortical regions. Compared to syringe injection, fluidic microdrives do not penetrate the brain and prevent changes in intracranial pressure by diverting fluid away from the injection site during insertion and actuation. Overall, the fluidic microdrive technology provides a robust new method to implant and actuate ultra-flexible neural electrodes.Keywords
All Related Versions
- Published version: Nano Letters, 18 (1), 326.
This publication has 54 references indexed in Scilit:
- High-throughput imaging of neuronal activity in Caenorhabditis elegansProceedings of the National Academy of Sciences of the United States of America, 2013
- High-performance neuroprosthetic control by an individual with tetraplegiaThe Lancet, 2013
- Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfacesNature Materials, 2012
- Plasma-assisted atomic layer deposition of Al2O3 and parylene C bi-layer encapsulation for chronic implantable electronicsApplied Physics Letters, 2012
- Differential Effects of Isoflurane on High-frequency and Low-frequency γ Oscillations in the Cerebral Cortex and Hippocampus in Freely Moving RatsAnesthesiology, 2011
- General Anesthesia, Sleep, and ComaThe New England journal of medicine, 2010
- Microseizures and the spatiotemporal scales of human partial epilepsyBrain, 2010
- Quantitative analysis of the tissue response to chronically implanted microwire electrodes in rat cortexBiomaterials, 2010
- Microfluidic system for on-chip high-throughput whole-animal sorting and screening at subcellular resolutionProceedings of the National Academy of Sciences, 2007
- Head regeneration in HydraDevelopmental Dynamics, 2003